n Leadless, surface mount for economical assembly n Compact mini-size n Low capacitance and insertion loss n RoHS compliant* n UL Recognized
LEAD FREE
2003 Series Gas Discharge Tube Surge Protector
Bourns offers a low-cost surface mount (SM) 2-electrode GDT surge protection device. The 2003 Series is ideal for broadband protection due to its ultra-low capacitance. The 2003 Series offers superior protection characteristics suitable for telecommunications, commercial and industrial applications.
RoHSV ECROSLIMEOPALNIDS A FANRTRE*EE
Characteristics Test Methods per ITU-T (CCITT) K.12 and IEEE C62.31
Characteristic DC Sparkover ± 20 % @ 100 V/s Maximum Impulse Breakdown Voltage
100V/μs 1000V/μs DC Holdover Voltage <150 ms
2003-07 75 V
600 V 700 V
52 V
2003-09 90 V
600 V 700 V
52 V
Model No. 2003-12 120 V
600 V 700 V
80 V
2003-15 150 V
600 V 700 V
80 V
2003-20 200 V
600 V 700 V
135 V
Characteristic DC Sparkover ± 20 % @ 100 V/.