DatasheetsPDF.com

MDU200 Dataheets PDF



Part Number MDU200
Manufacturers Power-One
Logo Power-One
Description Power Factor Correction
Datasheet MDU200 DatasheetMDU200 Datasheet (PDF)

MPU200/MDU200 Series Data Sheet Features • • • • • • • • • RoHS lead free solder and lead solder exempted products are available Power Factor Correction (PFC) meets EN61000-3-2 Same size, airflow, and construction as MPU150/MDU150 with over 33% more power Single-wire current sense on quad model outputs V1 and V2 Remote sense on quad model outputs V1 and V2 Current share and N+1 redundancy (standard on all models) Overtemperature, overload, and overvoltage protection Available with SAE mountings.

  MDU200   MDU200



Document
MPU200/MDU200 Series Data Sheet Features • • • • • • • • • RoHS lead free solder and lead solder exempted products are available Power Factor Correction (PFC) meets EN61000-3-2 Same size, airflow, and construction as MPU150/MDU150 with over 33% more power Single-wire current sense on quad model outputs V1 and V2 Remote sense on quad model outputs V1 and V2 Current share and N+1 redundancy (standard on all models) Overtemperature, overload, and overvoltage protection Available with SAE mountings MDU200 models have 48VDC input Description The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series, 200W of continuous output power is provided with single or multiple output units suited for distributed power or central power applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital circuitry. Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch. The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 volt DC input. www.DataSheet4U.com AC Input, Single-Output Model Selection MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 2) 200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1) PEAK OUTPUT LINE CURRENT (NOTE 2) REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 3) INITIAL SETTING ACCURACY MPU200-1012 MPU200-1024 MPU200-1048 12V 24V 48V 11.6V to 16V 22.8V to 29.2V 45V to 56V 17.0A 8.35A 4.2A 19.0A 9.4A 4.7A 0.1% 0.1% 0.1% 1% 1% 1% 1% 1% 1% 11.97V to 12.03V 23.95V to 24.05V 47.9V to 48.1V AC Input, Multiple-Output Model Selection OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 2) 200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1) ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS MODEL LINE REGULATION LOAD REGULATION RIPPLE & NOISE %Pk-Pk (NOTE 3) INITIAL SETTING ACCURACY +5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% +3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% MPU200-4530 12V 10.8V to 13.2V 8A (Note 5) 0.4% 10% 12V 10.8V to 13.2V 4A (Note 5) 0.4% 10% NOTES: 1) This product is not rated for convection applications. 2) Output currents ratings are expressed with 300 LFM forced air. 3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Total current for V1 and V2 is not to exceed 35A. 5) Total power on V3 and V4 is not to exceed 100W. 1% 1.5% 1% 1% 4.98V to 5.02V 3.28.


PM355 MDU200 MPU200


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)