5 Port Solenoid Valve
Series SY3000/5000/7000/9000
Rubber Seal
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
Cover (stainless steel)
Improved pilot valve
Pilot valve cover is stronger using stainless steel.
Mounting thread is also reinforced from size M1.7 to M2.
ț Flow Characteristics
Series
SY3000
SY5000
SY7000
SY9000
Flow characteristics
C [dm3/(s·bar)]
b
1.1 0.28
2.8 0.37
4.5 0.28
10 0.29
Cv
0.29
0.90
1.4
2.5
101


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Cylinder Speed Chart
Body Ported
Series
SY3120-C6
SY5120-01
SY7120-02
SY9120-03
Series CJ2
Average Pressure 0.5 MPa
speed Load rate: 50%
(mm/s) Stroke 60 mm
ø6 ø10 ø16
800
700
600
500
400
300
200
100
0
800
700
600
500
400
300
200
100
0
800
700
600
500
400
300
200
100
0
800
700
600
500
400
300
200
100
0
Series CM2
Pressure 0.5 MPa
Load rate: 50%
Stroke 300 mm
ø20 ø25 ø32
Use as a guide for selection.
Please confirm the actual conditions with SMC Sizing
Program.
Bore size
Series MB, CA2
Pressure 0.5 MPa
Load rate: 50%
Stroke 500 mm
ø40 ø40 ø50 ø63
ø80
ø100
Series CS1
Pressure 0.5 MPa
Load rate: 50%
Stroke 1000 mm
ø125 ø140 ø160
Perpendicular,
upward actuation
Horizontal actuation
ȢȢ
Base Mounted
Bore size
Series
SY3140-01
SY5140-02
SY7140-03
SY9140-04
Average
speed
(mm/s)
800
700
600
500
400
300
200
100
0
800
700
600
500
400
300
200
100
0
800
700
600
500
400
300
200
100
0
800
700
600
500
400
300
200
100
0
Series CJ2
Pressure 0.5 MPa
Load rate: 50%
Stroke 60 mm
ø6 ø10 ø16
Series CM2
Series MB, CA2
Series CS1
Pressure 0.5 MPa
Pressure 0.5 MPa
Pressure 0.5 MPa
Load rate: 50%
Load rate: 50%
Load rate: 50%
Stroke 300 mm
Stroke 500 mm
Stroke 1000 mm
ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160 ø180
Perpendicular,
upward actuation
Horizontal actuation
ȢȢ
ȢȢȢ
Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
Load factor: ( (Load weight x 9.8) /Theoretical force) x 100%
The histograms with Ȣ marked are the case when piping is done by using steel.
ø200
Ȣ
Conditions
Body ported
Series CJ2 Series CM2 Series MB, CA2 Series CS1
Tubing bore x Length
T0604 x 1 m
SY3120-C6 Speed controller
AS2051F-06
Silencer
AN120-M5
Tubing bore x Length T0604 x 1 m T0806 x 1 m
SY5120-01 Speed controller AS3001F-06 AS3001F-08
Silencer
AN101-01
Tubing bore x Length T0604 x 1 m T1075 x 1 m
SY7120-02 Speed controller AS3001F-06 AS4001F-10
Silencer
AN110-01
Tubing bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
SY9120-03 Speed controller AS3001F-06 AS4001F-10 AS4001F-12
Silencer
AN200-02
AN202-02
Conditions
Base mounted
Series CJ2 Series CM2 Series MB, CA2 Series CS1
Tubing bore x Length
T0604 x 1 m
SY3140-01 Speed controller
AS3001F-06
Silencer
AN110-01
Tubing bore x Length T0604 x 1 m T0806 x 1 m
SY5140-02 Speed controller AS3001F-06 AS3001F-08
Silencer
AN101-01
Tubing bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m –
SY7140-03 Speed controller AS3001F-06 AS4001F-10
Silencer
AN200-02
Tubing bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
SY9140-04 Speed controller
AS3001F-06 AS4001F-10 AS4001F-12
Silencer
AN200-02
Conditions [When using SGP (steel pipe)]
Body ported
Tubing bore x Length
SY9120-03 Speed controller
Silencer
Series CS1
SGP10A x 1 m
AS420-03
AN200-02
102
Conditions [When using SGP (steel pipe)]
Base mounted
Tubing bore x Length
SY7140-03 Speed controller
Silencer
Tubing bore x Length
SY9140-04 Speed controller
Silencer
Series CS1
SGP10A x 1 m
AS420-03
AN300-03
SGP15A x 1 m
AS420-04
AN400-04


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Valve Variations
Actuation
Voltage
Note 1)
Electrical entry
P.108
P.126
PE
Series
2 position 3 position DC AC
Sonic
conductance
C [dm3/(s·bar)]
{ }4/25/3
(A/BEA/EB)
24 V 100 V
50/60 Hz
12 V 110 V
6V
50/60 Hz
200 V
5 V 50/60 Hz
3V
220 V
50/60 Hz
SY3 20
SY5 20
0.65
2.4
SY7 20
3.3
SY9 20
8.6
SY3 40
1.1
SY5 40
2.8
SY7 40
4.5
SY9 40
10
Note 4)
Manual
override
P, EA, EB
port size
A, B port size
Valve option
Series
One-touch fitting
M5 1 8 1 4 38 1 2 M5 1 8 1 4 38 1 2
C4 C6 C8 C10 C12 N3 N7 N9 N11
Note 3)
SY3 20
SY5 20
SY7 20
SY9 20
(EA, EB) (P)
SY3 40
SY5 40
SY7 40
SY9 40
Standard Option Made to order (Refer to page “Made to Order”.)
Note 1) All AC voltage models have built-in surge voltage suppressor.
Note 2) Body ported external pilot style (made to order) is not available for DIN terminal.
Note 3) Only available for DIN terminal and M8 connector.
Note 4) SY3000 does not have a DIN terminal which can be connected to a manifold.
External External External DIN
Pilot Pilot Pilot terminal
(Note 2) (Note 2) (Note 2) M8
connector
Sub-plate
External External External DIN
pilot pilot pilot terminal
M8
connector
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
103


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Manifold Variations
Manifold Variations
Valve
Series
5 port
Bar stock type
Individual wiring
í Direct piping to the main unit of
a valve. Combination of
different fittings is possible.
–+
–+
–+
–+
EB
P
EA
Bar stock type
Flat ribbon cable
í A 26 pins MIL connector
permits One-touch wiring of
external cables in a bundle.
EB
P
EA
Stacking type
Individual wiring
–+
–+
–+
–+
í Manifold stations can be increased or decreased.
EB
P
EA
Stacking type
Flat ribbon cable
–+
–+
–+
–+
í Manifold stations can be increased or decreased.
EB
P
EA
Bar stock type
EX510 gateway system
í Can be used with a serial
transmission system.
Stacking type
EX510 gateway system
í Can be used with a serial
transmission system.
Cassette type
Individual wiring
í Size and weight reduced by
eliminating the manifold base
6
7
14
0
15
1
8
9
PWR
COM
EB
P
EA
6
7
14
0
15
1
8
9
PWR
COM
–+
–+
P
20Type
P. 144
20PType
P. 154
23Type
P. 150
23PType
P. 160
20SAType
P. 164
23SAType
P. 170
60Type
P. 178
SY320
SY520
SY720
SY320
SY520
SY720
SY920
SY920
SY320
SY520
SY720
SY920
SY360
SY560
SY760
Standard Option Made to order (Refer to page “Made to Order”.)
Wiring
Connection
Common specifications
In common
In common
104


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Manifold Variations
Manifold option
A, B port size
M5 1 8 1 4 3 8
One-touch fitting
C4 C6 C8 C10 C12 N3 N7 N9 N11 SY3000
SY5000
Valve option
Individual
SUP
interface
Individual
EXH
interface
Individual
SUP
interface
Individual
EXH
interface
Individual
External External SUP External Individual
pilot pilot block disk pilot EXH
Individual
External External
pilot pilot
SUP
block
disk
External
pilot
Individual
EXH
Individual
SUP
interface
Individual
EXH
interface
Individual
External External SUP External Individual
pilot pilot block disk pilot EXH
External External Individual SUP Individual SUP
pilot pilot block disk block disk
External External Individual SUP Individual SUP
pilot pilot block disk block disk
External External Individual SUP Individual SUP
pilot pilot block disk block disk
Note) When using DIN terminal or M8 connector. SY3000 does not have a DIN terminal which can be connected to a manifold.
Note)
SJ
Note)
SYNote)
SV
SYJ
SZ
Note)
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
Note)
SQNote)
VFSNote)
VFR
VQ7
105


