(CT0.1-P - CT0.4-P) Current Transducers
Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed, with a galvanic isol...
Description
Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed, with a galvanic isolation between the primary circuit and the secondary circuit.
IPN = ± 100..400 mA VOUT = ± 5 V
Electrical data
Primary nominal current rms IPN (mA) 100 200 400 Primary current, measuring range IPM (mA) ± 180 ± 360 ± 720 Type RoHS since date code 46129 46054 46234
Features
DC & AC earth leakage current transducer using a flux-gate principle PCB mounting ±15V power supply ±5V output @ IPN Insulated plastic case recognized
according to UL94-V0.
CT 0.1-P CT 0.2-P CT 0.4-P
VC IC RIS VOUT ROUT RL CL
Supply voltage (± 5 %) Current consumption Isolation resistance @ 500 VDC Output voltage (Analog) @ ± IPN, RL= 10kΩ , TA=25°C Output internal resistance Load resistance Capacitive loading
± 15 ± 35 > 500 ±5 < 51 ≥ 10 ≤5
V mA MΩ V Ω kΩ nF
Accuracy-Dynamic performance data
X
Advantages
<±1 %of IPN < ± 0.5 %of IPN < ± 0.05 %/K < ± 50 mV <±2 mV < ± 20 mV <±4 mV/K <±3 mV/K <±2 mV/K ≤ 20 ms ≤ 60 ms DC .. 7000 Hz DC .. 11000 Hz DC .. 18000 Hz
ε
L
TCVOUT VOE VOH
TCVOE
tr BW
Accuracy (excluding offset) @ IPN, TA = 25°C, RL = 10kΩ Linearity error (0 .. ± IPN) Temperature coefficient of VOUT (of reading) Eletrical offset voltage @ IP = 0, TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN @ IP = 0; after an excursion of 100 x IPN Temperature coefficient of VOE @ -20..+85°C CT 0.1-P CT 0.2-P CT 0.4-P Response time to 80% of IPN ste...