Isolation Transformer
Document 1022
Isolation Transformer ForTexasInstrumentsSN6501 Transformer Driver
• Developed to work with Texas Instru...
Description
Document 1022
Isolation Transformer ForTexasInstrumentsSN6501 Transformer Driver
Developed to work with Texas Instruments SN6501 Transformer Driver for Isolated Power Supplies
Center tapped primary and secondary windings Designed to meet UL/CSA/IEC 60950 Basic Insulation with
1.5 mm creepage and clearance. Core material Ferrite Terminations RoHS tin-silver over tin over nickel over phos bronze. Other terminations available at additional cost. Weight 0.98 g Ambient temperature –40°C to +125°C Storage temperature Component: –40°C to +125°C. Tape and reel packaging: –40°C to +80°C Isolation 2500 Vrms, one minute, winding to winding Resistance to soldering heat Max three 40 second reflows at +260°C, parts cooled to room temperature between cycles Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C / 85% relative humidity) Failures in Time (FIT) / Mean Time Between Failures (MTBF) 38 per billion hours / 26,315,789 hours, calcul...