DatasheetsPDF.com

MB86603 Dataheets PDF



Part Number MB86603
Manufacturers ETC
Logo ETC
Description (MB86603PFV) CMOS SCSI2 Protocol Controller
Datasheet MB86603 DatasheetMB86603 Datasheet (PDF)

∗∗∗∗∗ C-MOS SCSI2 PROTOCOL-CONTROLLER -TOP VIEW MB86603PFV(1/4) IL16 132 130 NC NC 120 GND NC NC NC NC GND VDD (+5V) 110 NC NC NC GND NC 100 NC GND NC GND (OPEN) (OPEN) 90 89 VDD (+5V) NC GND NC NC NC 20 VDD (+5V) GND NC NC NC NC GND 140 VDD (+5V) 133 GND NC 88 GND VDD (+5V) NC VDD (+5V) GND VDD (+5V) 80 150 GND VDD (+5V) NC 160 NC GND NC 170 VDD (+5V) NC 1 NC 176 w w w t a .D 10 S a GND NC GND NC NC NC 30 GND NC NC GND NC e h U 4 t e .c m o 70 60 50 GND VDD (+5V) .

  MB86603   MB86603



Document
∗∗∗∗∗ C-MOS SCSI2 PROTOCOL-CONTROLLER -TOP VIEW MB86603PFV(1/4) IL16 132 130 NC NC 120 GND NC NC NC NC GND VDD (+5V) 110 NC NC NC GND NC 100 NC GND NC GND (OPEN) (OPEN) 90 89 VDD (+5V) NC GND NC NC NC 20 VDD (+5V) GND NC NC NC NC GND 140 VDD (+5V) 133 GND NC 88 GND VDD (+5V) NC VDD (+5V) GND VDD (+5V) 80 150 GND VDD (+5V) NC 160 NC GND NC 170 VDD (+5V) NC 1 NC 176 w w w t a .D 10 S a GND NC GND NC NC NC 30 GND NC NC GND NC e h U 4 t e .c m o 70 60 50 GND VDD (+5V) GND NC GND 45 40 44 w w w .D a t a e h S 4 t e U m o .c MB86603PFV(2/4) VDD =(+5V) PIN No. I/O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 O O O I/O SIGNAL NC DBOE6 DBOE5 Vss DBOE4 NC LDBP Vss NC DB7 DB6 NC DB5 Vss NC DB4 NC DB3 NC DB2 VDD Vss NC NC DB1 DB0 NC UDBP NC Vss NC DB15 DB14 NC DB13 Vss NC DB12 DBOE3 DBOE2 DBOE1 DBOE0 UDBOEP VDD PIN No. I/O 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 O O O I I I SIGNAL Vss DBOE15 DBOE14 DBOE13 PIN No. I/O SIGNAL OPEN OPEN Vss DBOE8 INIT TARG NC TEST2 Vss NC DB11 DB10 NC DB9 Vss NC DB8 NC I/O NC REQ VDD Vss NC C/D NC SEL NC MSG NC Vss NC RST NC ACK BSY Vss NC ATN NC SELOE RSTOE BSYOE VDD PIN No. I/O I I I I I I I I/O I/O I/O I/O I/O I/O I/O I/O I/O SIGNAL Vss A0 A1 A2 A3 A4 CS0 CS1 LDP Vss D0 VDD D1 D2 D3 D4 D5 D6 D7 Vss VDD NC D8 D9 D10 D11 D12 NC D13 D14 D15 UDP Vss NC BHE WR (LDS) VDD RD (R/W) INT (INT) MODE RESET LDBOEP DBOE7 NC I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O O O O O O 89 90 91 92 93 S/DSEL IORD (DMR/W) 94 IOWR (DMLDS) 95 NC 96 I DMA0 97 I/O LDMDP 98 Vss 99 I/O DMD0 100 I/O DMD1 101 VDD 102 I/O DMD2 103 I/O DMD3 104 I/O DMD4 105 I/O DMD5 106 I/O DMD6 107 I/O DMD7 108 Vss 109 I/O 110 DMD8 I/O 111 DMD9 I/O 112 DMD10 I/O 113 DMD11 I/O 114 DMD12 115 VDD I/O 116 DMD13 I/O 117 DMD14 I/O 118 DMD15 119 