4-Channel Multiplexer
Data Sheet
Fault Protection and Detection, 10 Ω RON, 4-Channel Multiplexer
ADG5404F
FEATURES
Overvoltage protection up...
Description
Data Sheet
Fault Protection and Detection, 10 Ω RON, 4-Channel Multiplexer
ADG5404F
FEATURES
Overvoltage protection up to −55 V and +55 V Power-off protection up to −55 V and +55 V Overvoltage detection on source pins Interrupt flags indicate fault status Low on resistance: 10 Ω (typical)
On-resistance flatness of 0.5 Ω (maximum) 4 kV human body model (HBM) ESD rating Latch-up immune under any circumstance Known state without digital inputs present VSS to VDD analog signal range
±5 V to ±22 V dual supply operation 8 V to 44 V single-supply operation Fully specified at ±15 V, ±20 V, 12 V, and 36 V
APPLICATIONS
Analog input/output modules Process control/distributed control systems Data acquisition Instrumentation Avionics Automatic test equipment Communication systems Relay replacement
GENERAL DESCRIPTION
The ADG5404F is an analog multiplexer composed of four single channels with fault protected inputs. The ADG5404F switches one of the four inputs to a common drain, D, as determined by the 2-bit binary address lines (A0 and A1). An enable digital input, EN, is used to disable all the switches. Each channel conducts equally well in both directions when on, and each switch has an input signal range that extends to the supplies. The digital inputs are compatible with 3 V logic inputs over the full operating supply range.
When no power supplies are present, the switch remains in the off condition, and the channel inputs are high impedance. Under normal operating conditions, if t...