4-Line Filters for Converters and Power Electronics Power line filters for three-phase systems Rated voltage 440/250 V~, 50/60 Hz Rated current 16 to 1600 A Construction ■ Four-line filter ■ Metal case ■ Threaded bushes at end faces for B84144 RF-tight installation Features ■ ■ ■ ■ ■ Low leakage current Easy to install Degree of protection up to 180 A: IP 201) Space-saving design Design based on EN 133200, UL 1283, CSA 22.2 No.8 1986 Applications ■ General-purpose www.DataSheet4U.com applic.

  B84144   B84144



Document
4-Line Filters for Converters and Power Electronics Power line filters for three-phase systems Rated voltage 440/250 V~, 50/60 Hz Rated current 16 to 1600 A Construction ■ Four-line filter ■ Metal case ■ Threaded bushes at end faces for B84144 RF-tight installation Features ■ ■ ■ ■ ■ Low leakage current Easy to install Degree of protection up to 180 A: IP 201) Space-saving design Design based on EN 133200, UL 1283, CSA 22.2 No.8 1986 Applications ■ General-purpose www.DataSheet4U.com application in power electronics ■ UPS ■ Wind farms ■ For machine tools, textile and packaging machines Terminals ■ Safe-to-touch terminal blocks for filters up to 180 A ■ Busbars for filters 250 to 1600 A Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code 1) In accordance with IEC 60529: 1989; EN 60529: 1991; DIN VDE 0470-1 274 04/02 4-Line Filters for Converters and Power Electronics Typical circuit diagram LINE L1 LOAD L1’ B84144 L2 L2’ L3 L3’ N PE N’ PE SSB1076-F Technical data Rated voltage V R Rated current I R Test voltage V P 440/250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1770 V–, 2 s (line/line) 2700 V–, 2 s (lines/case), for 16 … 50 A 2550 V–, 2 s (lines/case), for 80 … 180 A 2121 V–, 2 s (lines/case), for 250 … 1600 A 1,5 · IR for 3 min per hour or 2,5 · IR für 30 s per hour at 400 V~, 50 Hz 25/100/21 (– 25 °C/+100 °C/21 days damp heat test) in accordance with EN 60068-1 Overload capability Leakage current Ileak Climatic category 275 04/02 4-Line Filters for Converters and Power Electronics Characteristics and ordering codes IR A 16 25 36 50 80 120 150 180 250 500 1000 1600 Terminal cross section mm2 4 10 10 10 25 50 50 95 Busbars I leak mA Rtyp mΩ 10 6 3,5 1,3 0,7 0,5 0,35 0,25 0,095 0,060 0,030 0,020 PV W 8 11 14 10 13 22 24 24 18 45 90 150 Approx. weight kg 2,2 3,7 3,7 4,0 9,5 10 10 13 32 53 140 185 B84144 Ordering code < 3,5 < 3,5 < 3,5 <6 <6 <6 <6 <6 <6 <6 <6 <6 B84144-A16-R B84144-A25-R B84144-A36-R B84144-A50-R B84144-A80-R B84144-A120-R B84144-A150-R B84144-A180-R B84144-G250-S B84144-G500-S B84144-G1000-S B84144-G1600-S 276 04/02 4-Line Filters for Converters and Power