Document
TLU.240.
Vishay Telefunken
Universal LED, ø 1.8 mm Tinted Diffused Miniplast Package
Color Red Orange red Yellow Green Type TLUR240. TLUO240. TLUY240. TLUG240. Technology GaAsP on GaAs GaAsP on GaP GaAsP on GaP GaP on GaP Angle of Half Intensity ±ö 20° 20° 20° 20°
Features
D D D D
Four colors For DC and pulse operation Luminous intensity categorized End-to-end stackable in centre-to-centre spacing of 0.1” (2.54 mm)
94 8639
Applications
General indicating and lighting purposes
Absolute Maximum Ratings
Tamb = 25_C, unless otherwise specified TLUR240. ,TLUO240. ,TLUY240. ,TLUG240. , Parameter Reverse voltage DC forward current Surge forward current Power dissipation Junction temperature Storage temperature range Soldering temperature Soldering temperature Thermal resistance junction/ambient tp ≤ 10 ms Tamb ≤ 55°C Test Conditions Symbol VR IF IF IF IF IFSM PV Tj Tstg Tsd Tsd RthJA Value 6 50 30 30 30 1 100 100 –55 to +100 260 260 450 Unit V mA mA mA mA A mW °C °C °C °C K/W
t ≤ 3 s, 2 mm from body t ≤ 5 s, 4 mm from body
Document Number 83053 Rev. A1, 04-Feb-99
www.vishay.de • FaxBack +1-408-970-5600 1 (8)
TLU.240.
Vishay Telefunken Optical and Electrical Characteristics
Tamb = 25_C, unless otherwise specified Red (TLUR240. ) Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance Orange red (TLUO240. ) Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance Yellow Test Conditions IF = 10 mA, IVmin/IVmax ≥ 0.5 IF = 10 mA IF = 10 mA IF = 10 mA IF = 20 mA IR = 10 mA VR = 0, f = 1 MHz Type Symbol TLUO2400 IV TLUO2401 IV ld lp ϕ VF VR Cj Min 1.6 4 612 Typ 2 5 630 ±20 2 15 50 Max 20 625 Unit mcd mcd nm nm deg V V pF Test Conditions IF = 10 mA, IVmin/IVmax ≥ 0.5 IF = 10 mA IF = 10 mA IF = 10 mA IF = 20 mA IR = 10 mA VR = 0, f = 1 MHz Type Symbol TLUR2400 IV TLUR2401 IV ld lp ϕ VF VR Cj Min 0.4 1 Typ 0.8 1.5 645 660 ±20 1.6 15 50 Max 5 Unit mcd mcd nm nm deg V V pF
2
6
3
6
(TLUY240. )
Test Conditions IF = 10 mA, IVmin/IVmax ≥ 0.5 IF = 10 mA IF = 10 mA IF = 10 mA IF = 20 mA IR = 10 mA VR = 0, f = 1 MHz Type Symbol TLUY2400 IV TLUY2401 IV ld lp ϕ VF VR Cj Min 1 2.5 581 Typ 4 8 585 ±20 2.4 15 50 Max 12.5 594 Unit mcd mcd nm nm deg V V pF
Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance Green (TLUG240. ) Parameter Luminous intensity y Dominant wavelength Peak wavelength Angle of half intensity Forward voltage Reverse voltage Junction capacitance
3
6
Test Conditions IF = 10 mA, IVmin/IVmax ≥ 0.5 IF = 10 mA IF = 10 mA IF = 10 mA IF = 20 mA IR = 10 mA VR = 0, f = 1 MHz
Type Symbol TLUG2400 IV TLUG2401 IV ld lp ϕ VF VR Cj
Min 1.6 4 562
Typ 5 12 565 ±20 2.4 15 50
Max 20 575
3
6
Unit mcd mcd nm nm deg V V pF
www.vishay.de • FaxBack +1-408-970-5600 2 (8)
Document Number 83053 Rev. A1, 04-Feb-99
TLU.240.
Vishay Telefunken Typical Characteristics (Tamb = 25_C, unless otherwise specified)
125 PV – Power Dissipation ( mW ) 10000 IF – Forward Current ( mA )
100
1000
tp/T=0.01
0.02 0.05
75
50 25 0 0 20 40 60 80 100
0.1 100 0.2 0.5 1 10 Green, Yellow Orange-Red 1 0.01 0.1 1 Tamb
v55°C
10 100
95 9983
Tamb – Ambient Temperature ( °C )
95 10093
tp – Pulse Length ( ms ) 0° 10 ° 20 °
Figure 1 Power Dissipation vs. Ambient Temperature
60 Red IF – Forward Current ( mA ) 50 40 30 20 10 0 0
95 10091
Figure 4 Forward Current vs. Pulse Length
30°
Iv rel – Relative Luminous Intensity
40° 1.0 0.9 0.8 0.7 50° 60° 70° 80° 0.6 0.4 0.2 0 0.2 0.4 0.6
Green, Yellow Orange-Red
20
40
60
80
100
95 10094
Tamb – Ambient Temperature ( °C )
Figure 2 Forward Current vs. Ambient Temperature
10000 IF – Forward Current ( mA ) IF – Forward Current ( mA ) 0.02 1000 0.05 0.1 0.2 100 0.5 1 10 Tamb 1 0.01
95 10092
Figure 5 Rel. Luminous Intensity vs. Angular Displacement
1000
Red tp/T=0.01
Red 100
10
1 tp/T=0.001 tp=10ms 1 1.5 2 2.5 3
v55°C
10 100
0.1
95 10073
0.1
1
tp – Pulse Length ( ms )
VF – Forward Voltage ( V )
Figure 3 Forward Current vs. Pulse Length
Figure 6 Forward Current vs. Forward Voltage
Document Number 83053 Rev. A1, 04-Feb-99
www.vishay.de • FaxBack +1-408-970-5600 3 (8)
TLU.240.
Vishay Telefunken
1.6 Iv rel – Relative Luminous Intensity Iv rel – Relative Luminous Intensity Red 1.2 1.2 Red 1.0 0.8 0.6 0.4 0.2 0 620
95 10077
0.8
0.4
0 0
95 10074
IF=10mA 20 40 60 80 100 Tamb – Ambient Temperature ( °C )
640
660
680
700
720
l – Wavelength ( nm )
Figure 7 Rel. Luminous Intensity vs. Ambient Temperature
2.4 Iv rel – Relative Luminous Intensity Red
Figure 10 Relative Luminous Intensity vs. Wavelength
1000 Orange-Red IF – Forward Current ( mA ) 100
2.0 1.6 1.2 0.8 0.4 IFAV=10mA, const. 0 10 20 0.5 50 0.2 100 0.1 200 0.05 500 0.02 IF(mA) tp/T
10
1 tp/T=0.001 tp=10ms 0 2 4 6 8 10
0.1 1
95 10086
95 10075
VF – Forw.