H U IK E
1. : Safety Standard:
C-UL CQC TUV
HK19F
Page: 1
2. : Contact Specification: 2.1 : Contact Gap: 2.2 : Conta...
H U IK E
1. : Safety Standard:
C-UL CQC TUV
HK19F
Page: 1
2. : Contact Specification: 2.1 : Contact Gap: 2.2 : Contact Resistance
2.3 : Contact Capacity:
0.15mm。 0.15mm Minimum.
100mΩ; 1A、: 6VDC; 。 Maximum 100mΩ at initial value. Test Current: 1A, Open Circuit Test Voltage: 6VDC. By using Voltage Drop Method.
125VAC Cosφ=1, 1 。 24VDC, 1 。 1 Amps at 125VAC Cosφ=1. 1Amps at 24VDC .
3. 20 : Coil Specification at 20 °C:
3.1 :
Rated Voltage:
3.2 :( mA± 10%)
Nominal Current:
3.3 :
(±
10%.)
Rated Power
Consumption:
3.4 : (Ω± 10%.)
Coil Resistance:
3VDC. 5VDC.
6VDC.
9VDC.
12VDC.
24VDC
50/67/120 29.9 /40/72 25/33.3/60 16.7/22.5/40 12.5/16.7/30 6.25/8.3/15
0.15W/0.2W0.36W
60/45/25 167/125/70 240/180/100 540/400/220 960/720/400 3840/2880/1600
3.5 : Pull In Voltage:
≦ (, 80%) V DC
≦ (Contact operating voltage when voltage is gradually applied. It is 80% of the Rated Voltage) V DC
3.6 : Drop Out Voltage:
≧ (, 10%) VDC ≧ (Contact breaking voltage when rated voltage is gradually reduced. It is 10% of the Rated Voltage) VDC
3.7 :
Max. Allowable Voltage:
( 130%) V DC (130% of the Rated Voltage) V DC
3.8 : Operate Time:
6milliseconds。 6milliseconds Maximum when rated Voltage is applied.
Http:// www.cnomron.com
:0755-28236318、28236328、28236338
B412B E-mail:
[email protected] :0755-28236462
H U IK E
HK19F
Page: 2
3.9 Release Time:
4 milliseconds.。 4milliseconds Maximum when rated Voltage is suddenly cut off.
3.10 : Coil Temperature Rise:
, 40℃。(
)...