Document
RG402 Coax Cable with Copper Outer Conductor
TECHNICAL DATA SHEET
RG402 Coax Cable with Copper Outer Conductor
Configuration Inner Conductor Material and Plating Dielectric Type Shield Materials Jacket Material and Color
Electrical Specifications Impedance, Ohms Maximum Operating Frequency, GHz Capacitance, pF/ft [pF/m] Dielectric Withstanding Voltage, Vrms
Copper Clad Steel, Silver PTFE Copper Tan
50 36 29.9 [98.1] 5,000
RG402/U
Electrical Specifications by Frequency Frequency 1 Frequency, MHz Attenuation, dB/100ft [dB/100m] Power Handling, Watts
Frequency 2 Frequency, GHz Attenuation, dB/100ft [dB/100m] Power Handling, Watts
Frequency 3 Frequency, GHz Attenuation, dB/100ft [dB/100m] Power Handling, Watts
1000 12 [39.37] 450
10 45 [147.64] 120
20 70 [229.66] 70
Mechanical Specifications
Temperature Operating Range, deg C
-55 to +125
Inner Conductor
Number of Strands
1
Material
Copper Clad Steel
Plating Silver
Diameter, in [mm]
0.036 [0.91]
Diele.