Document
Open Frame Power Supplies
TOL Series
Features
Small and compact PCB Construction Optional with Chassis and Cover Universal Input 85 –264 VAC, Output Voltage adjustable Compliance to EN 61000-3-2 (PFC) EMI meets EN55022, Class B and FCC, Level B Short Circuit and Overvoltage Protection International Safety Standards Industrial Quality Standard 2 Year Product Warranty The TOL Series switching power supplies are the best choice for many space critical applications. They feature ultra-compact dimensions and a low profile. As an accessory a chassis and cover kit for self-installation is available for all models. To make installation even more simple, prewired mating output/input connectors with flying leads are also offered as an accessory. Compliance with international safety standards (CE /UL) and EMC specifications qualify this product for worldwide use. A very high reliability is guaranteed by the use of industrial quality grade components and excellent thermal management..
10 - 300 Watt
Models
Order Code TOL 10-05 TOL 10-12 TOL 10-24 TOL 15-05 TOL 15-12 TOL 15-24 TOL 30-05 TOL 30-12 TOL 30-24 TOL 50-05 TOL 50-12 TOL 50-24F TOL 75-05 TOL 75-12 TOL 75-24F TOL 100-05 TOL 100-12 TOL 100-24F TOL 100-48 TOL 150-05 TOL 150-12 TOL 150-24F TOL 150-48 TOL 300-24 TOL 300-48 Output Power 10 Watt Output Voltage 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 48 VDC 5 VDC 12 VDC 24 VDC 48 VDC 24 VDC 48 VDC Output Current max. 2 0.9 0.5 3 1.3 0.6 6 2.5 1.3 10 4.3 2.2 15 6.3 3.2 20 8.5 4.5 2.1 30 13 6.5 3.3 14 6.3 A A A A A A A A A A A A (peak 3.0 A)* A A A (peak 4.5 A)* A A A (peak 6.3 A)* A A A A (peak 9.1 A)* A A A
15 Watt
30 Watt
50 Watt
75 Watt
100 Watt
150 Watt
300 Watt
* Peak current for max. 10sec
http://www.tracopower.com
Page 1
Open Frame Power Supplies
TOL Series 10 – 300 Watt
Input Specifications
Input voltage range Input frequency Inrush current at 25°C (< 2ms) 85 – 264 VAC 47 – 63 Hz 15 A max. (Vin 120 VAC) 30 A max. (Vin 230 VAC)
Output Specifications
Output voltage adjustment range Regulation Ripple and noise (20Mhz Bandwidth) – Input variation – Load variation (10 – 100%) 5VDC output models: 12/24VDC output models: 48VDC output models: ± 10 % 0.5 % max. 0.8 % max. 100 mV pp max. 180 mV pp max. 300 mV pp max. (TOL 300: 600mV pp max) 105% – 140% of Inom. hiccup mode, indefinite (automatic recovery) constant current (automatic recovery) 115 – 135 % Vout nom. – TOL10 – TOL15 – other models 10’000 µF max. (24 Vout model: 2’000 µF) 15’000 µF max. (24 Vout model: 6’000 µF) 18’000 µF max.
Output current limitation (except for F versions) Short circuit protection Overvoltage protection Capacitive load – 10 to 30 Watt models: – 50 to 300 Watt models:
General Specifications
Temperature ranges – Operating (ambient temp.) – Derating above 50°C – Storage (non operating) –10 °C…+60°C (TOL150: –10°C...+50°C) 3 %/°C (TOL150: 1.5 %/°C above 35°C) –20 °C…+ 75 °C 0.02 % / °C 75 % typ. 20 % – 90 % rel. 100 kHz typ. (PWM) 20 ms typ. at full load – Input / output – Input / FG (or case) – Output / FG (or case) 3‘000 VAC for 1min. 2’000 VAC for 1min. 500 VDC for 1min. 100 MOhm 0.6 mA RMS typ. / 230 VAC / 60 Hz – Conducted input RI suppression – Harmonic current emissions – Electrostatic discharge – Surge immunity EN 55022, class B; FCC Part 15, level B IEC / EN 61000-3-2, class A IEC / EN 61000-4-2 8kV / 15kV IEC / EN 61000-4-5 2kV / 4kV
Temperature coefficient Efficiency Humidity (non condensing) Switching frequency Hold-up time Isolation voltage
Isolation resistance Leakage current Electromagnetic compatibility (EMC) Emission Electromagnetic compatibility (EMC) Immunity
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2
Open Frame Power Supplies
TOL Series 10 – 300 Watt
General Specifications
Safety standards Reliability, calculated MTBF (MIL-HDBK-217E) – TOL10 / TOL15: – TOL30: – TOL50 / TOL75: – TOL100 / TOL150: TOL300: Remote ON /OFF (available as option for models TOL30/50/75/100/150/300) Remote sensing (only TOL300 models) Vibration On: Off: EN 60950, UL /cUL 1950 File E188913 > > > > 650’000 500’000 375’000 350’000 h h h h @ @ @ @ 25 °C 25 °C 25 °C 25 °C
> 260’000 h @ 25 °C 5 VDC (input resistance 1 KOhm) 0V or open circuit previred connector included use Molex housing / pin 67260-0400 / 67260 to connect sens line at P54 IEC 60068-2-6, 5-10 Hz with 10mm amplitude 2 gn, 60 sweeps of 10-55 Hz, each axis IEC 60068-2-27, 20 gn each axis
– without sens line: – with sens line:
Shock resistance
Mating Connectors with prewired flying Leads (500mm Length)
OrderCode TOL-C31 Description Input cable for all models TOL 10/15 output cable TOL 30/50 output cable TOL 75 output cable TOL 150 output cable + TOL 150 output cable – TOL 100 output cable Pin no. 1 3 5 1–2 3–4 1–2 3–4 1–3 4–6 1–6 1–7 1–4 5–8 Wire Color black white green black red black r.