Hall Effect Current Sensors S23P***D15 Series
Features:
• • • • • • Closed Loop type Current or voltage output Conversio...
Hall Effect Current Sensors S23P***D15 Series
Features:
Closed Loop type Current or
voltage output Conversion ratio K = 1:2000 Printed circuit board mounting Integrated primary Insulated plastic case according to UL94V0
Advantage:
Excellent accuracy and linearity Low temperature drift Wide frequency bandwidth No insertion loss High Immunity to external interferences Optimised response time Current overload capability
TA=25ºC, VCC=±15V
Specifications
Parameters
Rated Current Maximum Current
1
Symbol If 50A ±110A (@ RM≤71Ω)
S23P50/100D15 100A ±160A (@ RM≤25Ω) 0Ω~57Ω @ VCC = ±12V 45Ω~114Ω @ VCC = ±15V 1 : 2000 ±50mA ±0.15mA @ If=0A IOUT ±0.25% ±0.15% @ If ±15V (±11.4V~±16V) ±16mA (Output Current is not included) < 1.0µs @ di/dt = 100A / µs ±0.01%/ºC @ If < ±0.5mA typ. @ If = 0A (-40ºC~+85ºC) ≤ 0.3mA (0A ⇔ If) AC5000V, for 1minute (sensing current 0.5mA), Primary ⇔ Secondary > 500MΩ (@ DC500V) Primary ⇔ Secondary DC .. 200 kHz 115Ω @ TA = 70ºC 121Ω @ TA = 85ºC –40ºC ~ +85ºC –40ºC ~ +90ºC
3
Ifmax
RM K IOUT IOE X
Measuring resistance If = ±ADC @ 85°C Conversion Ratio Output Current Offset Current Output Current Accuracy Output Linearity Supply
Voltage
2
0Ω~217Ω @ VCC = ±12V 0Ω~327Ω @ VCC = ±15V 1 : 2000 ±25mA
εL
VCC ICC
Consumption Current Response Time
3
tr
TCIOUT TCIOE IOH Vd RIS f RS TA TS
2