Document
SB6G, SBT6G SERIES
Single Phase 6.0 AMPS. Glass Passivated Bridge Rectifiers
Voltage Range 50 to 1000 Volts
Current 6.0 Amperes
SBT-6
SB-6
Features
UL Recognized File # E-96005
Glass passivated junction
Surge overload rating 175 amperes peak
Low forward voltage drop
Mounting position: Any
High temperature soldering guaranteed:
260℃ / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs., ( 2.3 kg ) tension
Small size, simple installation
Leads solderable per MIL-STD-202
Method 208
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%
Type Number
Symbol
SB 601G
SBT 601G
SB 602G
SBT 602G
SB 603G
SBT 603G
SB 604G
SBT 604G
SB 605G
SBT 605G
SB 606G
SBT 606G
SB 607G
SBT 607G
Units
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS Voltage
VRMS 35 70 140 280 420 560 700 V
Maximum DC Blocking Voltage
VDC 50 100 200 400 600 800 1000 V
Maximum Average Forward Rectified Current @TA = 50℃
I(AV)
6.0
A
Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method )
IFSM
175
A
Maximum Instantaneous Forward Voltage @ 3.0A
VF
1.1
V
Maximum DC Reverse Current @ TA=25℃ at Rated DC Blocking Voltage @ TA=125℃
IR
10 uA 500 uA
Typical Thermal Resistance (Note 1) (Note 2)
RθJA RθJL
22 ℃/W 7.3
Operating Temperature Range
TJ
-55 to +150
℃
Storage Temperature Range
TSTG
-55 to +150
℃
Note: 1. Unit Mounted on P.C.B. at 0.375” (9.5mm) Lead Length with 0.5” x 0.5” (12mm x 12mm) Copper Pads.
2. Unit Mounted on 2” x 3” x 0.25” Al. Plate.
- 662 -
PEAK FORWARD SURGE CURRENT. (A)
RATINGS AND CHARACTERISTIC CURVES ( SB601G THRU SB607G )
SBT601G
SBT607G
FIG.1- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER BRIDGE ELEMENT
250
FIG.2- TYPICAL FORWARD CURRENT DERATING CURVE
10
AVERAGE FORWARD OUTPUT CURRENT AMPERES
200 8 175
150 6
100 4
50 2
0 1
2
4 6 8 10
20
NUMBER OF CYCLES AT 60Hz
40 60 80 100
FIG.3- TYPICAL FORWARD CHARACTERISTICS PER BRIDGE ELEMENT
100
0 0 50 100 AMBIENT TEMPERATURE. (oC)
FIG.4- TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT
100
150
INSTANTANEOUS REVERSE CURRENT, MICROAMPERES
10
1.0
Tj=250C PULSE WIDTH-300 S 1% DUTY CYCLE
0.1
0.01 .6
.8 1.0 1.2 1.4 1.6 FORWARD VOLTAGE. VOLTS
1.8
2.0
TJ=1250C 10
1
TJ=250C
0.1 0
20 40 60 80 100 120
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
140
INSTANTANEOUS FORWARD CURRENT AMPERES