Power line filters
2-Line Filters for General-Purpose Applications
Power line filters for single-phase systems Rated voltage 250 V~, 50/60 ...
Description
2-Line Filters for General-Purpose Applications
Power line filters for single-phase systems Rated voltage 250 V~, 50/60 Hz Rated current 1 to 6 A Construction
s Plastic case s Filter comprises current-compensated choke
B84102-K
Features
s High insertion loss
Applications
s Industrial equipment and small-size systems
Terminals
s Safe-to-touch terminal blocks
Marking Manufacturer’s www.DataSheet4U.com Marking on component: logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Circuit diagram
LINE LOAD
L
L’
N
N’
SSB0306-D
192 03/01
2-Line Filters for General-Purpose Applications
Technical data Rated voltage V R Rated current IR Test voltage V P Leakage current l leak Climatic category Weight 250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1414 V–, 2 s, (line/line) 2700 V–, 2 s, (lines/ground) at 230 V~, 50 Hz
B84102-K
In accordance with EN 60068-1 25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test) approx. 250 g
Characteristics and ordering codes IR A 1 2 × 0,22 µF (X2) + 2 × 2500 pF (Y2) 2 × 0,33 µF (X2) + 2 × 2500 pF (Y2) 2 × 0,47 µF (X2) + 2 × 2500 pF (Y2) 2 × 0,47 µF (X2) + 2 × 0,035 µF (Y2) CR LR mH 2 × 18 l leak mA < 0,5 B84102-K30 Ordering code
2
2 × 10
< 0,5
B84102-K40
4
2 × 4,7
< 0,5
B84102-K50
6
2 × 2,2
< 3,5
B84102-K160
193 03/01
2-Line Filters for General-Purpose Applications
Dimensional drawing
38,5
B84102-K
32 max.
PE M3,5 103 90±0,3 1,5
Terminal blocks 2,...