60W PoE Transformers
Document 1215-1
60 W PoE Transformers ForActiveClamp Forward Topology
• Designed for active clamp forward topology • ...
Description
Document 1215-1
60 W PoE Transformers ForActiveClamp Forward Topology
Designed for active clamp forward topology Operates at 200 kHz, with 36 – 72 Volt input Includes a 12-Volt auxiliary winding Isolation: 1500 Vrms, one minute primary and aux to secondary;
500 Vrms primary to auxiliary
Core material Ferrite Terminations RoHS tin-silver over tin over nickel over phos bronze. Other terminations available at additional cost. Weight 12.7 g Ambient temperature –40°C to +125°C Storage temperature Component: –40°C to +125°C. Tape and reel packaging: –40°C to +80°C Resistance to soldering heat Max three 40 second reflows at +260°C, parts cooled to room temperature between cycles Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C / 85% relative humidity) Failures in Time (FIT) / Mean Time Between Failures (MTBF) 38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332 Packaging 175 per 13″ reel Pl...