(B84142-Axxx-Sxx) 72-Line Filters
2-Line Filters for Converters in Traction Systems
Power line filters for dc systems Rated voltage 750 to 2000 V– Rated c...
Description
2-Line Filters for Converters in Traction Systems
Power line filters for dc systems Rated voltage 750 to 2000 V– Rated current 250 to 1000 A Construction
s Two-line filter s Metal case
B84142-A*-S2 ... B84142-A*-S18
Features
s Easy to install s Space-saving design s Design based on
EN 133 200, UL 1283, CSA 22.2 No.8 1986
s Optimized for long motor cables and
operation under full load Applications
s Trams, light rails s Subways
www.DataSheet4U.com
Terminals
s Busbars, tin-plated
Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Typical circuit diagram
L+ L_ LINE
L+’ L _’ LOAD
Traction Bahnseite side
Inverter Umrichter
SSB1309-8
183 03/01
2-Line Filters for Converters in Traction Systems
Technical data Rated voltage V R 750 V− (Type -S2) 1000 V− (Type -S3) 2000 V− (Type -S18)
B84142-A*-S2 ... B84142-A*-S18
Rated current IR Test voltage VP
Referred to 60 °C ambient temperature For 750 V− filters: 2000 V−, 60 s (L+/L−) 4900 V−, 60 s (L+||L−/case) 6000 V−, 2 s (L+||L−/case)
For 1000 V− filters: 2500 V−, 60 s (L+/L−) 4900 V−, 60 s (L+||L−/case) 6000 V−, 2 s (L+||L−/case) For 2000 V− filters: 4000 V−, 60 s (L+/L−) 4900 V−, 60 s (L+||L−/case) 6000 V−, 2 s (L+||L−/case) Overload capability Climatic category 1,6 · IR for 20 s or 2,0 · IR for 10 s 40/100/21 (– 40 °C/+ 100 °C/21 days damp heat test) in accordance with EN 60068-1
Characteristics and o...
Similar Datasheet