Switchable Current Regulators
IXCP 10M45S IXCY 10M45S
VAK = 450 V IA(P) = 2 - 100 mA RDYN = 9 - 9...
www.DataSheet4U.com
Switchable Current
Regulators
IXCP 10M45S IXCY 10M45S
VAK = 450 V IA(P) = 2 - 100 mA RDYN = 9 - 900 kΩ
Symbol VAKR VAGR VGK ID PD TJ Tstg TL MD
Test Condition TJ = 25°C to 150°C TJ = 25°C to 150°C 10M35S 10M35S
Maximum Ratings 450 450 ± 20 V V V A W °C °C °C Nm/lb.in. Nm/lb.in. G K Pin connections 1 = G, Control terminal; 2 and 4 = A (+) Positive terminal 3 = K (-), Negative terminal TO-252 AA (IXCY) A G A K TO-220 AB (IXCP) A
TC = 25°C TC = 25°C
-0.3 40 -55 ... +150 -55 ... +150 260 0.45/4 0.55/5
Temperature for Soldering (max. 10 s) Mounting torque with screw M3 (TO-220) with screw M3.5 (TO-220)
Features Symbol Test Condition Characteristic Values (TJ = 25°C unless otherwise specified) min. typ. max. 10M35S 450 7 -5 25 160 10 15 V mA V µA kΩ 3.1 K/W 80 K/W 100 K/W
z Minimum of 350/450 V
breakdown
z Resistor programmable current
VAKR IA(P) VG(off) IAV ∆VAK/∆ IA(p RthJC RthJA
RK = 300 Ω, (Fig. 4)
source
z 40 W continuous dissipation z International standard packages
VD = 10 V; RK = 300 Ω; (Fig. 5) ID = 100 µA; VD = 400 V 10M45S Fig. 4 VD= 400 V; VGK = -10 V Fig. 4 10M45S
JEDEC TO-220 and TO-252
z On/Off switchable current source
Applications Start-up circuits for SMPS Highly stable voltage sources Surge limiters and voltage protection Instantaneously reacting resetable fuses z Soft start-up circuits
z z z z
Dynamic resistance; VD= 10 V RK = 300 Ω; (Fig. 4)
Thermal Resistance junction-to-case Thermal Resistance junction-to-ambient TO-220 ...