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Manifold Variations
Manifold Variations
Valve
Series
5 port
Compact bar stock type
Individual wiring
–+
–+
í The base mounting facilitates maintenance
–+
–+
after valves are changed.
Compact bar stock type
Flat ribbon cable
í A 26 pins MIL connector permits one-touch
wiring of external cables in a bundle.
Bar stock type/Common external EXH
Individual wiring
í The base mounting facilitates
maintenance after valves are changed.
í Vacuum/low pressure combination
system is possible.
–+
–+
–+
–+
Bar stock type/Common external EXH
Flat ribbon cable
í A 26 pins MIL connector permits one-touch
wiring of external cables in a bundle.
í Vacuum/low pressure combination system
is possible.
Stacking type
Individual wiring
–+
–+
–+
–+
í Manifold stations can be increased or decreased.
41Type
P. 198EB
EA P
41PType
P. 214EA
EB P
42Type
P. 198
EB
EA P
42PType
P. 214
EA
EB P
43Type
P. 208
SY340
SY540
SY340
SY540
SY340
SY540
SY740
SY340
SY540
SY740
SY940
Stacking type
Flat ribbon cable
í Manifold stations can be increased or decreased.
43PType
P. 222
SY940
Bar stock type
EX510 gateway system
í Can be used with a serial
transmission system.
6
7
14
0
15
1
8
9
PWR
COM
X
EA P
PEEB
Stacking type
EX510 gateway system
í Can be used with a serial
transmission system.
6
7
14
0
15
1
8
9
PWR
COM
Stacking type/DIN rail mounted
Individual wiring
í Stations can be increased on the DIN rail. Integral
mounting of other electric parts is possible, too.
–+
–+
–+
–+
–+
Stacking type/DIN rail mounted
Connector box
í Stations can be increased or decreased on the DIN rail. The provided
connector box permits one-touch connection of electric cables.
Stacking type/DIN rail mounted
EX510 gateway system
í Can be used with a serial
transmission system.
67
14 15
0
1
89
PWRCOM
Stacking type/DIN rail mounted
Plug-in
í Stations can be increased or decreased on the DIN rail.
í A variety of centralized wiring methods are possible.
Stacking type/DIN rail mounted
Plug-in
EX510 gateway system
í Can be used with a serial transmission system.
42SAType
P. 228
43SAType
P. 233
45Type
P. 244
45-A
Type NA
P. 256
Type45S6A
P. 264
45Type
P. 272
Type45S6B
P. 312
SY340
SY540
SY740
SY940
SY340
SY540
SY340
SY540
SY340
SY540
SY340
SY540
SY340
SY540
Standard Option Made to order (Refer to page “Made to Order”.)
Wiring
Connection
Common specifications
In common
In common
In common
106


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Manifold Variations
Manifold option
A, B port size
M5 1 8 1 4 3 8
One-touch fitting
C4 C6 C8 C10 C12 N3 N7 N9 N11 SY3000
SY5000
Valve option
Individual
SUP
interface
Individual
SUP
interface
External External Individual External
pilot pilot SUP pilot
interface
External External Individual External
pilot pilot SUP pilot
interface
Individual
External
pilot
External
pilot
SUP
block disk
External
pilot
Individual
EXH
Individual
SUP
External External block disk External Individual
pilot pilot
pilot EXH
External External Individual External
pilot pilot SUP pilot
External External Individual External Individual
pilot pilot SUP pilot EXH
Individual
SUP
External
pilot
External
pilot
spacer or
block disk
Individual
SUP
External
External
spacer or
block disk
pilot pilot
Individual
SUP
External
External
spacer or
block disk
pilot pilot
Individual
SUP
External
External
spacer or
block disk
pilot pilot
Individual
SUP
External
External
spacer or
block disk
pilot pilot
Note) When using DIN terminal or M8 connector. SY3000 does not have a DIN terminal which can be connected to a manifold.
Note)
SJ
Note)
SY
SV
Note)
SYJ
Note)
SZ
Note)
VP4
S0700
VQ
Note)
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
Note)
VQ7
Note)
107


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

5 Port Solenoid Valve
Body Ported/Single Unit
Series SY3000/5000/7000/9000
How to Order
SY 5 1 20
Series
3 SY3000
5 SY5000
7 SY7000
9 SY9000
5L
Type of actuation
2 position single
1
2 position double
2
3 position closed center
3
3 position exhaust center
4
3 position pressure center
5
Coil specifications
Nil Standard
With power saving circuit
T (24, 12 VDC only)
Power saving circuit is not
available in the case of D,
DO or W„ type.
For DC
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC Rated voltage
For AC (50 60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
DC specifications of type D, Y, DO and YO
is only available with 12 and 24 VDC.
For type W„, DC voltage is only
available.
Electrical entry
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC
Grommet L plug connector M plug connector
24, 12 VDC/
100, 110, 200, 220 VAC
DIN terminal
G: Lead wire
L: With lead wire
M: With lead wire MN: Without lead wire D, Y: With connector
length 300 mm
(Length 300 mm) (Length 300 mm)
+- +-
+ -+
H: Lead wire
LN: Without lead wire LO: Without connector MO: Without connector DO, YO: Without
length 600 mm
connector
01
Bracket
A, B port size
Thread piping
Symbol
Port size
Applicable series
M5 M5 x 0.8
SY3000
01 1 8
02 1 4
02 1 4
03 3 8
SY5000
SY7000
SY9000
One-touch fitting (Metric size)
Nil: Without bracket
F1: With foot bracket
2 position
single only
F2: With side bracket
Symbol
Port size
Applicable series
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
SY3000
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
C8 One-touch fitting for ø8
C8 One-touch fitting for ø8
C10 One-touch fitting for ø10
C8 One-touch fitting for ø8
C10 One-touch fitting for ø10
C12 One-touch fitting for ø12
SY5000
SY7000
SY9000
SY9000 has no bracket.
Thread type
Nil Rc
FG
One-touch fitting (Inch size)
N NPT
Symbol
Port size
Applicable series T NPTF
N3 One-touch fitting for ø 5 32"
N7 One-touch fitting for ø 1 4"
SY3000
Except for M5
Made to Order
N3 One-touch fitting for ø 5 32"
Nil
N7 One-touch fitting for ø 1 4" SY5000 X20 Body ported external pilot (Refer to page 332.)
N9 One-touch fitting for ø 5 16"
X90 Main valve fluoro rubber (Refer to page 332.)
N9 One-touch fitting for ø 5 16"
N11 One-touch fitting for ø 3 8"
N9 One-touch fitting for ø 5 16"
N11 One-touch fitting for ø 3 8"
SY7000
SY9000
CE-compliant
Nil
Q CE-compliant
For DC only except DIN
Manual override
terminal.
Nil: Non-locking
push type
D: Push-turn locking
slotted type
E: Push-turn locking
lever type
+
-+
24, 12, 6, 5, 3 VDC
M8 connector
WO: Without connector cable
W„: With connector cable
Note)
108
LN, MN type: with 2 sockets.
For DIN terminal of SY3000 series, refer
to page 337.
“Y” type is a DIN terminal conforming to
EN-175301-803C (former DIN43650C).
For details, refer to page 336.
For connector cable of M8 connector,
refer to page 339.
M8 connector conforming to IEC60947-
5-2 standard is also available. Refer to
page 331 for details.
Refer to page 336 for the lead wire
length of L and M plug connectors.
Refer to page 337 for the connector
assembly with cover for L and M plug
connectors.
Note) Enter the cable length symbols in
„. Please be sure to fill in the blank
referring to page 340.
Light/surge voltage suppressor
Electrical entry for G, H, L, M, W
Electrical entry for D, Y
Nil Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
For “R” and “U”, DC voltage is only available.
Power saving circuit is only available in the "Z" type.
Nil Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
DOZ and YOZ are not
available.
For AC voltage valves
there is no “S” option. It is
already built-in to the
rectifier circuit.
Note) When placing an order for body ported solenoid valve as a single unit,
mounting screw for manifold and gasket are not attached. Order them
separately, if necessary. (For details, refer to page 173.)


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Specifications
Made to Order
(For details, refer to pages 324 to 332.)
Response Time
Series
SY3000 SY5000 SY7000 SY9000
Fluid
Air
Internal pilot
2 position single
Operating pressure 2 position double
range (MPa)
3 position
0.15 to 0.7
0.1 to 0.7
0.2 to 0.7
Ambient and fluid temperature (°C)
–10 to 50 (No freezing.)
Max. operating 2 position single, double
10
5
5
5
frequency (Hz) 3 position
333 3
Manual override (Manual operation)
Non-locking push type,
Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust method
Common exhaust type for main and pilot valve
Lubrication
Not required
Mounting orientation
Impact/Vibration resistance (m/s2) Note)
Unrestricted
150/30
Enclosure
Dust proof (DIN terminal and M8 connector: IP65)
Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the
right angles to the main valve and armature in both energized and de-
energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz.
Test was performed at both energized and de-energized states in the axial
direction and at the right angles to the main valve and armature. (Values at
the initial period)
Solenoid Specifications
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
Electrical entry
Grommet (G), (H)
L plug connector (L)
M plug connector (M)
DIN terminal (D), (Y)
M8 connector (W)
G, H, L, M, W
D, Y
Coil rated
DC
24, 12, 6, 5, 3
24, 12
voltage (V)
AC 50 60 Hz
Allowable voltage fluctuation
100, 110, 200, 220
±10% of rated voltage
Power
consumption (W)
DC
Standard
0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
With power saving circuit
0.1 (With indicator light only)
100 V
0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
Apparent power
(VA)
AC
110 V
[115 V]
200 V
0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
[0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)
220 V
[230 V]
1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
[1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
Surge voltage suppressor
Diode (Varistor is for DIN terminal and Non-polar type.)
Indicator light
LED (AC of DIN connector is neon light.)
In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
S, Z and T type (with power saving circuit) should be used within the following allowable voltage
fluctuation range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%
12 VDC: –4% to +10%
T type: 24 VDC: –8% to +10%
12 VDC: –6% to +10%
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage)
SY3000
Type of
actuation
Response time (ms) (at the pressure of 0.5 MPa)
Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z
Type R, U
2 position single
12 or less
15 or less
12 or less
2 position double
10 or less
13 or less
10 or less
3 position
15 or less
20 or less
16 or less
SY5000
Type of
actuation
Response time (ms) (at the pressure of 0.5 MPa)
Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z
Type R, U
2 position single
19 or less
26 or less
19 or less
2 position double
18 or less
22 or less
18 or less
3 position
32 or less
38 or less
32 or less
SY7000
Type of
actuation
Response time (ms) (at the pressure of 0.5 MPa)
Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z
Type R, U
2 position single
31 or less
38 or less
33 or less
2 position double
27 or less
30 or less
28 or less
3 position
50 or less
56 or less
50 or less
SY9000
Type of
actuation
Response time (ms) (at the pressure of 0.5 MPa)
Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z
Type R, U
2 position single
35 or less
41 or less
35 or less
2 position double
35 or less
41 or less
35 or less
3 position
62 or less
64 or less
62 or less
109


