SLIM POLARIZED RELAY
TN-RELAYS
• Surge voltage withstand: 1500 V FCC Part 68 • Sealed construction allows automatic cleaning • Self-clinching terminal also available
14 .551
5.6 .220 9.8 .386
FEATURES
• Small size for minimal PC board mounting requirements • Small header area makes higher density mounting possible • High sensitivity: 140 mW nominal operating power (single side stable 3-12 V type)
mm inch
SPECIFICATIONS
Contact
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1A) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Rating Max. switching voltage Max. switching current Min. switching capacity f1 Single side stable Nominal operating power 1 coil latching 2 coil latching Mechanical (at 180 cpm) 1 A 30 V DC resistive load Electrical (at 20 cpm) 0.5 A 125 V AC resistive load 2 Form C 60 mΩ Gold-clad silver 1 A 30 V DC, 0.5 A 125 V AC 30 W, 62.5 VA 110 V DC,125 V AC 1A 10 µA 10 mV DC 140 mW (3 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC) 100 mW (3 to 12 V DC) 150 mW (24 V DC) 200 mW (3 to 12 V DC) 300 mW (24 V DC) 108 2 × 105 105
Characteristics
Initial insulation resistance*1 Between open contacts Initial Between contact and breakdown coil voltage Between contact sets FCC surge voltage between open contacts Temperature rise*2 (at 20°C) Operate time [Set time]*3 (at 20°C) Release time [Reset time]*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7 Vibration resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Ambient temperature Humidity Max. 3 [Max. 3 Max. 3 [Max. 3 Min. 1,000 MΩ (at 500 V DC) 750 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 V Max. 50°C ms (Approx. 2 ms (Approx. 2 ms (Approx. 1 ms (Approx. 2
ms) ms)] ms) ms)]
Expected life (min. operations) Note:
Min. 490 m/s2 {50G} Min. 980 m/s2 {100G} 176.4 m/s2 {18G}, 10 to 55 Hz at double amplitude of 3 mm 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Approx. 1.5 g .053 oz
f1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 1 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. 4 * Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs. *6 Half-wave pulse of sine wave: 6 ms. *7 Detection time: 10 µs. *8 Refer to 4. Conditions for operation, transport and storage mentioned in Cautions for us.