Document
SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 6.0 Amperes
BR605 THRU BR610
FEATURES
* Surge overload rating :175 amperes peak * Low forward voltage drop * Small size :simple installation * Mounting position: Any * Mounting: Hole thru for #6 screw * Mounting Torque : 8 KgF/cm(max.) * Recommended Torque : 6 KgF/cm
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O * UL list the recognized component directory,file #E94233
.042 (1.07) DIA.
.038 (0.97)
BR-6
.270(6.84) .230(5.84)
.750 MIN.
(19.0)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified.
resistive or inductive load.
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TC = 75 oC (with heat sink) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method)
Current Squarad Time
SYMBOL VRRM VRMS VDC IO
IFSM I2t
BR605 50 35 50
Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range
Rθ JC Rθ JA TJ, TSTG
ELECTRICAL CHARACTERISTICS(@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 3.0A DC
Maximum DC Reverse Current at Rated DC Blocking Voltage
@TA = 25oC @TA = 150oC
SYMBOL VF
IR
BR605
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. " ROHS compliant"
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
BR61 100 70 100
BR61
.620 (15.7) .580 (14.7) .445 (11.3) .405 (10.3)
.158 (4.0) .154 (3.9)
AC .445 (11.3)
.405 (10.3)
.620 (15.7) .580 (14.7)
AC
Dimensions in inches and (millimeters)
BR62 200 140 200
BR64 400 280 400
6.0
BR66 600 420 600
175
127 7.3 25 -55 to + 150
BR68 800 560 800
BR610 1000 700 1000
UNITS Volts Volts Volts
Amps
Amps A2/Sec
0C/W
0C
BR62
BR64 1.1
5.0 10
BR66
BR68
BR610
UNITS Volts uAmps
mAmps
2019-12 REV:E
RATING AND CHARACTERISTICS CURVES ( BR605 THRU BR610 )
AVERAGE FORWARD CURRENT, (A)
6.0
4.8
3.6
2.4
1.2
Single Phase Half Wave 60 Hz Inductive or
Resistive Load
0 0
100000
50 100
CASE TEMPERATURE, (OC)
FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE
150
10000
TA = 150 OC
100
10 TA = 25 OC
1.0 0 20 40 60 80 100 120 140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 MAXIMUM REVERSE CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
40
10 4
1
0.4 TA = 25 OC Pulse Width = 300mS 1% Duty Cycle
0.1 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.2 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
180 8.3mS Single Half Sine-Wave
150 JEDEC Method
120 90
60
30
0 12
5 10 20
50 100
NUMBER OF CYCLES AT 60Hz
FIG.4 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
INSTANTANEOUS REVERSE CURRENT, (uA)
Marking Description
Rectron Logo
UL Logo Year – code (Y:Last digit of year)
BR6X
VYWW
Week-code (WW:01~52)
Part No. Voltage-code
05-------50V 6-------600V 1-------100V 8-------800V 2-------200V 10-----1000V 4-------400V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE CARTON SIZE EA PER CARTON
(mm)
(mm)
BR-3/-6
-B
200
206*208*55
450*220*255
2,000
GROSS WEIGHT(Kg)
7.50/8.50
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
.