Document
Elektronische Bauelemente
RS601 THRU RS607
VOLTAGE 50V ~ 1000V 6.0AMP Single Phase Bridge Rectifiers
FEATURES
* Ideal for printed circuit board * Low forward voltage * Low leakage current * Polarity: marked on body * Mounting position: Any
RS-6
.935(23.7) .895(22.7)
.15FX.23L
(3.8FX5.7L) HOLE THRU
.700(17.8) .660(16.8)
1.00 (25.4)
MIN.
.078 (2.0)
.780(19.8) .740(18.8)
AC +
.052(1.3) .048(1.2)
DIA.
.220(5.6) .180(4.6)
SPACING
.280(7.1) .268(6.8)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current
RS601 RS602 RS603 RS604 RS605 RS606 RS607 UNITS
50 100 200 400 600 800 1000 V 35 70 140 280 420 560 700 V 50 100 200 400 600 800 1000 V
.375"(9.5mm) Lead Length at Tc=50 C Peak Forward Surge Current, 8.3 ms single half sine-wave
6.0 A
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 6.0A D.C.
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage Operating Temperature Range, TJ Storage Temperature Range, TSTG
Ta=100 C
250 1.0 10
200 -65 +125 -65 +150
A V µA
µA C C
http://www.SeCoSGmbH.com
Any changing of specification will not be informed individual
AVERAGE FORWARD CURRENT,(A)
Elektronische Bauelemente
RS601 THRU RS607
VOLTAGE 50V ~ 1000V 6.0AMP Single Phase Bridge Rectifiers
RATING AND CHARACTERISTIC CURVES (RS601 THRU RS607)
FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE
6 5 4 3 Single Phase
Half Wave 60Hz Resistive Or Inductive Load 2
1 0
0 25 50 75 100 125 150 175
CASE TEMPERATURE,( C)
PEAK FORWARD SURGE CURRENT,(A)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
250
200
150
100
50
0 1
Tj=25 C
8.3ms Single Half Sine Wave JEDEC method
5 10 NUMBER OF CYCLES AT 60Hz
50 100
FIG.3-TYPICAL FORWARD CHARACTERISTICS
50
10 3.0 1.0
0.1
Tj=25 C
Pulse Width 300us 1% Duty Cycle
.01 0
.2 .4 .6 .8 1.0 1.2 1.4
FORWARD VOLTAGE,(V)
REVERSE LEAKAGE CURRENT, (mA)
FIG.4-TYPICAL REVERSE CHARACTERISTICS
50
10 3.0 Tj=100 C 1.0
0.1
Tj=25 C
.01 0 20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
INSTANTANEOUS FORWARD CURRENT,(A)
http://www.SeCoSGmbH.com
Any changing of specification will not be informed individual
.