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Flow Characteristics/Mass
Series SY3000
Port size
Flow characteristics
Mass (g)
Valve
model
Type of
actuation
1, 5, 3
(P, EA, EB)
4,
(A,
2
B)
1Ǟ4/2 (PǞA/B)
C (kdm3/
(s·bar))
b
Cv
4/2Ǟ5/3 (A/BǞEA/EB)
C (kdm3/
(s·bar) )
b
Cv
Gro-
mmet
L/M
plug
connector
W
M8
connector
2 Single
position Double
0.61
0.44 0.16 0.64 0.45
0.18
51
68
53
74
57
82
Closed
SY3„20 center
-„-M5 3 Exhaust
position center
0.48 0.46 0.13 0.47 0.43 0.13
M5 x 0.8
0.47
0.42
0.13
0.47
(0.44)
0.41
(0.37)
0.13
(0.12)
71
76
84
Pressure
center
0.50
(0.41)
0.48
(0.35)
0.15
(0.11)
0.47
0.43
0.13
2 Single
position Double
0.72
0.29 0.18 0.64 0.34
0.17
60
78
63
83
67
91
Closed
SY3„20 center
-„-C4 3 Exhaust
position center
M5 x 0.8
C4
One-
touch fitting
for ø4
0.59
0.63
0.28 0.15 0.59 0.30
0.35
0.16
0.42
(0.41)
0.34
(0.37)
0.15
0.11
(0.11)
81
86
94
Pressure
center
0.76
(0.46)
0.42
(0.34)
0.21
(0.12)
0.59
0.29
0.15
2 Single
position Double
0.76
0.30 0.19 0.65 0.39
0.17
56
74
59
79
63
87
Closed
SY3„20 center
-„-C6 3 Exhaust
position center
Pressure
center
C6 0.76 0.55 0.24 0.60 0.33 0.16
One-
touch fitting 0.65
for ø6
0.32
0.16
0.64
(0.42)
0.31
(0.36)
0.17
(0.11)
77
82
90
0.77
(0.49)
0.34
(0.43)
0.21
(0.15)
0.61
0.34
0.16
Note) [ ]: denotes normal position.
Series SY7000
Port size
Flow characteristics
Mass (g)
Valve
model
Type of
actuation
1, 5, 3
(P, EA, EB)
4, 2
(A, B)
1Ǟ4/2 (PǞA/B)
C (dm3/
(s·bar) )
b
Cv
4/2Ǟ5/3 (A/BǞEA/EB)
C (dm3/
(s·bar) )
b
Cv
Gro-
mmet
L/M
plug
connector
W
DIN M8
terminal connector
2 Single
position Double
4.1
0.23 0.93
3.3
0.33
0.81
101
120
104
125
125
167
108
133
Closed
SY7„20 center
-„-02 3 Exhaust
position center
2.9 0.31 0.70 2.4 0.38 0.63
14
2.5
0.39 0.65
3.4
(2.1)
0.35
(0.38)
0.82
(0.54)
128
133
175
141
Pressure
center
4.3
(2.4)
0.23 0.97
(0.32) (0.61)
2.2
0.39
0.58
2 Single 1 (P)
position Double Port
3.2
0.26 0.77
3.2
0.37
0.82
107
126
110
132
131
174
114
140
SY7„20
-„-C8
Closed
center
3 Exhaust
position center
Pressure
center
14
5, 3
(EA, EB)
port
18
C8
One-
touch fitting
for ø8
2.6
2.4
3.3
(2.4)
0.24 0.63
0.25 0.57
0.28 0.78
(0.22) (0.57)
2.4
2.6
(1.9)
2.2
0.31
0.42
(0.46)
0.34
0.62
0.70
(0.56)
134
0.60
140 182
148
2 Single
position Double
3.8
0.26 0.86
3.2
0.34
0.82
103
122
105
127
126
169
109
135
Closed
SY7„20 center
-„-C10 3 Exhaust
position center
Pressure
center
C10 2.8 0.27 0.67 2.4 0.21 0.59
One-
touch fitting
for ø10
2.5
0.25 0.59
2.7
(2.0)
0.38
(0.38)
0.70
(0.56)
130
135
177
143
3.8
(2.4)
0.25 0.89
(0.31) (0.61)
2.3
0.38
0.61
Note) [ ]: denotes normal position.
Series SY5000
Port size
Flow characteristics
Mass (g)
Valve
model
Type of
actuation
1, 5, 3
(P, EA, EB)
4,
(A,
2
B)
1Ǟ4/2 (PǞA/B)
C (dm3/
(s·bar) )
b
Cv
4/2Ǟ5/3 (A/BǞEA/EB)
C (dm3/
(s·bar) )
b
Cv
Gro-
mmet
L/M
plug
connector
W
DIN M8
terminal connector
2 Single
position Double
1.9
0.35 0.49
2.4
0.39
0.61
70
88
72 93 76
93 135 101
Closed
SY5„20 center
-„-01 3 Exhaust
position center
1.7 0.43 0.45 1.8 0.35 0.46
18
1.5
0.44 0.41
2.5
(1.5)
0.32
(0.43)
0.59
(0.40)
93
98 140 106
Pressure
center
2.2
(0.91)
0.46 0.61
(0.58) (0.28)
1.8
0.38
0.46
2 Single
position Double
0.75
0.43
0.20
0.85
0.64
0.30
94
111
96
117
117
159
100
125
Closed
SY5„20 center
-„-C4 3 Exhaust
position center
C4 0.74 0.40 0.19 0.84 0.57 0.28
One-
touch fitting
for ø4
0.75
0.36
0.19
0.84
(0.84)
0.64
(0.53)
0.30
(0.27)
117
122
164
130
Pressure
2
center
Single
18
position Double
0.78
(0.71)
0.44
(0.37)
0.21
(0.18)
0.84
0.57
0.27
1.5
0.33 0.33
2.0
0.37
0.52
88
106
91
111
112
153
95
119
Closed
SY5„20 center
-„-C6 3 Exhaust
position center
Pressure
center
C6 1.3 0.31 0.33 1.6 0.32 0.39
One-
touch fitting
for ø6
1.3
0.33 0.33
1.8
(1.4)
0.35
(0.37)
0.44
(0.35)
111
116
158
124
1.7
(0.80)
0.31 0.42
(0.47) (0.23)
1.7
0.33
0.44
2 Single
position Double
1.9
0.21 0.45
2.3
0.29 0.57
80
98
82 103 86
103 145 111
Closed
SY5„20 center
-„-C8 3 Exhaust
position center
Pressure
center
C8 1.6 0.29 0.39 1.7 0.38 0.46
One-
touch fitting
for ø8
1.4
0.38 0.39
2.0
(1.5)
0.37
(0.41)
0.52
(0.43)
103
108
150
116
2.2
(1.6)
0.32 0.56
(0.44) (0.44)
1.8
0.41
0.50
Note) [ ]: denotes normal position.
Series SY9000
Port size
Flow characteristics
Mass (g)
Valve
model
Type of
actuation
1, 5, 3
(P, EA, EB)
4, 2
(A, B)
1Ǟ4/2 (PǞA/B)
C (dm3/
(s·bar) )
b
Cv
4/2Ǟ5/3 (A/BǞEA/EB)
C (dm3/
(s·bar) )
b
Cv
Gro-
mmet
L/M
plug
connector
W
DIN M8
terminal connector
2 Single
position Double
7.0 0.33
1.7
7.6 0.35
2.0
241
260
244
266
265
308
248
274
Closed
SY9„20 center
-„-02 3 Exhaust
position center
6.7 0.37 1.7 6.4 0.34 1.6
14
6.4 0.36
1.6
8.3
(4.1)
0.41
(0.27)
2.2
(0.91)
284
290
332
298
Pressure
center
2 Single
position Double
SY9„20
Closed
center
-„-03 3 Exhaust
position center
8.0
(3.2)
0.27 1.8
(0.34) (0.76)
6.5
0.22
1.4
8.0 0.29
1.9
8.0 0.33
2.0
236
255
239
261
260
303
243
269
7.9 0.33 1.9 6.6 0.27 1.6
38
8.0 0.33
1.9
8.7
(8.3)
0.34
(0.40)
2.2
(2.3)
279
285
327
293
Pressure
center
2 Single
position Double
Closed
SY9„20
-„-C8
3
center
Exhaust
14
position center
Pressure
center
2 Single
position Double
Closed
SY9„20 center
-„-C10 3 Exhaust
position center
Pressure
center
2 Single
position Double
Closed
SY9„20 center
-„-C12 3 Exhaust
position center
Pressure
center
8.9
(3.3)
0.34 2.2
(0.40) (0.82)
6.5
0.25
1.5
4.3
0.28 0.96
7.1
0.32
1.7
293 296 317 300
312 318 360 326
C8 4.3 0.31 0.99 6.1 0.28 1.4
One-
touch fitting 4.3
for ø8
0.3
0.99
7.4
(3.8)
0.36
(0.29)
1.9
(0.86)
336
342
384
350
4.4
(3.2)
0.35 1.0
(0.26) (0.71)
2.1
0.41 0.53
6.1 0.28
1.4
7.9 0.33
1.9
279
298
282
304
303
346
286
312
C10 5.9 0.30 1.4 6.5 0.26 1.5
One-
touch fitting 5.8 0.25
for ø10
1.3
8.4
(4.1)
0.33
(0.27)
2.0
(0.93)
322
328
370
336
6.3
(3.2)
0.29 1.5
(0.29) (0.72)
6.4
0.25
1.5
7.0 0.25
1.6
8.6 0.41
2.2
265
284
268
290
289
332
272
298
C12 6.9 0.24 1.6 7.0 0.33 1.7
One-
touch fitting 6.6 0.23
for ø12
1.4
9.4
(4.5)
0.48
(0.32)
2.6
(1.0)
308
314
356
322
7.4
(3.2)
0.25 1.7
(0.34) (0.74)
6.6
0.23
1.5
Note) [ ]: denotes normal position.
110


