DatasheetsPDF.com

TEW5316

Filtran

CEPT Output Transformer

www.DataSheet4U.com CEPT TEW5316 is designed and approved to be used as a transmit transformer in CEPT applications wit...


Filtran

TEW5316

File Download Download TEW5316 Datasheet


Description
www.DataSheet4U.com CEPT TEW5316 is designed and approved to be used as a transmit transformer in CEPT applications with the following devices: – STC TEL5219L Output Transformer Typical applications are: Primary rate ISDN network nodes. PBX or computer to T1/CEPT Digital Trunks. TDM Multiplexers. TEW5316 Complies with CCITT G.703 and I.431 with regards to Longitudinal Balance, Pulse Mask and Impedance. MECHANICAL 3 Top view 5 6 4 Line Device 5 6 4 2 1 2 8.0 max. 3 1 White dot at pin 1 7.0 All dimensions are in mm. 5.5 max Recommended foot print TEW5316.chp ELECTRICAL SPECIFICATION TEW5316 94/11/07 Line Impedance Turns ratio Inductance (mH) Longitud. Bal. Pulse Mask Dielectric Strength (Vrms) (4-5) (2-1) : (1-3) : (4-5) (2-1)&(1-3) 120 Ω 1 : 1 : 0.71 > 0.5 I.431 G.703 1500 ISSUE: A Filtran Limited 229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3, Tel : (613) 226 -1626 Fax : (613) 226 -7124 2-36 ...




Similar Datasheet