DUAL BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP3070H3SL THRU TISP3095H3SL, TISP3125H3SL THRU TISP3210H3SL TISP3250H3SL THRU TISP3350H3SL DUAL BIDIRECTIONAL THYRIST...
Description
TISP3070H3SL THRU TISP3095H3SL, TISP3125H3SL THRU TISP3210H3SL TISP3250H3SL THRU TISP3350H3SL DUAL BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
Copyright © 1999, Power Innovations Limited, UK JANUARY 1999 - REVISED MAY 1999
TELECOMMUNICATION SYSTEM 2x100 A 10/1000 OVERVOLTAGE PROTECTORS
q
Ion-Implanted Breakdown Region - Precise DC and Dynamic Voltages
DEVICE ‘3070 ‘3080 ‘3095 ‘3125 ‘3135 ‘3145 ‘3180 ‘3210 ‘3250 ‘3290 ‘3350 VDRM V 58 65 75 100 110 120 145 160 190 220 275 V(BO) V 70 80 95 125 135 145 180 210 250 290 350
SL PACKAGE (TOP VIEW)
T G R
1 2 3 MDXXAG
device symbol
T R
q
Rated for International Surge Wave Shapes - Guaranteed -40 °C to +85 °C Performance
WAVE SHAPE 2/10 µs 8/20 µs 10/160 µs 10/700 µs 10/560 µs 10/1000 µs STANDARD GR-1089-CORE IEC 61000-4-5 FCC Part 68 FCC Part 68 ITU-T K20/21 FCC Part 68 GR-1089-CORE ITSP A 500 300 250 200 160 100
SD3XAA
G Terminals T, R and G correspond to the alternative line designators of A, B and C
q
3-Pin Through-Hole Packaging - Compatible with TO-220AB pin-out - Low Height. . . . . . . . . . . . . . . . . . . . .8.3 mm Low Differential Capacitance - Value at -2 V/-50 V Bias. . . . . . . .67 pF max.
q
description
The TISP3xxxH3SL limits overvoltages between the telephone line Ring and Tip conductors and Ground. Overvoltages are normally caused by a.c. power system or lightning flash disturbances which are induced or conducted on to the telephone line. The protector consists of two symmetrical voltage-triggered bi...