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Construction
Series SY
JIS Symbol
2 position single
2 position single (A) (B)
42
JIS Symbol
2 position double
51 3
(EA) (P) (EB)
2 position double (A) (B)
42
SJ
SY
SV
SYJ
SZ
VP4
513
(EA) (P) (EB)
S0700
VQ
3 position closed center / exhaust center / pressure center
JIS Symbol
3 position closed center
(A) (B)
42
VQ4
VQ5
VQC
3 position exhaust center
VQZ
SQ
3 position pressure center
513
(EA) (P) (EB)
(This figure shows a closed center type.)
VFS
VFR
Component Parts
No. Description
1 Body
Material
Aluminum die-casted
(SY3000: Zinc die-casted)
2 Adapter plate
Resin
3 End plate
4 Piston
5 Spool valve assembly
Resin
Resin
Aluminum, H-NBR
Note
White
White
(SY9000: Gray)
White
How to Change Port Block Assembly
VQ7
If using body port type, both A and B port sizes can be changed by replacing
the port block assembly mounted on the body. When changing this block
assembly, the correct screw torque must be achieved to avoid possible air
leakage.
For SY5000
M5 port block Assembly
(Cassette type)
M5 port block Assembly
(Threaded style)
Fitting
Assembly
Mounting screw
Replacement Parts
No. Description
Part no.
6 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 112.
7 M5 port block assembly Refer to “How to Order Port Block Assembly” on page 113.
Bracket Assembly No.
Description
Part no.
Bracket (For F1)
Bracket (For F2)
3
SX5000-16-2A (with mounting screw)
7
3
SX5000-16-1A (with mounting screw)
7
SY9000 has no bracket.
Caution
Mounting screw tightening torques
SY3000 (M2): 0.12 N·m
SY
5
7
000
(M3):
0.6
N·m
SY9000 (M4): 1.4 N·m
Refer to “How to Order
Port Block Assembly” on
page 113 for part no.
111


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
How to Order Pilot Valve Assembly
V111 5
Coil specifications
Nil Standard
With power saving circuit
T (24 VDC, 12 VDC only)
Power saving circuit
is not available in
the case of D, DO
or W„ type.
Rated voltage
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
1 100 VAC 50 60Hz
2 200 VAC 50 60Hz
3
110 VAC 50 60Hz
[115 VAC 50 60Hz]
4
220 VAC 50 60Hz
[230 VAC 50 60Hz]
For type W„, DC
voltage is only
available.
CE-compliant: For
DC only.
G
Light/surge voltage suppressor
Nil Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
For AC voltage valves there is no “S” option. It is
already built-in to the rectifier circuit.
For “R” and “U”, DC voltage is only available.
Power saving circuit is only available in the “Z” type.
Electrical entry
G Grommet, 300 mm lead wire
H Grommet, 600 mm lead wire
L
LN
L plug
connector
LO
With lead wire
Without lead wire
Without connector
M
MN
M plug
connector
MO
WO M8
W„ connector
With lead wire
Without lead wire
Without connector
Without connector cable
With connector cable Note 1)
For connector cable of M8 connector,
refer to page 339.
Note 1) Enter the cable length symbols in
„. Please be sure to fill in the blank
referring to page 340.
í DIN terminal type
V115 5 D
Rated voltage
5 24 VDC
6 12 VDC
1 100 VAC 50 60 Hz
2 200 VAC 50 60 Hz
3
110 VAC 50 60 Hz
[115 VAC 50 60 Hz]
4
220 VAC 50 60 Hz
[230 VAC 50 60 Hz]
DC specifications of
type D and DO is
only available with 12
and 24 VDC.
Light/surge voltage suppressor
Nil Without light/surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
Z With light/surge voltage suppressor (Non-polar type)
DOZ and YOZ are not available.
For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
Electrical entry
D DIN
terminal
DO (Type D)
With connector
Without connector
Y DIN
terminal
YO (Type Y)
With connector
Without connector
Note) Do not replace V111
(G, H, L, M) to V115
(DIN terminal) and
vice versa when
replacing pilot valve
assembly only.
Note) Since V111 and V115 are CE-compliant as
standard, the suffix “-Q” is not necessary.
112


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
How to Order Port Block Assembly
SY 000 6A
Series
3 SY3000
5 SY5000
7 SY7000
9 SY9000
A, B port size
Thread piping
Symbol
Port size
Applicable series
M5 M5 x 0.8 SY3000
01 1 8 SY5000
02 1 4 SY7000
02
03
14
38
SY9000
One-touch fitting (Metric size)
Symbol
Port size
Applicable series
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
SY3000
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6 SY5000
C8 One-touch fitting for ø8
C8
C10
One-touch fitting for ø8
One-touch fitting for ø10
SY7000
C8 One-touch fitting for ø8
C10 One-touch fitting for ø10 SY9000
C12 One-touch fitting for ø12
Thread type
Nil Rc
FG
N NPT
T NPTF
Except for M5
One-touch fitting (Inch size)
Symbol
Port size
Applicable series
N3
N7
One-touch fitting for ø 5 32"
One-touch fitting for ø 1 4"
SY3000
N3 One-touch fitting for ø 5 32"
N7 One-touch fitting for ø 1 4" SY5000
N9 One-touch fitting for ø 5 16"
N9
N11
One-touch fitting for ø 5 16"
One-touch fitting for ø 3 8"
SY7000
N9
N11
One-touch fitting for ø 5 16"
One-touch fitting for ø 3 8"
SY9000
Only replacement of the fittings assembly is possible.
Metric size
Inch size
SY3000
One-touch fitting for ø4
One-touch fitting for ø6
VVQ1000-50A-C4
VVQ1000-50A-C6
One-touch fitting for ø4 VVQ1000-51A-C4
SY5000 One-touch fitting for ø6 VVQ1000-51A-C6
One-touch fitting for ø8 VVQ1000-51A-C8
SY7000 One-touch fitting for ø8 VVQ2000-51A-C8
One-touch fitting for ø10 VVQ2000-51A-C10
One-touch fitting for ø8 VVQ4000-50B-C8
SY9000 One-touch fitting for ø10 VVQ4000-50B-C10
One-touch fitting for ø12 VVQ4000-50B-C12
SY3000
One-touch fitting for ø 5 32"
One-touch fitting for ø 1 4"
VVQ1000-50A-N3
VVQ1000-50A-N7
One-touch fitting for ø 5 32" VVQ1000-51A-N3
SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø 5 16" VVQ1000-51A-N9
SY7000
One-touch fitting for ø 5 16"
One-touch fitting for ø 3 8"
VVQ2000-51A-N9
VVQ2000-51A-N11
SY9000
One-touch fitting for ø 5 16"
One-touch fitting for ø 3 8"
VVQ4000-50B-N9
VVQ4000-50B-N11
Mounting
screw
Port block assembly
(Cassette type)
SJ
SY
SV
SYJ
SZ
Fitting assembly
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
113


