Preliminary
QRE2412001 120 Amp/Phase
Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (724) 925-7272
3 Pha...
Preliminary
QRE2412001 120 Amp/Phase
Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (724) 925-7272
3 Phase Diode Bridge Module 120 Amp/Phase Up to 2400 Volts
A E E
Description:
Powerex 3 Phase Diode Modules are designed for use in applications requiring rectification and isolated packaging. The modules are isolated for easy mounting with other components on a common heatsink.
T3
F C F T1 T2
TOP
Features:
n Electrically Isolated Heatsinking
D SIDE
n Metal Baseplate n Low Thermal Impedance for Improved Current Capability n UL Recognized
Applications:
T1 T2 T3
n Battery Supplies n Bridge Circuits n AC & DC Motor Control n Rectifiers
Dimensions
Dimension A B C D E F GO / Note: Dimensions are for reference only. 5.12 1.50 130 38 Inches Min. Max. 5.51 Metric Min. Max. 140
Preliminary
Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (724) 925-7272
QRE2412001 120 Amp/Phase
QRD2412002 TM 3 Phase Diode Bridge POW-R-BLOK Modules
120 Amperes /Phase Up to 2400 Volts
Absolute Maximum Ratings
Characteristics Repetitive Peak Reverse Blocking
Voltage Non-Repetitive Peak Reverse Blocking
Voltage RMS Forward Current/Phase Average Forward Current/Phase Peak Half Cycle Non-Repetitive Surge Current/Phase Peak Half Cycle Non-Repetitive Surge Current/Phase I t for Fusing for One Cycle I t for Fusing for One Cycle Operating Junction Temperature Storage Temperature Maximum Mounting Torque, M6 Mounting Screw Maximum Terminal Torque, M8 Terminal Screw Module Weigh...