POLARISED / MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation
SF
POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation
π
53.3±0.3 2.098±.012 25.0 .984...
Description
SF
POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation
π
53.3±0.3 2.098±.012 25.0 .984 16.5±0.3 .650±.012
(SF3 pending) (SF3 pending)
(SF3 pending)
SF-RELAYS
enables to plan a circuit to detect welding or go back to the beginning condition. Separated chamber structure (2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A 4 Form B) N.O. and N.C. side contacts are put in each own space surrounded with a card and a body-separater. That prevents short circuit between contacts, which is caused by their springs welding or damaged. UL/CSA, TÜV, SEV approved (UL/CSA, SEV of SF3 pending)
FEATURES
Forced operation contacts (2 Form A 2 Form B, 3 Form A 1 Form B) N.O. and N.C. side contacts are connected through a card so that one interacts with the other in movement. In case of a contact welding, the other keeps a min. 0.5mm .020inch contact gap. Independent operation contacts (4 Form A 4 Form B) Each pair of contacts is free from the main armature and is independent from each other. So if a N.O. pair of contacts are welded, the other 3 N.O. contacts are not effected (operate properly) That
53.3±0.3 2.098±.012
25.0 .984 16.5±0.3 .650±.012
53.3±0.3 2.098±.012
33±0.3 1.299±.012 16.5±0.3 .650±.012
mm inch
SPECIFICATIONS
Contact
Type Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating Max. switching power (resistive) Max. switching voltage Max. carrying current Mechanical (...