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Dimensions: Series SY3000
2 position single
Grommet
(G),
(H):
SY3120-„
G
H
„„-
C4,
C6,
N3
N7
(-F2)
2 x M3 x 0.5 depth 3.5
9.5 (For mounting bracket)
Foot bracket
SY3120-„
G
H
„„-
C4,
C6,
N3
N7
-F1
38
31
13.1
[ ]: AC
G: Approx. 300
H: Approx. 600
(Lead wire length)
66.9 [69.1]
44.7
A
Manual override
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
21.4
(35)
2 x ø3.2
(Light/surge voltage suppressor) (For mounting)
(27)
B
10.2
2 x ø2.2
(For manifold mounting)
-+
22.5
28.5 [35.5]
25
2 x ø3.2
(For mounting)
(3.2)
C6:33.6
N7:37.4
7.5
SY3120-„HG„„-M5(-F2)
M5 x 0.8
A, B port
2 x ø1.5 die-cast hole
For manifold gasket positioning
P
EA EB
19
M5 x 0.8
(P, EA, EB port)
L plug connector (L):
SY3120-„L„„-
C4,
C6,
N3
N7
(-F12 )
28.5 [35.5]
13.1
M plug connector (M):
SY3120-„M„„-
C4,
C6,
NN37(-F12
)
(Lead wire length)
Approx.
39.6 [46.6] 300
22.5
M8 connector (WO):
SY3120-„WO„„-
C4,
C6,
N3
N7
(-F
1
2
)
33
15.5
M8 x 1
114
16.9
18.5
C6: 33.6
N7: 37.4
(3.2)
16.9
18.5
C6: 33.6
N7: 37.4
(3.2)
16.9
18.5
C6: 33.6
N7: 37.4
(3.2)
Note) Refer to page 340 for
dimensions of connector types.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Dimensions: Series SY3000
2 position double
Grommet
(G),
(H):
SY3220-„
G
H
„„-
C4,
C6,
N3
N7
(-F2)
2 x M3 x 0.5 depth 3.5
9.5 (For mounting bracket)
SY3220-„HG„„-M5(-F2)
M5 x 0.8
(A, B port)
[ ]: AC
G: Approx. 300
H: Approx. 600
(Lead wire length)
88.8 [93.2]
44.4
A
Manual override
One-touch fitting
A, B port
Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4"
21.4
B
10.2
2 x ø2.2
(For manifold mounting)
(Light/surge voltage suppressor)
(35)
2 x ø3.2
(27) (For mounting)
-+
2 x ø1.5 die-cast hole
(For manifold gasket positioning)
P
EA EB
19
M5 x 0.8
(P, EA, EB port)
L plug connector (L):
SY3220-„L„„-
C4,
C6,
N3
N7
(-F2)
28.5 [35.5]
13.1
M plug connector (M):
SY3220-„M„„-
C4,
C6,
N3
N7
(-F2)
M8 connector (WO):
SY3220-WO„„-
C4,
C6,
N3
N7
(-F
1
2
)
39.6 [46.6]
Approx. 300
(Lead wire length)
33
15.5
M8 x 1
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
16.9
C6:33.6
N7:37.4 (3.2)
16.9
C6:33.6
N7:37.4 (3.2)
16.9
C6:33.6
N7:37.4 (3.2)
Note) Refer to page 340 for
dimensions of connector types.
115


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Dimensions: Series SY3000
3 position closed center / exhaust center / pressure center
Grommet
(G),
(H):
SY3
3
4
5
20-„GH„„-
C4,
C6,
N3
N7
(-F2)
2 x M3 x 0.5 depth 3.5
9.5 (For mounting bracket)
SY3
3
4
5
20-„
G
H
„„-M5(-F2)
M5 x 0.8
(A, B port)
[ ]: AC
G: Approx. 300
H: Approx. 600
(Lead wire length)
97.3 [101.7]
44.4 [46.6]
22.2 30.7
A
Manual override
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4"
(Light/surge voltage suppressor)
21.4
(35)
(27)
B
10.2
2 x ø2.2
(For manifold mounting)
2- ø3.2
(For mounting)
-+
2 x ø1.5 die-cast hole
For manifold gasket positioning
P
EA
19 M5 x 0.8
(P, EA, EB port)
L plug connector (L):
SY3
3
4
5
20-„L„„-
C4,
C6,
N3
N7
(-F2)
28.5 [35.5]
13.1
M plug connector (M):
3
SY345
20-„M„„-
C4,
C6,
N3
N7
(-F2)
M8 connector (WO):
SY3
3
4
5
20-„WO„„-
C4,
C6,
N3
N7
(-F2)
39.6 [46.6]
Approx. 300
(Lead wire length)
33
15.5
M8 x 1
116
16.9
C6: 33.6
N7: 37.4
(3.2)
16.9
C6: 33.6
N7: 37.4
(3.2)
16.9
C6: 33.6
N7: 37.4
(3.2)
Note) Refer to page 340 for
dimensions of connector types.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Dimensions: Series SY5000
2 position single
Grommet
(G),
(H):
SY5120-„GH„„-
C4,
C6,
C8,
N3
N7
„(-F2)
N9
22.6
2 x M3 x 0.5 depth 3.5
(For mounting bracket)
[ ]: AC
Foot bracket
SY5120-„
G
H
„„-
C4,
C6,
C8,
N3
N7
N9
„-F1
47
38
12.7
G: Approx. 300
H: Approx. 600
(Lead wire length)
85.9 [88.1]
63.7
One-touch fitting
A, B port
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
28.1 [35.1]
2 x ø3.2
(For mounting)
SJ
SY
SV
SYJ
Manual override
A
(Light/surge voltage suppressor)
14.5
36
(45)
(37)
B
2 x ø3.2
(For manifold mounting)
(For
mounting)
2 x ø3.2
(4.9)
40.4
10.5
SZ
VP4
S0700
VQ
VQ4
-+
SY5120-„
G
H
„„-01„(-F
1
2
)
VQ5
32.3
EA P
EB
27.2 1/8
(P, EA, EB port)
2 x ø2.2 die-cast hole
For manifold gasket positioning
1/8
16.2 (A, B port)
VQC
VQZ
SQ
VFS
L plug connector (L):
SY5120-„L„„-CC46,,
N3
N7
„(-F12
)
C8, N9
M plug connector (M):
SY5120-„M„„-CC46,,
N3
N7
„(-F
12)
C8, N9
VFR
DIN terminal (D, Y):
M8 connector (WO):
SY5120-„DY „„-
C4,
C6,
N3
N7
„(-F12
)
SY5120-„WO„„-
C4,
C6,
N3
N7
„(-F
1
2
)
VQ7
C8, N9
C8, N9
28.1 [35.1]
12.7
39.2 [46.2]
Approx. 300
(Lead wire length)
60.9
53.4
42.1
27
Applicable cable O.D.
ø3.5 to ø7
32.6
15.1
M8 x 1
Pg7
20.5
23
40.4
(4.9)
20.5
23
40.4
(4.9)
20.5
23
40.4
(4.9)
20.5
23
40.4
(4.9)
Note) Refer to page 340 for
dimensions of connector types.
117


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Dimensions: Series SY5000
2 position double
Grommet
(G),
(H):
SY5220-„
G
H
„„-
C4,
C6,
C8,
N3
NN79„(-F2)
22.6
2 x M3 x 0.5 depth 3.5
(For mounting bracket)
[ ]: AC
SY5220-„GH„„-01„(-F2)
16.2 1/8
(A, B port)
G: Approx. 300
H: Approx. 600
(Lead wire length)
107.2 [111.6]
62.8
One-touch fitting
(A, B port)
Applicable tubing O.D. : ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
Manual override
A
(Light/surge voltage suppressor)
14.5
36
(45)
(37)
B
2 x ø3.2
(For manifold mounting)
2 x ø3.2
(For mounting)
-+
EA P
EB
27.2 1/8
2 x ø2.2 die-cast hole (P, EA, EB port)
For manifold gasket positioning
L plug connector (L):
M plug connector (M):
DIN terminal (D, Y):
M8 connector (WO):
SY5220-„L„„-
C4,
C6,
N3
N7
„(-F2)
C8, N9
SY5220-„M„„-
C4,
C6,
N3
N7
„(-F2)
C8, N9
SY5220-„DY„„-
C4,
C6,
C8,
NN37„(-F2)
N9
SY5220-„WO„„-
C4,
C6,
N3
N7
„(-F2)
C8, N9
28.1 [35.1]
12.7
39.2 [46.2]
Approx. 300
(Lead wire length)
60.9
53.4
42.1
27
Applicable cable O.D.
ø3.5 to ø7
32.6 M8 x 1
15.1
Pg7
20.5
40.4
(4.9)
118
20.5
40.4
(4.9)
20.5
40.4
(4.9)
20.5
40.4
(4.9)
Note) Refer to page 340 for
dimensions of connector types.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Dimensions: Series SY5000
3 position closed center / exhaust center / pressure center
Grommet
(G),
(H):
3
SY5 4 20-„
5
GH „„-
C4,
C6,
C8,
NN37 „(-F2)
N9
22.6
2 x M3 x 0.5 depth 3.5
(For mounting bracket)
33
SY5 420-„ 4 „„-01„(-F2)
55
1/8
16.2
(A, B port)
[ ]: AC
G: Approx. 300
H: Approx. 600
(Lead wire length)
119.8 [124.2]
53.6 [55.8]
31.4 44
One-touch fitting
(A, B port)
Applicable tubing O.D.:
ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
SJ
SY
SV
SYJ
Manual override
(Light/surge voltage suppressor)
14.5
36
(45)
(37)
2 x ø3.2
(For manifold mounting)
2 x ø3.2
(For mounting)
SZ
VP4
S0700
VQ
VQ4
-+
VQ5
VQC
2 x ø2.2 die-cast hole
For manifold gasket positioning
27.2 1/8
(P, EA, EB port)
VQZ
SQ
VFS
VFR
L plug connector (L): M plug connector (M): DIN terminal (D, Y):
M8 connector (WO):
SY5
3
420-„L„„-
5
C4,
C6,
C8,
N3
N7
N9
„(-F2)
SY5
3
420-„M„„-
5
C4,
C6,
C8,
N3
N7
N9
„(-F2)
SY5
345 20-„DY „„-
C4,
C6,
C8,
N3
N7
N9
„(-F2)
SY5
34520-„WO„„-CCC468,,,
N3
N7
N9
„(-F2)
VQ7
28.1 [35.1]
12.7
39.2 [46.2]
Approx. 300
(Lead wire length)
60.9
53.4
42.1
27
Applicable cable O.D.
ø3.5 to ø7
32.6 M8 x 1
15.1
Pg7
20.5
40.4 (4.9)
20.5
40.4 (4.9)
20.5
40.4 (4.9)
20.5
40.4 (4.9)
Note) Refer to page 340 for
dimensions of connector types.
119


