Document
HVR112 - HVR120
PRV : 1200 - 2000 Volts Io : 1.0 Ampere
FEATURES :
* * * * * High current capability High surge current capability High reliability Low reverse current Low forward voltage drop
HIGH VOLTAGE RECTIFIER DIODES
DO - 41
0.107 (2.7) 0.080 (2.0)
1.00 (25.4) MIN.
0.205 (5.2) 0.166 (4.2)
MECHANICAL DATA :
* Case : DO-41 Molded plastic * Epoxy : UL94V-O rate flame retardant * Lead : Axial lead solderable per MIL-STD-202, Method 208 guaranteed * Polarity : Color band denotes cathode end * Mounting position : Any * Weight : 0.339 gram
0.034 (0.86) 0.028 (0.71) 1.00 (25.4) MIN.
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
RATING
Maximum Repetitive Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Current Peak Forward Surge Current 8.3ms Single half sine wave Superimposed on rated load (JEDEC Method) Maximum Peak Forward Voltage at IF = 1.0 Amp. Maximum DC Reverse Current at Rated DC Blocking Voltage Ta = 25°C Ta = 100°C Ta = 75°C
SYMBOL HVR112 HVR114 HVR116 HVR118 HVR120
VRRM VRMS VDC IF(AV) 1200 840 1200 1400 980 1400 1600 1120 1600 1.0 1800 1260 1800 2000 1400 2000
UNIT
Volts Volts Volts Amp.
IFSM VF IR IR(H) Cj RθJA TJ TSTG
30 2.2 5.0 100 36 26 - 40 to + 150 - 40 to + 150
Amps. Volts µA µA pF °C/W °C °C
Typical Junction Capacitance (Note 1) Typical Thermal Resistance (Note 2) Junction Temperature Range Storage Temperature Range
Notes : (1) Measured at 1.0 MHz and applied reverse voltage of 4.0VDC (2) Thermal resistance from Junction to Ambient at 0.375" (9.5mm) Lead Lengths, P.C. Board Mounted.
UPDATE : AUGUST 1, 1998
RATING AND CHARACTERISTIC CURVES ( HVR112 - HVR120 )
FIG.1 - DERATING CURVE FOR OUTPUT RECTIFIED CURRENT
1.0 30
FIG.2 - MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT
AVERAGE FORWARD OUTPUT CURRENT, AMPERES
0.8
PEAK FORWARD SURGE CURRENT, AMPERES
0 25 50 75 100 125 150 175
24
0.6
18
0.4
12
0.2
6
0
0
1
2
4
6
10
20
40
60
100
AMBIENT TEMPERATURE, ( °C)
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
10
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
10 TJ = 100 °C
FORWARD CURRENT, AMPERES
REVERSE CURRENT, MICROAMPERES
1
1.0
0.1 Pulse Width = 300 µ s 1% Duty Cycle TJ = 25 °C 0.01 0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0
0.1 TJ = 25 °C
0.01 0 20 40 60 80 100 120 140
FORWARD VOLTAGE, VOLTS
PERCENT OF RATED REVERSE VOLTAGE, (%)
.