Document
2-Line Filters for General-Purpose Applications
Power line filters for single-phase systems Rated voltage 250 V~, 50/60 Hz Rated current 1 to 6 A Construction
s Filter with IEC connector, fuse holder
B84103
and switch
s Appliance connector as per IEC 60320 s Fuse holder 5 × 20 mm s 2-pole disconnector
Features
s Enhanced differential-mode insertion loss s For installation in instrument housings
Applications
s Medium-performance switch-mode power supplies s Industrial electronics s Measuring instruments
www.DataSheet4U.com
Terminals
s Tab connector 6,3 x 0,8 mm at output
Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Circuit diagram
LINE L
LOAD L’
IEC Connector IEC-Stecker
N
N’
SSB0207-F
196 03/01
2-Line Filters for General-Purpose Applications
Technical data Rated voltage V R Rated current IR Test voltage V P Leakage current l leak Climatic category Weight 250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1414 V–, 2 s (line/line) 2700 V–, 2 s (lines/case) < 1 mA at 230 V~, 50 Hz
B84103
In accordance with EN 60068-1 25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test) approx. 150 g
Characteristics and ordering codes IR A 1 3 6 0,33 µF (X2) + 2 × 10 nF (Y2) 0,33 µF (X2) + 2 × 10 nF (Y2) 0,33 µF (X2) + 2 × 10 nF (Y2) 2 × 9 mH + 2 × 270 µH 2 × 1,5 mH + 2 × 22 µH 2 × 0,47 mH + 2 × 8 µH B84103-S1-A10 B84103-S1-A30 B84103-S1-A60 CR LR Ordering code Approvals
565-3
× × ×
×
— —
× × ×
× = approval granted
197 03/01
2-Line Filters for General-Purpose Applications
Dimensional drawing
Mounting version II Mounting direction Mounting version I Mounting direction Tab connector
B84103
Mounting holes for mounting version I
Mounting holes for mounting version II
M3 or Ø 3,5
198 03/01
2-Line Filters for General-Purpose Applications
Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84103-S1-A10
100
SSB0210-Z
B84103
B84103-S1-A30
100
SSB0211-8
αe
dB 80
αe
dB 80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
Hz 10 8 f
0
10 4
10 5
10 6
10 7
Hz 10 8 f
B84103-S1-A60
100
SSB0212-G
αe
dB 80
60
40
20
0
10 4
10 5
10 6
10 7
Hz 10 8 f
199 03/01
Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik,.