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Dimensions: Series SY7000
2 position single
Grommet
(G),
(H):
SY7120-„GH„„-
C8, N9
C10, N11
„(-F2)
2 x M4 x 0.7 depth 6.5
20 (For mounting bracket)
[ ]: AC
SY7120-„GH„- CC180,,NN911„-F1
57
46
16.1
G: Approx. 300
H: Approx. 600
(Lead wire length)
100.1 [102.3]
77.9
One-touch fitting
(A, B port)
Applicable tubing O.D. : ø8, ø5/16"
: ø10, ø3/8"
Manual override
(Light/surge voltage suppressor)
A
19
42
B
2 x ø4.2
(For manifold mounting)
(66) (For mounting)
(52) 2 x ø4.2
2 x ø4.2
(For mounting)
31.5 [38.5]
-+
2 x ø2.2 die-cast hole
For manifold gasket positioning
39.4
1/4
(P port)
EA P
36
EB
1/8
(EA, EB port)
(5.5) 47.6 12.5
SY7120-„GH„„-02„(-F2)
1/4
20 A, B port
39.4
L plug connector (L):
M plug connector (M): DIN terminal (D, Y):
M8 connector (WO):
SY7120-„L„„-CC180,,NN911„(-F12) SY7120-„M„„-CC180,,NN911„(-F 12) SY7120-„DY„„-CC180,,NN911„(-F12 ) SY7120-„WO„„-CC180,,NN911„(-F12)
31.5 [38.5]
16.1
42.6 [49.6]
Approx. 300
(Lead wire length)
66
58.5
47.2
32.1
Applicable cable O.D.
ø3.5 to ø7
36
19
M8 x1
Pg7
24.5
28
47.6
(5.5)
24.5
28
47.6
(5.5)
120
24.5
28
47.6
(5.5)
24.5
28
47.6
(5.5)
Note) Refer to page 340 for
dimensions of connector types.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Dimensions: Series SY7000
2 position double
Grommet (G), (H): SY7220-„GH„„-CC180,,NN911„(-F2)
2 x M4 x 0.7 depth 6.5
20 (For mounting bracket)
[ ]: AC
SY7220-„GH„„-02„(-F2)
1/4
20 (A, B port)
SJ
G: Approx. 300
H: Approx. 600
(Lead wire length)
Manual override
(Light/surge voltage suppressor)
121.4 [125.8]
77
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø8, ø5/16"
ø10, ø3/8"
B
A
19 2 x ø4.2
42
(66)
(For manifold mounting)
(For mounting)
2 x ø4.2
(52)
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
-+
VQ5
2 x ø2.2 die-cast hole
For manifold gasket positioning
1/4
(P port)
EA P
36
EB
1/8
(EA, EB port)
VQC
VQZ
SQ
VFS
VFR
L plug connector (L):
SY7220-„L„„-CC180,,NN911„(-F2)
M plug connector (M):
SY7220-„M„„- CC180,,NN911„(-F2)
DIN terminal (D, Y):
SY7220-„DY „„- CC180,,NN911„(-F2)
M8 connector (WO):
SY7220-„WO„„-CC180,,NN911„(-F2)
VQ7
31.5 [38.5]
16.1
42.6 [49.6] Approx. 300
(Lead wire length)
66
58.5
47.2
32.1
Applicable cable O.D.
ø3.5 to ø7
36
18.5 M8 x 1
Pg7
24.5
47.6
(5.5)
24.5
47.6
(5.5)
24.5
47.6
(5.5)
24.5
47.6
(5.5)
Note) Refer to page 340 for
dimensions of connector types.
121


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Dimensions: Series SY7000
3 position closed center / exhaust center / pressure center
Grommet
(G),
(H):
SY7
3
4
20-„
5
G
H
„„-
CC180,,NN911„(-F2)
2 x M4 x 0.7 depth 6.5
20 (For mounting bracket)
SY7
3
4
5
20-„
G
H
„„-02„(-F2)
1/4
20 (A, B port)
[ ]: AC
G: Approx. 300
H: Approx. 600
(Lead wire length)
One-touch fitting
134.4 [138.8]
(A, B port)
Applicable tubing O.D. : ø8, ø5/16"
: ø10, ø3/8"
60.7 [62.9]
38.5 51.5
B
Manual override
A
19
42
2 x ø4.2
(For manifold mounting)
(Light/surge voltage suppressor)
2 x ø4.2
(66)
(For mounting)
(52)
-+
2 x ø2.2 die-cast hole
For manifold gasket positioning
1/4
(P port)
EA P
36
EB
1/8
(EA, EB port)
L plug connector (L):
M plug connector (M): DIN terminal (D, Y):
M8 connector (WO):
SY7
3
420-„L„„-
5
CC180,,NN911„(-F2)
3
SY74
5
20-„M„„-
CC180,,NN911„(-F2)
3
SY74
5
20-„DY „„-CC180,,NN911„(-F2)
3
SY74
5
20-„WO„„-
CC180,,NN911„(-F2)
31.5 [38.5]
16.1
42.6 [49.6]
Approx. 300
(Lead wire length)
66
58.5
47.2
32.1
Applicable cable O.D.
ø3.5 to ø7
36
18.5 M8 x 1
Pg7
24.5
47.6
(5.5)
122
24.5
47.6 (5.5)
24.5
47.6
(5.5)
24.5
47.6
(5.5)
Note) Refer to page 340 for
dimensions of connector types.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Dimensions: Series SY9000
2 position single
Grommet (G), (H):
SY9120-„
G
H
C8, N9
„„-C10, N11„
C12
G: Approx. 300
H: Approx. 600
130.2 [132.4]
(Lead wire length)
108
Manual 6.5
override
4A
56.3
2B
SY9120-„GH „„-0023„
[ ] AC
3/8, 1/4
[4(A), 2(B) port)]
SJ
One-touch fitting
[4(A), 2(B) port]
Applicable tubing O.D.: ø8, ø5/16"
(Light/surge voltage suppressor)
ø10, ø3/8"
ø12
33.6
64.2
3 x ø3.2
(For manifold mounting)
SY
SV
SYJ
SZ
VP4
-+
S0700
2 x ø4.4
(For mounting)
24.9
1/4
[1(P), 5(EA), 3(EB) port]
36.6
39.1
51.5
VQ
VQ4
VQ5
5EA 1P 3EB
49.8
VQC
VQZ
SQ
L plug connector (L):
SY9120-„L„„-CC81,0N, N911„
C12
M plug connector (M): DIN terminal (D, Y):
M8 connector (WO):
VFS
SY9120-„M„„-CC81,0N, N911„
C12
SY9120-„DY„„-CCC811,02N, N911„
SY9120-„WO„„-CC81,0N, N911„
C12
VFR
40.9 [47.9]
25.5
52 [59]
Approx. 300
(Lead wire length)
74.7
67.2
55.9
40.9
Applicable cable O.D.
ø3.5 to ø7
45.4
27.9
M8 x 1
Pg7
VQ7
36.6
39.1
61
(5.5)
36.6
39.1
61
(5.5)
36.6
39.1
61
(5.5)
36.6
39.1
61
(5.5)
Note) Refer to page 340 for
dimensions of connector types.
123


