Two-Way In-Phase Power Divider 0.4 - 400 MHz
PD10-0041-S
Two-Way In-Phase Power Divider 0.4 - 400 MHz
Features
• • • • • Space Qualified version of DS-113 Designed...
Description
PD10-0041-S
Two-Way In-Phase Power Divider 0.4 - 400 MHz
Features
Space Qualified version of DS-113 Designed to meet the Stringent Reliability Standards of Space Hardware 50 Ohms Nominal Impedance Three Decade Bandwidth Low Loss: -0.25 Typ.
FP-2
PIN 0.015 DIA ±0.005 (0.38 ±0.13) 8 PLACES 1 2 3 4 0.385 ±0.020 (9.8 ±0.5) 5 6 7 8 0.312 MIN TYP (7.9 MIN)
Description
M/A-COM’s PD10-0041-S is a Two-Way In-Phase Power Divider designed to operate between 400 KHz and 400 MHz
0.080 (2.0) 0.100 (2.5)
Absolute Maximum Ratings1
Parameter Max. Input Power Operating Temperature Storage Temperature Absolute Maximum 1 Watt Max. -30°C to +85°C -65°C to +125°C
0.250 (6.3) 0.350 (8.9) 0.051 (12.9 ±0.5)) 0.150 MAX (3.8 MAX) 0.060 (1.5)
1. Operation of this device above any one of these parameters may cause permanent damage. Dimensions in ( ) are in mm. Unless Otherwise Noted: .xxx = ±0.010 (.xx = ±0.25) .xx = ±0.02 (.x = ±0.5) WEIGHT (APPROX.): 0.09 OUNCES 2.5 GRAMS
Electrical Specifications, TA = +25°C
Parameter Insertion Loss Isolation Amplitude Balance Phase Balance VSWR Frequency 0.4-400 MHz 0.4-400 MHz 0.4-400 MHz 0.4-400 MHz 0.4-400 MHz
Units dB dB dB -
Min. 25 -
Max. 0.75 0.15 1° 1.5
1. All specifications apply with a 50-Ohm source and load impedance.
Specifications subject to change without notice. North America: Tel. (800) 366-2266, Fax (800) 618-8883 Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298 Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020 Visit...