CEPT/T1 In/Output Transformer
www.DataSheet4U.com
CEPT/T1
TEW5315 is designed to be used either as a transmit or a receive transformer in the ISDN pr...
Description
www.DataSheet4U.com
CEPT/T1
TEW5315 is designed to be used either as a transmit or a receive transformer in the ISDN primary access network, interfacing the SIEMENS PEB2235 to a 75, 100 or 120 ohm line. When in transmit mode, connect the two primary windings in parallel, pin 3 to 4 and pin 6 to 5.
In/Output Transformer
When in receive mode, connect the two primary windings in series, pin 6 to pin 4, thus forming a center tap at pin 6/4. Typical applications are: Primart rate ISDN network nodes. PBX or computer to T1/CEPT Digital trunk TDM Multiplexers
TEW5315
MECHANICAL
1 Line
3 6 Device 4
Com 1 Line 75 Ω 7 120 Ω 8 TEW5315 -4
3 6 Device 4 5
8 TEW5315 -1, -2 & -3
5
Top view
9.6
12.2 2.54 (6 places)
All dimensions are in mm
0.6 9.1 1.9
Recommended foot print 5.2 max 1.27
2.54 7.62
12.7
TEW5315.chp
ELECTRICAL SPECIFICATION Line Impedance Inductance (mH) Turns Ratio Pulse Mask Longitud. Bal. Return Loss Dielectric Strength (Vrms) (1-8) (1-7) (1-8) (3-6):(4-5):(1-8) (3-6):(4-5):(1-7)
TEW5315 -1 100 Ω > 3.4 1 : 1 : 2.67 T1 T1.408 T1.408 1500
-2 75 Ω > 0.75 1 : 1 : 1.57 CEPT I.431 G.703 1500
-3 120 Ω > 1.2 1 :1 : 2 CEPT I.431 G.703 1500
-4 120 Ω 75 Ω > 1.2 1:1:2 1 : 1 : 1.57 CEPT I.431 G.703 1500
ISSUE: B
96/08/08
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3, Tel : (613) 226-1626 Fax : (613) 226-7124