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Dimensions: Series SY9000
2GrpoomsimtioentG(dG: oA)p,up(rboHxle.):30S0Y9220-„GH„„-CCC811,02N, N911„
H: Approx. 600
147.8 [152.2]
(Lead wire length)
103.4
Manual
override
6.5
4A 2B
[ ] : AC
SY9220-„
G
H
„„-0023„
3/8, 1/4
[4(A), 2(B) port)]
One-touch fitting [4 (A), 2 (B) port]
Applicable tubing O.D.: ø8, ø5/16"
: ø10, ø3/8"
(Light/surge voltage suppressor) : ø12
33.6
64.2
3 x ø3.2
(For manifold mounting)
-+
2 x ø4.4
(For mounting)
24.9
1/4
[1(P), 5(EA), 3(EB) port]
5EA 1P 3EB
49.8
36.6
51.5
L plug connector (L):
M plug connector (M): DIN terminal (D, Y):
SY9220-„L„„-CC81,0N, N911„
C12
SY9220-„M„„-CC81,0N, N911„
C12
SY9220-„DY„„-CCC811,02N, N911„
M8 connector (WO):
SY9220-„WO„„-CC81,0N, N911„
C12
40.9 [47.9]
25.5
52 [59]
Approx. 300
(Lead wire length)
74.7
67.2
55.9
40.9
Applicable cable O.D.
ø3.5 to ø7
45.4
27.9
M8 x 1
Pg7
36.6
61
(5.5)
36.6
61
(5.5)
124
36.6
61
(5.5)
36.6
61
(5.5)
Note) Refer to page 340 for
dimensions of connector types.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Body Ported Series SY3000/5000/7000/9000
Dimensions: Series SY9000
3 position closed center / exhaust center / pressure center
Grommet (G), (H):
G: Approx. 300
SY9 34520-„GH
„„-
C8, N9
C10, N11„
C12
H: Approx. 600
164.3 [168.7]
(Lead wire length)
73.9 [76.1]
51.7 68.2
Manual 6.5
override
4A 2B
One-touch fitting [4 (A), 2 (B) port]
Applicable tubing O.D. : ø8, ø5/16"
: ø10, ø3/8"
: ø12
33.6
64.2
3 x ø3.2
(For manifold mounting)
[ ]: AC
SY9
3
420-„
5
G
H
„„-
02
03
„
3/8, 1/4
[4(A), 2(B) port)
SJ
SY
SV
SYJ
SZ
- + VP4
(Light/surge voltage suppressor) 2 x ø4.4
(For mounting)
24.9
1/4
[1(P), 5(EA), 3(EB) port]
5EA 1P 3EB
49.8
L plug connector (L):
3 C8, N9
SY94
5
20-„L„„-C10,
C12
N11„
M plug connector (M):
3 C8, N9
SY94
5
20-„M„„-C10,
C12
N11„
DIN terminal (D, Y):
3
SY94
5
20-„DY
C8, N9
„„-C10, N11„
C12
S0700
VQ
36.6
51.5
VQ4
VQ5
M8 connector (WO):
3 C8, N9
SY94520-„WO„„-CC1102, N11„
VQC
VQZ
SQ
40.9 [47.9]
25.5
52 [59]
Approx. 300
(Lead wire length)
74.7
67.2
55.9
40.9
Applicable cable O.D.
ø3.5 to ø7
45.4
27.9
M8 x 1
Pg7
VFS
VFR
VQ7
36.6
61
(5.5)
36.6
61
(5.5)
36.6
61
(5.5)
36.6
61
(5.5)
Note) Refer to page 340 for
dimensions of connector types.
125


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

5 Port Solenoid Valve
Base Mounted/Single Unit
Series SY3000/5000/7000/9000
How to Order
SY 5 2 40
Series
3 SY3000
5 SY5000
7 SY7000
9 SY9000
Type of actuation
2 position single
1
2 position double
2
3 position closed center
3
5L
Port size
Symbol
Port size
Applicable series
Nil Without sub-plate
01
18
With sub-plate
SY3000
02
14
With sub-plate
03
38
With sub-plate
04
12
With sub-plate
SY5000
SY7000
SY7000
SY9000
SY9000
Thread type
Nil Rc
FG
N NPT
T NPTF
Made to Order
Nil
X90
Main valve fluoro rubber
(Refer to page 332.)
Manual override
CE-compliant
Nil
Nil: Non-locking D: Push-turn locking E: Push-turn locking Q CE-compliant
push type
slotted type
lever type
For DC only
except DIN
terminal.
3 position exhaust center
4
3 position pressure center
5
Pilot type
Nil Internal pilot
R External pilot
Coil specifications
Nil Standard
T With power saving circuit (24, 12 VDC only)
Power saving circuit is not available in
the case of D, Y, DO, YO or W„ type.
Rated voltage
For DC
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
For AC (50 60 Hz)
R 3 VDC
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
DC specifications of type D, Y, DO and YO
is only available with 12 and 24 VDC.
For type W„, DC voltage is only available.
126
Light/surge voltage suppressor
Electrical entry for G, H, L, M, W
Electrical entry for D, Y
Nil Without light/surge voltage suppressor
Nil Without light/surge voltage suppressor
S With surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
Z With light/surge voltage suppressor
Z With light/surge voltage suppressor (Non-polar type)
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
For “R” and “U”, DC voltage is only available.
Power saving circuit is only available in the "Z" type.
DOZ and YOZ are not available.
For AC voltage valves there is no “S”
option. It is already built-in to the
rectifier circuit.
Electrical entry
24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC
Grommet L plug connector
M plug connector
24, 12 VDC/
100, 110, 200, 220 VAC
24, 12, 6, 5, 3 VDC
DIN terminal
M8 connector
G: Lead wire
L: With lead wire M: With lead wire MN: Without lead (Except SY3000)
length 300 mm (Length 300 mm) (Length 300 mm)
wire
D, Y: With connector
WO: Without connector cable
+-
+-
–+ - +
H: Lead wire
LN: Without
length 600 mm
lead wire
LO: Without
connector
MO: Without DO, YO: Without connector W„: With connector cable
connector
Note)
–+ - +
LN, MN type: with 2 sockets.
For DIN terminal of SY3000 series, refer to page 337.
“Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). For details, refer
to page 336.
For connector cable of M8 connector, refer to page 339.
M8 connector conforming to IEC60947-5-2 standard is also available. Refer to page 331 for details.
Refer to page 336 for the lead wire length of L and M plug connectors.
Refer to page 337 for the connector assembly with cover for L and M plug connectors.
Note) Enter the cable length symbols in „. Please be sure to fill in the blank referring to page 340.


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Base Mounted Series SY3000/5000/7000/9000
Specifications
Made to Order
(For details, refer to pages 324 to 332.)
Response Time
Note) Based on dynamic performance
test, JIS B 8375-1981. (Coil
temperature: 20°C, at rated voltage)
SY3000
Response time (ms)
Type of
(at the pressure of 0.5 MPa)
actuation Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z Type R, U
2 position single 12 or less 15 or less 12 or less
2 position double 10 or less 13 or less 10 or less
3 position 15 or less 20 or less 16 or less
SY5000
Response time (ms)
Type of
(at the pressure of 0.5 MPa)
actuation Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z Type R, U
2 position single 19 or less 26 or less 19 or less
2 position double 18 or less 22 or less 18 or less
3 position 32 or less 38 or less 32 or less
SY7000
Response time (ms)
Type of
(at the pressure of 0.5 MPa)
actuation Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z Type R, U
2 position single 31 or less 38 or less 33 or less
2 position double 27 or less 30 or less 28 or less
3 position 50 or less 56 or less 50 or less
SY9000
Response time (ms)
Type of
(at the pressure of 0.5 MPa)
actuation Without light/surge With light/surge voltage suppressor
voltage suppressor Type S, Z Type R, U
2 position single 35 or less 41 or less 35 or less
2 position double 35 or less 41 or less 35 or less
3 position 62 or less 64 or less 62 or less
Series
Fluid
Internal pilot
2 position single
Operating pressure 2 position double
range (MPa)
3 position
Operating pressure range
External pilot
Operating pressure
range (MPa)
Pilot 2 position single
pressure 2 position double
range 3 position
SY3000
SY5000 SY7000
Air
0.15 to 0.7
0.1 to 0.7
0.2 to 0.7
–100 kPa to 0.7
0.25 to 0.7
0.25 to 0.7
0.25 to 0.7
SY9000
Ambient and fluid temperature (°C)
–10 to 50 (No freezing.)
Max. operating 2 position single, double
10
5
5
5
frequency (Hz) 3 position
3333
Manual override
(Manual operation)
Non-locking push type,
Push-turn locking slotted type, Push-turn locking lever type
Pilot exhaust
method
Internal pilot
External pilot
Common exhaust type for main and pilot valve
Pilot valve individual exhaust
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2) Note)
Not required
Unrestricted
150/30
Enclosure
Dust proof (DIN terminal and M8 connector: IP65)
Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles
to the main valve and armature in both energized and de-energized states every
once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at the
right angles to the main valve and armature. (Values at the initial period)
Solenoid Specifications
Electrical entry
Grommet (G), (H)
L plug connector (L)
M plug connector (M)
DIN terminal (D), (Y)
M8 connector (W)
G, H, L, M, W
D, Y
Coil rated
DC
24, 12, 6, 5, 3
24, 12
voltage (V)
AC 50 60 Hz
Allowable voltage fluctuation
100, 110, 200, 220
±10% of rated voltage
Power
consumption (W)
DC
Standard
With power saving circuit
0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
0.1 (With indicator light only)
100 V
0.78 (With indicator light: 0.81) 0.78 (With indicator light: 0.87)
Apparent power
(VA)
AC
Surge voltage suppressor
Indicator light
110 V
[115 V]
200 V
220 V
[230 V]
0.86 (With indicator light: 0.89) 0.86 (With indicator light: 0.97)
[0.94 (With indicator light: 0.97)] [0.94 (With indicator light: 1.07)]
1.18 (With indicator light: 1.22) 1.15 (With indicator light: 1.30)
1.30 (With indicator light: 1.34) 1.27 (With indicator light: 1.46)
[1.42 (With indicator light: 1.46)] [1.39 (With indicator light: 1.60)]
Diode (Varistor is for DIN terminal and Non-polar type.)
LED (AC of DIN connector is neon light.)
In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
S, Z and T type (with power saving circuit) should be used within the following allowable voltage
fluctuation range due to a voltage drop caused by the internal circuit.
S and Z type: 24 VDC: –7% to +10%
12 VDC: –4% to +10%
T type: 24 VDC: –8% to +10%
12 VDC: –6% to +10%
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
127


