Document
• 1N4150UR-1 AVAILABLE IN JAN, PER MIL-PRF-19500/231 • SWITCHING DIODE • HERMETICALLY SEALED • METALLURGICALLY BONDED • DOUBLE PLUG CONSTRUCTION
JANTX, AND JANTXV
1N4150UR-1 1N3600UR CDLL4150 CDLL3600
MAXIMUM RATINGS
Junction Temperature: -65°C to +175°C Storage Temperature: -65°C to +175°C Operating Current: 300 mA @ TA = + 25°C Derating: 3.1 mA dc/°C Above TEC = + 110°C Forward Surge Current: 4A, (tp = 1µs); 0.5A (tp = 1s)
ELECTRICAL CHARACTERISTICS @ 25°C, unless otherwise speci½ed.
Type V BR IR = 10 V RWM I R1 VR = 50 V dc TA = 25°C V (pk) 50 50 µA dc 0.1 0.1 1 R2 VR = 50 V dc TA = 150°C µA dc 100 100 C VR = 0; f = 1 Mhz;
ac signals = 50 m V (p-p)
trr IF = IR = 10 to 100 mA dc R L = 100 ohms ns 4 4
DIM D F G G1 S
MILLIMETERS INCHES MIN MAX MIN MAX 1.60 1.70 0.063 0.067 0.41 0.55 0.016 0.022 3.30 3.70 .130 .146 2.54 REF. .100 REF. 0.03 MIN. .001 MIN.
µA
FIGURE 1
V dc CDLL3600 CDLL4150,-1 75 75
pF 2.5 2.5
DESIGN DATA
CASE: DO-213AA, Hermetically sealed glass case. (MELF, SOD-80; LL34)
FORWARD VOLTAGE LIMITS – ALL TYPES
V F1 Limits I F = 1 mA dc V F2 I F = 10 mA dc V F3 I F = 50 mA dc (Pulsed) V dc 0.780 0.860 V F4 I F = 100 mA dc (Pulsed) V dc 0.820 0.920 V F5
LEAD FINISH: Tin / Lead
I F = 200 mA dc (Pulsed) V dc 0.870 1.000
V dc minimum maximum 0.540 0.620
V dc 0.680 0.740
THERMAL RESISTANCE (ROJEC): 100 °C/W maximum AT L = 0 THERMAL IMPEDANCE: (ZOJX): 70 °C/W maximum POLARITY: Cathode end is banded. MOUNTING SURFACE SELECTION: The Axial Coefficient of Expansion (COE) Of this Device is Approximately +6PPM/°C. The COE of the Mounting Surface System Should Be Selected To Provide A Suitable Match With This Device.
6 LAKE STREET, LAWRENCE, MASSACHUSETTS 01841 PHONE (978) 620-2600 FAX (781) 689-0803 WEBSITE: http://www.microsemi.com
115
IN4150UR-1, IN3600UR-1, CDLL4150 and CDLL3600
1000
100 IF - Forward Current - (mA)
10
15
10 0º C
0º
C
1
25º
C
0.1 .3 .4 .5 .6 .7 .8 .9 1.0 VF - Forward Voltage (V) FIGURE 2 Typical Forward Current vs Forward Voltage 1.1 1.2 1.3
1000
100
150ºC
10
IR - Reverse Current - (µA)
100ºC
1
0.1
25ºC
.01
-65ºC
-65ºC
NOTE : .001 20 40 60 80 100 120 140 Percent of Reverse Working Voltage (%) FIGURE 3 Typical Reverse Current vs Reverse Voltage
All temperatures shown on graphs are junction temperatures
116
.