Document
Coaxial-Flex
Test Cables
50Ω DC to 18 GHz
Features
• wideband coverage, DC to 18 GHz • extra rugged construction with strain relief for longer life • stainless steel SMA and Type N connectors for long mating-cycle life • useful over temperature range, -55°C to 105°C • triple shield cable for excellent shielding effectiveness • flexible for easy connection & bend radius • superior stability of insertion loss, VSWR & phase vs. flexing • 6 month guarantee*
New!
CBL-SERIES
IN STOCK
Applications
• high volume production test stations • research & development labs • environmental & temperature test chambers • replacement for OEM test port cables • field RF testing • cellular infrastructure site testing
CBL-SMNM (SMA-N MALE)
CBL-SMSM (SMA MALE)
CBL-NMNM (N-MALE)
Electrical Specifications at 25°C
MODEL NO. CONNECTOR FREQ. LENGTH TYPE (GHz) (FT) (MALE) fL-fU
CONN 1 CONN 2 2 3 6 2 3 6 2 3 6
INSERTION LOSS (dB)
DC-2.5 GHz 2.5-6 GHz 6-12 GHz 12-18 GHz DC-2.5 GHz Min. 23 23 23 23 23 23 23 23 23
RETURN LOSS (dB)
2.5-6 GHz Typ. 30 30 30 30 30 30 30 30 30 Min. 20 20 20 20 20 20 20 20 20 6-12 GHz Typ. 27 27 27 27 27 27 27 27 27 Min. 17 17 17 17 17 17 17 17 17 12-18 GHz Typ. 27 27 22 27 27 22 27 27 22 Min. 17 17 17 17 17 17 17 17 17
CASE PRICE STYLE $ Qty. (1-9)
CBL-2FT-SMSM SMA SMA DC-18 CBL-3FT-SMSM SMA SMA DC-18 CBL-6FT-SMSM SMA SMA DC-18 CBL-2FT-SMNM SMA N-TYPE DC-18 CBL-3FT-SMNM SMA N-TYPE DC-18 CBL-6FT-SMNM SMA N-TYPE DC-18 CBL-2FT-NMNM N-TYPE N-TYPE DC-18 CBL-3FT-NMNM N-TYPE N-TYPE DC-18 CBL-6FT-NMNM N-TYPE N-TYPE DC-18 Custom sizes available, consult factory.
Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. 0.4 0.6 0.7 0.85 1.1 1.25 1.4 1.6 30 0.6 0.8 1.0 1.2 1.5 1.8 1.9 2.25 30 1.2 1.4 2.0 2.2 3.0 3.35 3.8 4.3 30 0.4 0.6 0.7 0.9 1.1 1.25 1.4 1.6 30 0.6 0.8 1.0 1.3 1.5 1.8 1.9 2.25 30 1.2 1.4 2.0 2.3 3.0 3.35 3.8 4.3 30 0.4 0.6 0.7 0.85 1.1 1.25 1.4 1.6 30 0.6 0.8 1.0 1.2 1.5 1.8 1.9 2.25 30 1.2 1.4 2.0 2.2 3.0 3.35 3.8 4.3 30
GM1006-2 GM1006-3 GM1006-6 GM1105-2 GM1105-3 GM1105-6 GM1106-2 GM1106-3 GM1106-6
69.95 72.95 79.95 99.95 104.95 114.95 102.95 105.95 112.95
Maximum Ratings
Operating Temperature Storage Temperature
Jacket
Outer Shield
-55°C to 105°C -55°C to 105°C
Interlayer Shield Inner Conductor
Inner Shield
Dialectric
cable cross section Product Guarantee* Mini-Circuits will repair or replace your test cable at its
®
Cable Construction
Inner Conductor Dielectric Shield Solid Silver Plated Copper Clad Steel Solid PTFE Silver-Plated Copper Flat Ribbon Braid Aluminum-Polymide Tape Interlayer 36 GA Silver-Plated Copper Braid (90%k) Clear FEP
option if the connector attachment fails within six months of shipment. This guarantee excludes cable or connector interface damage from misuse or abuse.
Jacket
Connectors
• passivated stainless steel • captive contact • thick wall interface (SMA) • gold plated beryllium copper center contacts • PTFE dielectric