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
Flow Characteristics/Mass
Series SY3000
Valve model
Type of
actuation
Flow characteristics Note 1)
Port
size
1 4/2 (P A/B)
4/2 5/3 (A/B EA/EB)
C (dm3/(s·bar)) b
Cv C (dm3/(s·bar)) b
Cv
2 Single
position Double
1.0 0.30 0.24 1.1 0.30 0.26
Closed center
0.77 0.28 0.18 0.85 0.30 0.19
SY3„40-„-01
Exhaust
3
position
center
Pressure
center
18
0.73
1.2
[0.51]
0.31
0.24
[0.45]
0.18
0.29
[0.14]
1.1
[0.55]
0.89
0.26
[0.52]
0.47
0.24
[0.16]
0.24
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
Mass (g) Note 2)
Grommet L plug connector, W
M plug connector M8 connector
84 (50) 85 (53) 89 (57)
102 (68) 107 (73) 115 (81)
104 (69) 109 (74) 117 (82)
Series SY5000
Valve model
Type of
actuation
Flow characteristics Note 1)
Port
size
1 4/2 (P A/B)
4/2 5/3 (A/B EA/EB)
C (dm3/(s·bar)) b
Cv C (dm3/(s·bar)) b
Cv
2 Single
position Double
2.4 0.41 0.64 2.8 0.29 0.66
Closed center
1.8 0.47 0.50 1.8 0.40 0.47
SY5„40-„-02
Exhaust 1 4
3
position
center
1.4
0.55
0.44
3.0 0.33 0.72
[1.2] [0.48] [0.37]
Pressure
center
3.3 0.36 0.85
[0.84] [0.60] [0.28]
1.8
0.40
0.48
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
Grommet
121 (58)
139 (76)
144 (82)
Mass (g) Note 2)
L plug connector,
M plug connector
DIN terminal
W
M8 connector
123 (61) 154 (92) 127 (65)
144 (81) 186 (123) 152 (89)
150 (87) 192 (129) 158 (95)
Series SY7000
Valve model
Type of
actuation
Flow characteristics Note 1)
Port
size
1 4/2 (P A/B)
4/2 5/3 (A/B EA/EB)
C (dm3/(s·bar)) b
Cv C (dm3/(s·bar)) b
Cv
2 Single
position Double
4.1 0.41 1.1 4.1 0.29 1.0
Closed center
3.0 0.43 0.80 2.6 0.41 0.72
SY7„40-„-02
Exhaust
3
position
center
Pressure
center
14
2.6
0.42
0.71
4.7 0.35 1.1
[1.7] [0.48] [0.49]
5.3 0.39 1.3
[2.3] [0.49] [0.65]
2.2
0.49
0.63
2 Single
position Double
4.9 0.29 1.2 4.5 0.27 1.1
Closed center
3.0 0.40 0.80 2.6 0.45 0.73
SY7„40-„-03
Exhaust
3
position
center
Pressure
center
38
2.6
0.42
0.71
4.8 0.35 1.1
[1.7] [0.48] [0.49]
5.3 0.31 1.3
[2.3] [0.51] [0.64]
2.3
0.45
0.66
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
Grommet
218 (89)
237 (108)
239 (110)
218 (89)
237 (108)
239 (110)
Mass (g) Note 2)
L plug connector,
M plug connector
DIN
terminal
M8
W
connector
221 (92) 242 (113) 225 (96)
242 (113) 284 (155) 250 (121)
245 (116) 287 (158) 253 (124)
221 (92) 242 (113) 225 (96)
242 (113) 284 (155) 250 (121)
245 (116) 287 (158) 253 (124)
Series SY9000
Valve model
Type of
actuation
Flow characteristics Note1)
Port 1 4/2 (P A/B)
size C (dm3/(s·bar)) b
Cv
4/2 5/3 (A/B EA/EB)
C (dm3/(s·bar)) b
Cv
2 Single
position Double
7.9 0.34 2.0 9.6 0.43 2.6
Closed center
7.5 0.33 1.8 7.3 0.30 1.7
SY9„40-„-03
3
Exhaust
center
position
Pressure
center
38
7.2
0.34
1.7
13 0.23 2.8
[4.0] [0.41] [0.95]
12 0.26 2.8
[3.3] [0.41] [0.84]
6.7
0.40
1.9
2 Single
position Double
8.0 0.48 2.2 10 0.29 2.5
Closed center
SY9„40-„-04
Exhaust
3 center
position
Pressure
center
12
7.6 0.32 1.8 7.3 0.32 1.8
7.3
0.42
2.0
13 0.32 3.6
[4.7] [0.54] [1.5]
12 0.33 3.3
[3.3] [0.51] [0.94]
7.4
0.33
1.9
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
Mass (g) Note 2)
Grommet
L plug connector,
M plug connector
DIN
terminal
M8
W
connector
469(172) 472(175) 493(196) 476(179)
488(191) 494(197) 535(239) 502(205)
512(215) 518(221) 560(263) 526(229)
448 (172) 453 (175) 472 457(179)
467 (191) 473 (197) 515 481(205)
491 (215) 497 (221) 539 505(229)
128


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Base Mounted Series SY3000/5000/7000/9000
Construction
Series SY
JIS Symbol
2 position single
2 position single
JIS Symbol
2 position double
42
(A) (B)
513
(EA) (P) (EB)
2 position double
JIS Symbol
3 position closed center
42
(A) (B)
513
(EA) (P) (EB)
3 position closed center / exhaust center / pressure center
3 position exhaust center
3 position pressure center
42
(A) (B)
513
(EA) (P) (EB)
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
Component Parts
No. Description
1 Body
Material
Aluminum die-casted
(SY3000: Zinc die-casted)
2 Adapter plate
Resin
3 End plate
Resin
4 Piston
Resin
5 Spool valve assembly Aluminum, H-NBR
(This figure shows a closed center type.)
Note
White
White
(SY9000: Gray)
White
Replacement Parts
No. Description
SY3„40
Part No.
SY5„40
SY7„40
SY9„40
6 Sub-plate Note)
SY3000-27-1
(-Q)
SY5000-27-1
(-Q)
1
3
4: SY7000-27-1
8: SY7000-27-2
(-Q)
(-Q)
38:
1 2:
SY9000-27-1
SY9000-27-2
(-Q)
(-Q)
7 Pilot valve assembly
Refer to “How to Order Pilot Valve Assembly” on page 130.
8 Gasket
SY3000-11-25
SY5000-11-15
SY7000-11-11
SY9000-11-2
Round head
combination screw
SY3000-23-4
(M2 x 21)
M3 x 26
M4 x 31
SY9000-18-2
(M3 x 42)
Thread type
Note) For CE-compliant, suffix “Q” at the end of part no.
Note
Aluminum
die-casted
H-NBR
For valve mounting
(Matt nickel plated)
Caution
Mounting screw
tightening torques
M2: 0.16 N·m
M3: 0.8 N·m
M4: 1.4 N·m
129


I-SY5220 Datasheet PDF
No Preview Available !

Click to Download PDF File

Series SY3000/5000/7000/9000
How to Order Pilot Valve Assembly
V111 5 G
Coil specifications
Nil Standard
With power saving circuit
T (24 VDC, 12 VDC only)
Power saving circuit
is not available in
the case of D, DO
or W„ type.
Rated voltage
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
1 100 VAC 50 60 Hz
2 200 VAC 50 60 Hz
3
110 VAC 50 60 Hz
[115 VAC 50 60 Hz]
4
220 VAC 50 60 Hz
[230 VAC 50 60 Hz]
For type W„, DC
voltage is only
available.
CE-compliant: For
DC only.
Light/surge voltage suppressor
Nil Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
For “R” and “U”, DC voltage is only available.
Power saving circuit is only available in the “Z” type.
Electrical entry
G Grommet, 300 mm lead wire
H Grommet, 600 mm lead wire
L
LN
L plug
connector
LO
With lead wire
Without lead wire
Without connector
M
MN
M plug
connector
MO
WO M8
W„ connector
With lead wire
Without lead wire
Without connector
Without connector cable
With connector cable Note 1)
For connector cable of M8 connector,
refer to page 339.
Note 1) Enter the cable length symbols in
„. Please be sure to fill in the blank
referring to page 340.
í DIN terminal type
V115 5 D
Rated voltage
5 24 VDC
6 12 VDC
1 100 VAC 50 60 Hz
2 200 VAC 50 60 Hz
3
110 VAC 50 60Hz
[115 VAC 50 60Hz]
4
220 VAC 50 60Hz
[230 VAC 50 60Hz]
DC specifications
of type D, Y, DO
and YO is only
available with 12
and 24 VDC.
Light/surge voltage suppressor
Nil Without light/surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
Z With light/surge voltage suppressor (Non-polar type)
DOZ and YOZ are not available.
For AC voltage valves there is no “S” option. It
is already built-in to the rectifier circuit.
Electrical entry
D DIN
terminal
DO (Type D)
With connector
Without connector
Y DIN
terminal
YO (Type Y)
With connector
Without connector
Note) Do not replace V111
(G, H, L, M) to V115
(DIN terminal) and
vice versa when
replacing pilot valve
assembly only.
Note) Since V111 and V115 are CE-compliant as
standard, the suffix “-Q” is not necessary.
130



Click to Download PDF File