Document
CM420890
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
SCR/Diode POW-R-BLOK™ Modules
90 Amperes/800 Volts
A B A1K2 K1 A2 H
K1 G1
D
L - DIA. (2 TYP.)
G
F
F
M - M5 THD (3 TYP.)
.110 TAB
J
Description: Powerex SCR/Diode POW-R-BLOK™ Modules are designed for use in applications requiring Half-Control and isolated packaging. The modules are isolated for easy mounting with other components on common heatsinks. Features:
CM420890 SCR/Diode POW-R-BLOK™ Modules 90 Amperes/800 Volts
C
E
K
Ⅺ Isolated Mounting Ⅺ Glass Passivated Chips Ⅺ Metal Baseplate Ⅺ Low Thermal Impedance
A1K2
K1
A2 K1 G1
Outline Drawing
Applications: Ⅺ Battery Supplies
Dimension A B C D E F G H J K L M
Inches 3.681 3.150±0.012 1.181 1.024 0.827 0.787 0.689 0.492 0.354 0.256
Millimeters 93.5 80±0.3 30 26 21 20 17.5 12.5 9 6.5
Ⅺ Bridge Circuits Ⅺ AC and DC Motor Control Ⅺ Tap Changers Ⅺ Lighting Control Ordering Information: Select the complete eight digit module part number you desire from the table below. Example: CM420890 is a 800 Volt, 90 Ampere SCR/Diode POW-R-BLOK™ Module.
Type CM42 Voltage Volts (x100) 08 Current Rating Amperes (90) 90
0.256±0.008 Dia. Dia. 6.5±0.2 M5 Metric M5
SD-17
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM420890 SCR/Diode POW-R-BLOK™ Modules 90 Amperes/800 Volts
Absolute Maximum Ratings
Characteristics Peak Forward Blocking Voltage Transient Peak Forward Blocking Voltage (Non-Repetitive), t < 5ms DC Forward Blocking Voltage Peak Reverse Blocking Voltage Transient Peak Reverse Blocking Voltage (Non-Repetitive), t < 5ms DC Reverse Blocking Voltage RMS On-State Current Average On-State Current, TC = 86°C Peak One-Cycle Surge (Non-Repetitive) On-State Current (60Hz) Peak One-Cycle Surge (Non-Repetitive) On-State Current (50Hz) I2t (for Fusing), 8.3 milliseconds Critical Rate-of-Rise of On-State Current* Peak Gate Power Dissipation Average Gate Power Dissipation Peak Forward Gate Voltage Peak Reverse Gate Voltage Peak Forward Gate Current Storage Temperature Operating Temperature Maximum Mounting Torque M6 Mounting Screw Maximum Mounting Torque M5 Terminal Screw Module Weight (Typical) V Isolation
*Tj = 125°C, IG = 1.0A, VD = 1/2 VDRM
Symbol VDRM VDSM VD(DC) VRRM VRSM VR(DC) IT(RMS), IF(RMS) IT(AV), IF(AV) ITSM, IFSM ITSM, IFSM I2t di/dt PGM PG(AV) VGFM VGRM IGFM TSTG Tj — — — VRMS
CM420890 800 960 640 800 960 640 140 90 1800 1730 15000 100 5.0 0.5 10 5.0 2.0 -40 to 125 -40 to 125 26 17 160 2000
Units Volts Volts Volts Volts Volts Volts Amperes Amperes Amperes Amperes A2sec Amperes/s Watts Watts Volts Volts Amperes °C °C in.-lb. in.-lb. Grams Volts
Electrical and Thermal Characteristics, Tj = 25°C unless otherwise specified
Characteristics Blocking State Maximums Forward Leakage Current, Peak Reverse Leakage Current, Peak Conducting State Maximums Peak On-State Voltage Switching Minimums Critical Rate-of-Rise of Off-State Voltage Thermal Maximums Thermal Resistance, Junction-to-Case Thermal Resistance, Case-to-Sink (Lubricated) Gate Parameters Maximums Gate Current-to-Trigger Gate Voltage-to-Trigger Non-Triggering Gate Voltage Symbol IDRM IRRM VFM, VTM dv/dt R(J-C) R(C-S) IGT VGT VGDM Test Conditions Tj = 125°C, VDRM = Rated Tj = 125°C, VRRM = Rated IFM = 270A, ITM = 270A Tj = 125°C, VD = 2/3 VDRM Per Module Per Module VD = 6V, RL = 2Ω VD = 6V, RL = 2Ω Tj = 125°C, VD = 1/2 VDRM CM420890 15 15 1.3 500 0.3 0.2 100 3.0 0.25 Units mA mA Volts Volts/s °C/Watt °C/Watt mA Volts Volts
SD-18
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM420890 SCR/Diode POW-R-BLOK™ Modules 90 Amperes/800 Volts
MAXIMUM ON-STATE CHARACTERISTICS
INSTANTANEOUS ON-STATE VOLTAGE, VTM, (VOLTS)
MAXIMUM ALLOWABLE PEAK SURGE (NON-REPETITIVE) CURRENT
MAXIMUM ALLOWABLE CASE TEMPERATURE (SINUSOIDAL WAVEFORM)
MAXIMUM ALLOWABLE CASE TEMPERATURE, TC, (oC)
2.4
MAXIMUM PEAK SURGE (NON-REPETITIVE) CURRENT, ITSM, (AMPERES)
2000
Tj = 125oC
130 120 110 100 90 80 70
= 30o 60o 90o 120o 180o
360o RESISTIVE, INDUCTIVE LOAD PER SINGLE ELEMENT
2.0
1600
1.6
1200
1.2
800
0.8
400
60 50 0 20 40 60 80 100
AVERAGE ON-STATE CURRENT, IT(AV), (AMPERES)
0.4 100
101
102
103
0 100
101
CYCLES AT 60 HZ
102
INSTANTANEOUS ON-STATE CURRENT, ITM, (AMPERES)
MAXIMUM ON-STATE POWER DISSIPATION (SINUSOIDAL WAVEFORM)
MAXIMUM POWER DISSIPATION, PAV(MAX), (WATTS)
MAXIMUM ALLOWABLE CASE TEMPERATURE (RECTANGULAR WAVEFORM)
MAXIMUM ALLOWABLE CASE TEMPERATURE, TC, (oC) MAXIMUM POWER DISSIPATION, PAV(MAX), (WATTS)
MAXIMUM AVERAGE ON-STATE POWER DISSIPATION (RECTANGULAR WAVEFORM)
160 140 120 100 80 60 40 20 0 0 20 40 60 80 100
AVERAGE ON-STATE CURRENT, IT(AV), (AMPERES) 360o RESISTIVE, INDUCTIVE LOAD PER SINGLE ELEMENT
130 120 110 100 90 80 70
= 30o 60o 90o 120o 180o 270o DC
360o RESISTIVE, INDUCTIVE LOAD PER SINGLE ELEMENT
160
DC
140 120 100 80 60 40 20 0 0 20 40 60
= 30o 60o 120o 90o 180o
270o
180o 120o 90o 60o
.