Precision Reference Supplies
VRE100/101/102
Precision Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 88...
Description
VRE100/101/102
Precision Reference Supplies
THALER CORPORATION 2015 N. FORBES BOULEVARD TUCSON, AZ. 85745 (520) 882-4000
FEATURES
VERY HIGH ACCURACY: 10.000 V OUTPUT ±0.5 mV EXTREMELY LOW DRIFT: 0.5 ppm/°C 55°C to +125°C LOW WARM-UP DRIFT: 1.0 ppm Typ. EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ. EXCELLENT LINE REGULATION: 3 ppm/V Typ. HERMETIC 14-PIN CERAMIC DIP MILITARY PROCESSING OPTION PIN & FUNCTION COMPATIBLE WITH AD2700, AD2710 Series
APPLICATIONS
PRECISION A/D and D/A CONVERTERS TRANSDUCER EXCITATION ACCURATE COMPARATOR THRESHOLD REFERENCE HIGH RESOLUTION SERVO SYSTEMS DIGITAL VOLTMETERS HIGH PRECISION TEST and MEASUREMENT INSTRUMENTS
DESCRIPTION
VRE100 Series Precision Voltage References provide ultrastable +10.000V (VRE100), 10.000V (VRE101) and ±10.000V (VRE102) outputs with ±0.5 mV initial accuracy and temperature coefficient as low as 0.5 ppm/°C over the full military temperature range. This improvement in accuracy is made possible by a unique, proprietary multipoint laser compensation technique developed by Thaler Corporation. Significant improvements have been made in other performance parameters as well, including initial accuracy, warm-up drift, line regulation, and long-term stability, making the VRE100 series the most accurate and stable 10V reference available.
SELECTION GUIDE
Type
VRE100C VRE100CA VRE100M VRE100MA VRE101C VRE101CA VRE101M VRE101MA VRE102C VRE102CA VRE102M VRE102MA
Output
+10V +10V +10V +10V -10V -10V -...