DatasheetsPDF.com

ENMOD Dataheets PDF



Part Number ENMOD
Manufacturers Vicor Corporation
Logo Vicor Corporation
Description ENMods Component Power Front End System for EN Compliance
Datasheet ENMOD DatasheetENMOD Datasheet (PDF)

PRELIMINARY 45 Features • Harmonic Current Attenuation to EN61000-3-2 • EMI Filtering to EN55022, Level B • Transient Immunity to EN61000-4-5 • 575W Rated Power Output • Autoranging 115/230Vac Input • Microprocessor Control • Inrush Current Limiting Data Sheet ENMods TM Component Power Front End System for EN Compliance Product Highlights The ENMods system is a new AC front end solution for compliance to electromagnetic compatibility (EMC) standards. It consists of the MiniHAM — a passive .

  ENMOD   ENMOD


Document
PRELIMINARY 45 Features • Harmonic Current Attenuation to EN61000-3-2 • EMI Filtering to EN55022, Level B • Transient Immunity to EN61000-4-5 • 575W Rated Power Output • Autoranging 115/230Vac Input • Microprocessor Control • Inrush Current Limiting Data Sheet ENMods TM Component Power Front End System for EN Compliance Product Highlights The ENMods system is a new AC front end solution for compliance to electromagnetic compatibility (EMC) standards. It consists of the MiniHAM — a passive harmonic attenuation module and the FARM3 — an auto ranging AC-DC front end module. Combined with the filtering and hold-up capacitors as specified herein, the ENMods system provides full compliance to: EN61000-3-2 Harmonic Current EN55022, Level B Conducted Emissions EN61000-4-5 Surge Immunity EN61000-4-11 Line Disturbances The MiniHAM is the first passive product specifically designed for compliance to EN harmonic current limits. Unlike active PFC solutions, the MiniHAM generates no EMI, greatly simplifying and reducing system noise filtering requirements. It is also considerably smaller and more efficient than active alternatives and improves MTBF by an order of magnitude. Optimized for operation on the DC bus (provided by the FARM3) rather than directly on the AC line, it will provide harmonic current compliance up to 600W of input power at 230Vac. The 115/230Vac input FARM3 is a new member of Vicor’s Filter and Autoranging Module product line that has been optimized for use as the front end for the MiniHAM. Both modules are in Vicor’s standard Mini half-brick package. Together with Vicor’s 1st or 2nd Generation 300V input DC-DC converters, they form the basis of a low noise, high efficiency, rugged, simple and reliable EN compliant power system. Each module: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Absolute Maximum Ratings Parameter L to N voltage (FARM3) L to N voltage (FARM3) +Out to –Out voltage (FARM3) BOK to –Out voltage (FARM3) EN to –Out voltage (FARM3) Mounting torque Pin soldering temperature Pin soldering temperature Output current Rating 264 280 400 16 16 4-6(0.45-0.68) 500 (260) 750 (390) 3.5 Unit Vrms Vrms Vdc Vdc Vdc in-lbs (N-m) °F (°C) °F (°C) A Notes Continuous 100ms 6 each, 4-40 screw <5 sec; wave solder <7 sec; hand solder Thermal Resistance Parameter Baseplate to sink; flat, greased surface Baseplate to sink; with thermal pad (P/N 20264) Baseplate to ambient Baseplate to ambient; 1000 LFM Typ 0.16 0.14 8.0 1.9 Unit °C/Watt °C/Watt °C/Watt °C/Watt Part Numbering EN1 Product Type* C Product Grade C = –20°C to +100°C T = –40°C to +100°C H = –40°C to +100°C M = –55°C to +100°C 1 Pin Style** 1 = Short Pin 2 = Long Pin S = Short ModuMate N = Long ModuMate 1 Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole *EN1 product includes one each MiniHAM and FARM3 with same product grade, pin and baseplate style. **Pin styles S & N are compatible with the ModuMate interconnect system for socketing and surface mounting. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ENMods System: FARM3 and MiniHAM Rev. 1.3 Page 1 of 12 Set your site on VICOR at www.vicorpower.com PRELIMINARY Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output power and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Performance specifications are based on the ENMods system as shown in Figure 1a. FARM3 MODULE SPECIFICATIONS (see Figure 3 thru Figure 7 for operating characteristics) Parameter Operating input voltage Operating input voltage Input undervoltage AC line frequency Power factor Inrush current Efficiency AC Bus OK (BOK) Low state resistance Low state current High state voltage BOK true threshold BOK false threshold Module Enable (EN) Low state resistance Low state current High state voltage Enable threshold Disable threshold AC Bus OK - Module Enable, differential error* 14.8 235 185 15 15.0 240 190 17 195 20 15 50 15.2 Ω mA Vdc Vdc Vdc Vdc 150k internal pull up to 15Vdc (see Figure 11) Output bus voltage Output bus voltage AC Bus OK and Module Enable thresholds track To negative output - Converters disabled 14.8 235 200 15.0 240 205 15 50 15.2 245 210 Ω mA Vdc Vdc Vdc To negative output - Bus normal Bus normal Bus abnormal, 27k internal pull up to 15Vdc (see Figure12) Output Bus voltage Output Bus voltage 94 96 47 0.68 0.72 30 Amps % Min 90 180 Typ 115 230 Max 132 264 90 63 Unit Vac Vac Vac Hz Notes Autoranging (doubler mode) Autoranging (bridge mode) No damage C-,T-, H- and M-Grade Typical line 264Vac line voltage Full load * Tracking error between BUS OK and Enable thresholds MINIHAM MODULE SPECIFICATIONS (when used in accordance with Figure 1a) Parameter Output power Efficiency @115Vac Efficiency @ 230Vac Output voltage External hold-up capacitance Min 0 93 96 250 94 97 375 3,300 Typ Max 575 Unit Watts % % Vdc µF Full load Full load Notes ELECTROMAG.


ENH050Q1-650 ENMOD ENN7385


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)