Electronics Dimensional drawings B84144-A16-R 20,5±0,5 B84144 81 max. 55±0,4 36±1 PE M6 x 25 163 max. 70±0,2 12,5±0,4 1±0,1 60±0,4 86 max. 4x × M5/6 M5 /mm 6 mm tief deep 12,5±1 N L3 L2 L1 N L3 L2 L1 100±0,3 Marking LINE LOAD 5,5±0,1 141 max. Anschlussklemmen Terminal blocks 2 4 4 mm mm2 113 max. SSB1077-N B84144-A25-R … B84144-A50-R 31±0,5 91 max. 65±0,4 30±1 46±1 12,5±0,4 1±0,1 PE M6 x 25 216 max. 80±0,2 100±0,4 22,5±1 126 max. 4x tief deep × M6/6 M6 /mm 6 mm L2 L1 N L3 LINE LOAD 6,6±0,2 166 max. Anschlussklemmen Terminal blocks 2 10 mm mm 2 10 N L3 156 max. 140±0,3 Marking L2 L1 SSB1078-W 277 04/02 30±1 4-Line Filters for Converters and Power Electronics B84144-A80-R 48,5±0,5 B84144 141 max. 18±1 110±0,4 1,2±0,1 83±1 15±0,4 PE M10 x 35 300 max. 115±0,2 110±0,4 141 max. 4x × M6/6 M6 /mm 6 mm tief deep L1 L1 N LINE LOAD 6,6±0,2 221 max. N 155±0,3 Marking Terminal 25 mm 2 blocks 25 mm2 Anschlussklemmen SSB1079-5 B84144-A120-R, B84144-A150-R 54±0,5 18±1 171 max. L2 L3 L3 L2 141 max. 110±0,4 1,2±0,1 87±1 15±0,4 PE M10 x 35 348 max. 115±0,2 110±0,4 141 max. tief deep 4x × M6/6 M6 /mm 6 mm N L3 L2 L1 N L3 L2 L1 LINE LOAD 6,6±0,2 261 max. Anschlussklemmen 2 Terminal 50 mm2 50 mmblocks 155±0,3 Marking 171 max. SSB1086-M 278 04/02 55±1 55±1 4-Line Filters for Converters and Power Electronics B84144-A180-R B84144 141 max. 16±0,5 105±1 120±0,4 74±0,5 1,2±0,1 10±0,4 PE M10 x 35 404 max. 301 max. 110±0,4 141 max. 4 tief deep 4x×M6/6 M6 mm / 6 mm L1 L1 Marking LINE LOAD 6,6±0,2 82,5±0,2 82,5±0,2 Terminal blocks 95 mm2 2 Anschlussklemmen 95 mm 171 max. L2 L2 155 ±0,3 L3 N N L3 SSB1087-V 279 04/02 62±0,8 4-Line Filters for Converters and Power Electronics B84144-G250-S 4 x M8 x 7 4 x M8 x 7 B84144 350+3 190±0,5 L2 L1 110 171_ 4 L3 4,5±0,5 105±0,5 N N 4 PE M10 x 30 200±1 30 ø10,5 PE M10 x 30 ø12 L3 L2/ N L1 LINE Marking LOAD L3 24±1 L2/ N L1 230+2 260±1 24 120 15 _ 3 = 370±3 460±6 = SSB0996-A 280 04/02 285 34 N 48 89,5 4-Line Filters for Converters and Power Electronics B84144-G500-S 4 x M8 x 7 4 x M8 x 7 B84144 500 210±0,5 L2 6±0,5 150±0,5 L3 L1 N N N 6 PE M10 x 30 280±1 30 ø11 L3 L2/ N L1 LINE Marking LOAD PE M10 x 30 26 60 150 ø12 L3 30+3 L2/ N L1 280±1 250 15 +1 = 510±3 590±3 = SSB0997-I 281 04/02 305 56,5 101,5 134,5 198 _ 4 4-Line Filters for Converters and Power Electronics B84144-G1000-S 4 x M8 x 7 4 x M8 x 7 11±0,5 B84144 650+4 360±0,8 L3 240±0,8 L2 L1 78 163 211 290 _ 3 SSB0998-R N PE M12 x 30 320±1 ø14 L3 L2/ N LINE L1 Marking LOAD 40 ø12 N 8 28 N 38 PE M12 x 30 65 262 L3 L2/ N L1 50+10 400+3 440±1 465 40 = 660±3.


B84143-Vxx-R27 B84144 B84299-K33


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)