Document
MCC
Features
• • • • • Glass Passivated Chip Low Forward Voltage Drop High Current Capability High Surge Current Capability Low Leakage
omponents 21201 Itasca Street Chatsworth !"# $
% !"#
60S05 thru 60S10
6 Amp Axial-Lead Glass Passivated Rectifier 50 - 1000 Volts
DO-201AD
• •
Maximum Ratings
MCC Catalog Number Device Marking
Operating Junction Temperature: -65 °C to +175°C Storage Temperature: -65°C to +175°C Maximum Reccurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage
D
60S05 60S1 60S2 60S4 60S6 60S8 60S10
60S05 60S1 60S2 60S4 60S6 60S8 60S10
35V 70V 140V 280V 420V 560V 700V
50V 100V 200V 400V 600V 800V 1000V
A Cathode Mark B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage Maximum DC Reverse Current At Rated DC Blocking Voltage Typical Junction Capacitance IF(AV) IFSM 6.0A 200A TA = 100°C 8.3ms, half sine
C
VF
1.0V 5 µA 100µA 150pF
IFM = 6.0A; TJ = 25°C* TJ = 25°C TJ = 100°C Measured at 1.0MHz, VR=4.0V
DIMENSIONS INCHES MIN ----.048 1.000 MM MIN ----1.20 25.40
IR
DIM A B C D
MAX .370 .250 .052 ---
MAX 9.50 6.40 1.30 ---
NOTE
CJ
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
www.mccsemi.com
60S05 thru 60S10
Figure 1 Typical Forward Characteristics 200 100 60 40 20 Amps 10 6 4 2 25°C 1 .6 .4 .2 .1 .4 .6 0.8 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 1.0 1.2 1.4 100 60 40 20 10 6 Figure 3 Maximum Non-Repetitive Forward Surge Current 300 2 250 200 150 Amps 100 50 5 0 µ Amps 1 .6 .4 .2 .1 .06 1 2 4 6 8 10 Cycles .02 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles .01 20 40 60 80 100 .04 TJ=25°C TJ=100°C 4 0 Amps 2 4 6
MCC
Figure 2 Forward Derating Curve 5
3
1 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 125 150 175
°C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C Figure 4 Typical Reverse Characteristics
20
40
60
80 Volts
100
120
140
Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com
.