DatasheetsPDF.com

CSNF161 Dataheets PDF



Part Number CSNF161
Manufacturers Soild State Sensors
Logo Soild State Sensors
Description (CSN Series) Closed Loop Current Sensors
Datasheet CSNF161 DatasheetCSNF161 Datasheet (PDF)

Solid State Sensors Closed Loop Current Sensors CSN Series CATALOG NUMBER SYSTEM PLEASE NOTE: This matrix is intended only to aid you in identifying sensor catalog listings. It is not all-inclusive, and must not be used to form new listings. Example: CSNA111 CSN Closed Loop Current Sensor Current Range (Peak/RMS nom.) A ±70 A/50 A rms nom. B ±100 A/50 A rms nom. C ±90 A/50 A rms nom. D ±22 A/15 A rms nom. E ±36 A/25 A rms nom. F ±150 A/100 A rms nom. J ±600 A/300 A rms nom. K ±1200 A/500 A rms.

  CSNF161   CSNF161


Document
Solid State Sensors Closed Loop Current Sensors CSN Series CATALOG NUMBER SYSTEM PLEASE NOTE: This matrix is intended only to aid you in identifying sensor catalog listings. It is not all-inclusive, and must not be used to form new listings. Example: CSNA111 CSN Closed Loop Current Sensor Current Range (Peak/RMS nom.) A ±70 A/50 A rms nom. B ±100 A/50 A rms nom. C ±90 A/50 A rms nom. D ±22 A/15 A rms nom. E ±36 A/25 A rms nom. F ±150 A/100 A rms nom. J ±600 A/300 A rms nom. K ±1200 A/500 A rms nom. L ±600 A/300 A rms nom. M ±1200 A/500 A rms nom. P ±90 A/50 A rms nom. R ±200 A/125 A rms nom. T ±150 A/50 A rms nom. FEATURES ɀ Current sensing up to 1200 amps ɀ Measures AC, DC and impulse currents ɀ Lowest cost/performance ratio ɀ Rapid response, no overshoot ɀ High overload capacity ɀ High level of electrical isolation between primary and secondary circuits ɀ Small size and weight CLOSED LOOP SENSORS Closed loop current sensors measure AC, DC and impulse currents over 0-25, 0-50, 0-100, 0-600 and 0-1200 Amp ranges. The CSN Series is based on the principles of the Hall effect and the null balance or zero magnetic flux method (feedback system). The magnetic flux in the sensor core is constantly controlled at zero. The amount of current required to balance zero flux is the measure of the primary current flowing through the conductor, multiplied by the ratio of the primary to secondary windings. This closed loop current is the output from the device and presents an image of the primary current reduced by the number of secondary turns at any time. This current can be expressed as a voltage by passing it through a resistor. w w .D w t a S a e h t e U 4 .c m o Supply Voltage 1 ±15 V 2 ±13 V 3 ±5 V 4 ±12 V to 18 V 5 ±15 V to 24 V 6 ±12 V to 15 V Coil Characteristics 1 1:1000 turns/90 ȉ @ 70°C 2 1:2000 turns/160 ȉ @ 70°C 3 1:2000 turns/130 ȉ @ 70°C 4 1:1000 turns/50 ȉ @ 70°C 5 1:1000 turns/110 ȉ @ 70°C 6 1:1000 turns/30 ȉ @ 70°C 7 1:2000 turns/80 ȉ @ 70°C 8 1:2000 turns/25 ȉ @ 70°C 9 1:5000 turns/50 ȉ @ 85°C Housing Material 1 Polycarbonate/ABS blend PDFINFO p a g e - 0 6 0 w 60 w w .D a S a t e e h U 4 t m o .c Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada Solid State Sensors Closed Loop Current Sensors CSNA, CSNB, CSNE SERIES ORDER GUIDE Catalog Listing CSNA111 CSNB121 CSNB131 CSNE151 CSNE381* CSNH151* Current Range Amps ±70 ±100 ±100 ±5-36 ±5-36 ±4-43 Supply Voltage VDC ±5% ±15 ±15 ±15 ±15 ±5V ±15V Coil Characteristics Turns Resistance 1000 2000 2000 1000 1000 1000 90ȉ @ 70°C 160ȉ @ 70°C 130ȉ @ 70°C 110ȉ @ 70°C 66ȉ @ 70°C 110ȉ @ 70°C Meas. Currents Nom. 50 mA for 50 A 25 mA for 50 A 25 mA for 50 A 25 mA for 25 A 25 mA for 25 A 25 mA for 25 A Meas. Resist (@ Inom) 40 to 130ȉ 40 to 270ȉ 40 to 300ȉ 100 to 320ȉ 0 to 84ȉ 100 to 320ȉ CSN Series NOTE: Extended temperature range and potting also available. * Contact the 800 number for more information. SPECIFICATIONS Catalog Listing Offset Current @ 25°C, mA max. Temperature Drift, 0 to 70°C, mA Linearity Supply Voltage Galvanic Isolation @ 50 Hz/1 min. Accuracy Response Time Bandwidth Temperature Primary Circuit Connection Secondary Circuit Connection Current Drain ‘‘In-Out’’ Sense Signal Mounting CSNA111 ±0.20 ±0.35 typ. ±0.60 max. 0.1% ±15V 2.5 kV rms ±0.5% of IN (nominal Current) at 25°C <1 Ȗs DC to 150 kHz Operating: 0 to 70°C (32 to 150°F) Thru-hole 3 Pins Thru-hole 3 Pins Storage: −25 to 85°C (−13 to 185°F) Thru-hole 3 Pins Invasive on 10 pins 3 Pins CSNB121 ±0.10 ±0.20 typ. ±0.30 max. 0.1% ±15V CSNB131 ±0.10 ±0.20 typ. ±0.30 max. 0.1% ±15V CSNE151 ±0.10 ±0.17 typ. ±0.60 max. 0.2% ±15V 5 kV rms 10 mA (no load current) + output current (secondary current) To obtain positive measuring current on O/P terminal, current must flow in direction of arrow PCB, 3 pins, hole size 0.95 mm PCB, 13 pins PRIMARY PIN CONNECTIONS FOR CSNE151 Primary Current Primary Turns 1 Nom. IDN (A) 24 Max. ID (A) 36 Output Current (mA) 25 Primary Resistance (mȉ) 0.3 Primary Pin Connections Current 2 12 18 24 1.1 3 8 12 24 2.5 4 6 9 24 4.4 5 5 7 25 6.3 WIRING DIAGRAMS CSNA111/CSNB121/CSNB131 CSNE151 PDFINFO p a g e - 0 6 1 Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada 61 Solid State Sensors Closed Loop Current Sensors MOUNTING DIMENSIONS (for reference only) CSNA111, CSNB121, CSNB131 CSN Series CSNE151/CSNE381 CSNH151 PDFINFO p a g e - 0 6 2 62 Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada Solid State Sensors Closed Loop Current Sensors CSNJ, CSNK SERIES ORDER GUIDE Current Range Amps ±600 ±600 ±600 ±600 ±1200 ±1200 ±1200 ±1200 Supply Voltage VDC ± 5% ±12 to 18 ±12 to 18 ±12 to 18 ±12 to 18 ±15 to 24 ±15 to 24 ±15 to 24 ±15 to 24 Coil Characteristics Turns 2000 2000 2000 2000 5000 5000 5000 5000 Resistance.


CSNJ481 CSNF161 CSNA111


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)