voltage transformer operating guide
ZMPT101B(ZMPT107) voltage transformer operating guide
1、Wiring diagram
FigureⅠ
Figure Ⅱ
2、Determination of maximum ou...
Description
ZMPT101B(ZMPT107) voltage transformer operating guide
1、Wiring diagram
FigureⅠ
Figure Ⅱ
2、Determination of maximum output rms voltage
Umax:
Umax is decided by the AD peak voltage in the
sampling loop in principle.
Peakvoltag e
As for Bipolar AD,Umax= 2
peak voltage
As for unipolar AD,Umax= 2 2
for example: As for ± 5V AD,the maximum rms voltage of
the transformer: Umax = 5V / 2 =3.53V As for 0~3.3V AD,the maximum rms voltage of
the transformer:V max = 3.3V / 2 2 =1.16V
3、Determination of input current-limiting resistor R′
Current-limiting resistor R′= V
I
V:Rated input voltage
I : Rated operating current ( when Coil
resistance is compared with current-limiting
resistor R′ , it can be ignored.)
ZMPT101B/ZMPT107 usually working at rated
current:1~2mA.
When
Rated
input
voltage≤100V , Usually choosing the operating
current
I=2mA; When
Rated input
voltage≥220V,To reducing the resistor power,
Usually choosing the operating current 1 mA
≤I≤2 mA. for example: V=100V,I=2 mA,
R′= V =50K Ω
I
for example: V=220V,I=1.1mA,
R′= V =200 kΩ
I
To improve reliability, the current-limiting resistor selected usually is greater than its 4times the rated power, and generally use a high
temperature coefficient metal film resistor.
4、Determination of the sampling resistor R
VR = V R= outputmax outputmax
I Vinputmax
for example: Voutput max =3.53V,Vinput max =120V, R′ =50 kΩ
Directions:
R= 3.53 ×50 k Ω =1.471 kΩ
120
(1) Above formula is also suitable for the two
ways of a...