Document
Series AM5TW-RVZ
5 Watt | DC-DC Converter
Models Single output
Model
AM5TW-2403S-RVZ AM5TW-2405S-RVZ AM5TW-2412S-RVZ AM5TW-2415S-RVZ AM5TW-4803S-RVZ AM5TW-4805S-RVZ AM5TW-4812S-RVZ AM5TW-4815S-RVZ
FEATURES:
• Wide Input Range (4:1) • 24 Pin DIP Package • Metal package • High efficiency up to 82%
• Operating temperature -40oC to + 85oC • Input / Output isolation 1500 VDC • Pin compatible with multiple manufacturers • Continuous short circuit protection
Input Voltage (V)
9-36 9-36 9-36 9-36 18-72
18-72 18-72 18-72
Output Voltage (V)
3.3 5 12 15 3.3
5 12 15
Output Current max (mA)
1200 1000
416 333 1200 1000 416 333
Capacitive load, max (μF)
2200 1000 470 330 2200
1000 470 330
Efficiency (%)
70 73
74 74 68 73 74 76
Models Dual output
Model
AM5TW-2405D-RVZ AM5TW-2412D-RVZ AM5TW-2415D-RVZ AM5TW-4805D-RVZ AM5TW-4812D-RVZ AM5TW-4815D-RVZ
Input Voltage (V)
9-36
9-36
9-36 18-72 18-72 18-72
Output Voltage (V)
±5
±12
±15 ±5 ±12 ±15
Output Current max (mA)
±500
±208
±166 ±500 ±208 ±166
Capacitive load, max (μF)
±470
±100
±68 ±470 ±100 ±68
Efficiency (%)
77
82
82 72 75 75
Input Specifications
Parameters
Voltage Range
Filter Start up time Peak Input Voltage time Absolute Max Rating
Nominal
24 48
24 Vin
Typical
9-36 18-72
20 15 -0.7-40
Maximum
π (Pi) Network
Units
VDC
Ms Ms VDC
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3 sec
Typical
> 1000 60
Rated
1500
Units
VDC MOhm
pF
Output Specifications
Parameters
Voltage Balance Voltage accuracy Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise
Conditions
Balanced Load
At 20MHz Bandwidth
Typical
Maximum
±1
±1
Continuous
Auto Recovery
±0.5
±0.5
±0.02
60
Units
% %
% % %/oC mV p-p
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722 1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM5TW-RVZ
5 Watt | DC-DC Converter
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency Operating temperature Storage temperature Max Case temperature
100% load Full Load (see derating chart)
100-400
-40 to +85 -40 to +125
100
KHz oC oC oC
Cooling
Free air convection
Humidity
95 %
Case material
Nickel coated copper
Weight
15 g
Dimensions(L x W x H) Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches 31.75 x 20.32 x 10.16 mm
MTBF
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Pin Out Specifications
Pin 1500 VDC
Single
Dual
2 -V Input
-V Input
3 -V Input
-V Input
9 No pin
Common
11 N.C.
-V Output
14 +V Output
+V Output
16 -V Output
Common
22 +V Input
+V Input
23 +V Input
+V Input
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722 2 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Dimensions
31.75 (1.25)
0.50 (0.02)
22.86 (0.90)
20.32 (0.80)
2.54 (0.10)
23
9 11
Bottom View
23 22
16 14
Printed Face
Built-in Stand-offs to ease PCB cleaning
5.08 (0.20)
15.24 (0.60)
Series AM5TW-RVZ
5 Watt | DC-DC Converter
10.16 (0.40)
3.05 (0.12)
Derating 100
Free Air Convection
85 º C
Output Power %
80
60
Safe Operating Area
40
20
0 -40 0 25 50 75 85 100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722 3 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
.