DatasheetsPDF.com

M-FIAM5HN1 Dataheets PDF



Part Number M-FIAM5HN1
Manufacturers Vicor Corporation
Logo Vicor Corporation
Description Military 28Vin Filter Input Attenuator Module
Datasheet M-FIAM5HN1 DatasheetM-FIAM5HN1 Datasheet (PDF)

45 Features • • • • • • • • • EMI filtering-MIL-STD-461E Transient protection-MIL-STD-704E 1 Environments-MIL-STD-810, MIL-STD-202 Environmental stress screening Low profile mounting options Output current up to 20 Amps Mini sized package Inrush current limiting Reverse polarity protection M-FIAM5 Military 28Vin Filter Input Attenuator Module Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Highlights The M-FIAM5 is a DC front-end module that provides EMI filtering and tra.

  M-FIAM5HN1   M-FIAM5HN1


Document
45 Features • • • • • • • • • EMI filtering-MIL-STD-461E Transient protection-MIL-STD-704E 1 Environments-MIL-STD-810, MIL-STD-202 Environmental stress screening Low profile mounting options Output current up to 20 Amps Mini sized package Inrush current limiting Reverse polarity protection M-FIAM5 Military 28Vin Filter Input Attenuator Module Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Highlights The M-FIAM5 is a DC front-end module that provides EMI filtering and transient protection required in military applications. The M-FIAM5 enables designers using Vicor 2nd Generation 24V DC-DC converters to meet conducted emission/conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704E1 . The M-FIAM5 accepts an input voltage of 18-36Vdc and delivers output current up to 20 Amps. M-FIAM5 is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications. Absolute Maximum Rating Parameter +In to –In +In to –In Mounting torque Pin Soldering temperature Pin Soldering temperature Operating temperature H–Grade Storage temperature H–Grade Operating temperature M–Grade Storage temperature M–Grade Rating 36 50 5(0.57) 500 (260) 750 (390) -40 to +100 -55 to +125 -55 to +100 -65 to +125 Unit Vdc Vdc in-lbs °F(°C) °F(°C) °C °C °C °C Notes Continuous 100ms 6 each, #4-40 or M3 <5 sec; wave solder <7 sec; hand solder Baseplate Baseplate Specifications (typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified) Compatible Products • 2nd Generation 24V Input DC-DC converters Part Number Format Parameter Input voltage Output current Inrush limiting Transient immunity EMI:MIL-STD-461E Conducted emissions: Conducted susceptibility: Dielectric withstand Efficiency Internal voltage drop ON/OFF control Enable (ON) Disable (OFF) External capacitance Weight Warranty 1 Min 18Vdc Typ 28Vdc MIL-STD-704E Max Remarks 36Vdc Continuous 20A 0.007A/µF See footnote 1 M-FIAM5 M Product 2 1 CE101, CE102 CS101, CS114, CS115, CS116 1,500Vrms 2,121Vdc 96% 98% 0.5 1.0 0.0Vdc 3.5Vdc 330µF 3.1 (88) 1.0Vdc 5.0Vdc 1000µF 4 (113) 2 Input/Output to Base Input/Output to Base @20A, 100°C baseplate Referenced to –Vout. 100kΩ internal pull-up resistor See illustration C1 on page 3. 50V Ounces (grams) Years Product Grade(°C) H = –40 to +100 M = –55 to +100 Pin Style 1 = Short 2 = Long *S=Short ModuMate *N=Long ModuMate Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole *Compatible with SurfMate and InMate socketing system. MIL-STD-704E Compliance requires an external circuit. See addendum A Thermal Resistance Parameter Typ Baseplate to sink; flat, greased surface 0.16°C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt Baseplate to ambient 7.9°C/Watt Baseplate to sink; 1000 LFM 2.2°C/Watt MTBF per MIL-HDBK-217F Temp 25°C 50°C 65°C Environment Ground Benign:G.B. Naval Sheltered:N.S. Airborne Inhabited Cargo:A.I.C. MTBF 3,334,295 786,893 650,187 Unit Hrs Hrs Hrs Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MFIAM5 Rev. 1.7 Page 1 of 5 Set your site on VICOR at www.vicorpower.com Environmental Qualification Altitude MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational. Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure I, Operational. Vibration MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 grams for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 grams for 1 hour per axis. Shock MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 G's, 9ms half sine. MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock. Acceleration MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 G's, 6 directions. Humidity MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH. Solder Test MIL-STD-202F, Method 208, 8 hour aging. Environmental Stress Screening Operating Temp. Storage Temp. Temp. Cycling:* Ambient Test @ 25°C Power Cycling Burn-In: Functional and Parametric ATE Tests: Hi-Pot Test Visual Inspection: Test Data H Grade -40°C to +100°C -55°C to +125°C 12 cycles -65°C to +100°C Yes 12 hours, 28 cycles -40°C and +100°C Yes Yes vicorpower.com M Grade -55°C to +100°C -65°C to +125°C 12 cycles -65°C to +100°C Yes 24 hours, 56 cycles -55°C and +100°C Yes Yes vicorpower.com *Temperature cycled with power off, 17°C per minute rate of change. Conducted Noise Figure 1– M-FIAM5 and Model V24A12M400A DC-DC converter operating at 28Vdc, 400W. Transient Immunity Inrush Limiting Figure 2 – Transient Immunity: M-FIAM5 output response to an input transient. Vicor Corp. Tel: 800-735-6200, 978-470-29.


M-FIAM5H23 M-FIAM5HN1 M-FIAM5HN2


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)