Document
RoHS Compliant
1:1 Flux Coupled Transformer 3-200MHz
Features
• • • • • • • Surface Mount 1:1 Impedance Centre tap on secondary 260°C Reflow Compatible RoHS* Compliant RoHS version of ETC1-1T and MABACT0012 Available on Tape and Reel. Reel quantity 2000
MABACT0062 V3
Schematic
Description
M/A-COM’s MABACT0062 is a 1:1 RF flux coupled transformer in a low cost, surface mount package. Ideally suited for high volume CATV/Broadband applications. This product is suitable for both 50 and 75 Ohm systems.
Case Style: SM-22
0.050 (1.27) 0.030 (0.762)
www.DataSheet4U.com
0.150 (3.81) 0.030 (0.762) 0.150 (3.81)
0.150 MAX (3.81 MAX) 0.065 (1.65)
0.030 (0.762)
0.055 0.190 (1.397) (4.83)
Pin Configuration
Pin No. 1 2 3 4 5 Function Secondary Dot Secondary centre tap Secondary Primary Primary Dot
0.100 (2.54) 0.130 (3.30) 0.030 (0.762)
Dimensions in inches [mm] Tolerance: .xx ± .02, .xxx ± .010
Ordering Information
Part Number MABACT0062 MABA-008115-CT62TB Package 2000 piece reel Customer test board
Note: Reference Application Note M513 for reel size information. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
RoHS Compliant
1:1 Flux Coupled Transformer 3-200MHz
Electrical Specifications: TA = 25°C, Z0 = 50Ω 1
Parameter
Insertion Loss
MABACT0062 V3
Test Conditions
-
Frequency
3 - 50 MHz 50 - 160 MHz 160 - 200 MHz 3 - 50 MHz 50 - 200 MHz 3 - 50 MHz 50 - 200 MHz 3 - 200 MHz 5 - 100 MHz
Units
dB dB dB dB dB º º dB dB
Min
10 15
Typ
0.2 0.5 0.8 0.02 0.06 0.2 0.5 20 25
Max
0.5 1.0 1.2 ± 0.1 ± 0.5 ± 1.5 ± 5.0 -
Amplitude Unbalance (Nominal 0dB) Phase Unbalance (Nominal 180º) Input Return Loss
Electrical Specifications: TA = 25°C, Z0 = 75Ω 1
Parameter
Insertion Loss
Test Conditions
-
Frequency
3 - 5 MHz 5 - 65 MHz 65 - 200 MHz 3 - 65 MHz 65 - 200 MHz 3 - 65 MHz 65 - 200 MHz 3 - 5MHz 5 - 65 MHz 65 - 100 MHz 100 - 200 MHz
Units
dB dB dB dB dB º º dB dB dB dB
Min
18 21 19 14
Typ
0.5 0.4 0.6 0.02 0.04 0.4 1.2 24 29 25 20
Max
1.0 0.6 1.0 ± 0.2 ± 0.3 ± 2.0 ± 5.0 -
Amplitude Unbalance (Nominal 0dB) Phase Unbalance (Nominal 180º) Input Return Loss
Absolute Maximum Ratings 1,2
Parameter Max Input Power DC current Operating Temperature Storage Temperature Absolute Maximum 250mW 240mA -40°C to +85°C -55°C to +100°C
Recommended PCB Configuration
0.065 (1.65)
0.055 0.190 (1.397) (4.83)
0.130 (3.30)
1. Exceeding any .