Vss I/O 120 UDMDP 121 VDD I 122 CLK I DMBHE (DMUDS) 123 124 NC 125 I DACK 126 O DREQ 127 I TP 128 O DBOE12 129 O DBOE11 130 O DBOE10 131 O DBOE9 132 NC O O O I I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O I/O O O O 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 I/O I/O I/O I/O I/O I/O I/O I/O I/O I I I O I I/O O O MB86603PFV(3/4) INPUT A0-A4 BHE (UDS) CLK CS0,CS1 DACK DMA0 DMBHE (DMUDS) IORD (DMR/W) IOWR (DMLDS) MODE RD (R/W) S/DSEL TP TEST2 WR (LDS) ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ADDRESS 0-4 BUS HIGH ENABLE (UPPER DATA STROBE) CLOCK CHIP SELECT 0,1 DMA ACKNOWLEDGE DMA ADDRESS 0 DMA BUS HIGH ENABLE (DMA UPPER DATA STROBE) I/O READ (DMA READ/WRITE) I/O WRITE (DMA LOWER DATA STROBE) MODE READ (READ/WRITE) SINGLE-END DIFFERENTIAL SELECT TRANSFER PERMISSION TEST WRITE (LOWER DATA STROBE) BUSY OUTPUT ENABLE DATA BUS0-7 ENABLE DATA BUS8-15 ENABLE DMA REQUEST INITIATOR INTERRUPT REQUEST LOWER DATA BUS OUTPUT ENABLE PARITY RESET OUTPUT ENABLE SELECT OUTPUT ENABLE TARGET UPPER DATA BUS OUTPUT ENABLE PARITY ACKNOWLEDGE ATTENTION BUSY CONTROL/DATA DATA 0-7 DATA 8-15 DATA BUS0-7 DATA BUS 8-15 DMA DATA 0-7 DMA DATA 8-15 INPUT/OUTPUT LOWER DATA PARITY LOWER DATA BUS PARITY LOWER DMA DATA PARITY MESSAGE REQUEST RESET RESET SELECT UPPER DATA PARITY UPPER DATA BUS PARITY OUTPUT BSYOE DBOE0-7 DBOE8-15 DREQ INIT INT (INT) LDBOEP RSTOE SELOE TARG UDBOEP INPUT/OUTPUT ACK ATN BSY C/D D0-D7 D8-15 DB0-7 DB8-15 DMD0-7 DMD8-15 I/O LDP LDBP LDMDP MSG REQ RESET RST SEL UDP UDBP UDMDP ; UPPER DMA DATA PARITY MB86603PFV(4/4) MSG C/D I/O ATN SEL RST REQ ACK BSY 117 113 107 127 115 121 109 123 124 134-138 A4-0 VARIOUS 1 INTERNAL 5 PROCESSOR REGISTER MPU INTERFACE 163-161,159-155,164 151-145,143,141 D15-8,UDP D7-0,LDP 171 168 170 139 140 167 172 SCSI INTERFACE 131 BSYOE 129 SELOE 93 INIT 94 TARG 130 RSTOE 32,33,35,38,99, 100,102,105,28 DB15-8 UDBP 10,11,13,16,18, 20,25,26,7 DB7-0 LDBP 46-48, 84-87,92,43 DBOE15-8 UDBOEP 175,2,3,5, 39-42,174 DBOE7-0 LDBOEP S/DSEL 49 2 TIMER 6 (32BYTE) INT (INT) WR (LDS) RD (R/W) CS0 CS1 BHE MODE RECIEVE MSG,CMD, STATUS BUFFER 3 PHASE CONTROLLER 7 (32BYTE) 4 TRANSFER CONTROLLER SEND MSG,CMD, STATUS BUFFER 74-72,70-66, 64-59,57,56,54 8 (512BYTE) DMA INTERFACE DMD15-8,UDMDP DMD7-0,LDMDP 82 81 79 53 51 50 83 USER PROGRAM MEMORY DREQ DACK DMBHE (DMUDS) DMA0 IOWR (DMLDS) IORD (DMR/W) TP 9 DATA REGISTER (64BYTE) .


MB86603 MB86603 KX-TCD450NZ


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)