2,500 V - 10,000 V Rectifiers
1.5 A - 3.0 A Forward Current 3000 ns Recovery Time
AXIAL LEADED EPOXY MOLDED
K25S K50S K...
2,500 V - 10,000 V Rectifiers
1.5 A - 3.0 A Forward Current 3000 ns Recovery Time
AXIAL LEADED EPOXY MOLDED
K25S K50S K100S
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Working Reverse
Voltage (Vrwm) Average Rectified Current (Io) 55°C(1) Volts K25S K50S K100S Amps 100°C(2) Amps 25°C µA Reverse Current @ Vrwm (Ir) 100°C µA 25°C Volts Amps Foward
Voltage (Vf) 1 Cycle Repetitive Reverse Surge Surge Recovery Current Current Time tp=8.3ms (3) (Ifsm) (Ifrm) (Trr) 25°C Amps 25°C Amps 25°C ns Thermal Impedance Junction Cap. @50VDC @ 1kHZ (Cj)
5
uJ-L
L=.000 L=.250 °C/W °C/W
pF
2500 5000 10000
3.00 2.20 1.50
1.50 1.10 0.75
2.0 2.0 2.0
100 100 100
5.5 8.5 12.0
3.0 2.2 1.5
200 150 100
50 35 25
3000 3000 3000
2 2 2
4.5 4.5 4.5
70 50 35
(1)TL=55°C L=0.375" (2)TL=100°C L=0.375" (3)If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55°C to +150°C Stg. Temp.= -55°C to +175°C
.250 ±.015 (6.35 ±.38)
.375 ±.015 (9.53 ±.38)
.40(10.16) MIN.
.093 ±.003 (2.36 ±.06)
Dimensions: In. (mm) All temperatures are ambient unless otherwise noted. Data subject to change without notice.
VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291
TEL 559-651-1402 FAX 559-651-0740 www.
voltagemultipliers.com
131
K25S K50S K100S
POWER DERATING
40.0
Maximum Power Dissipation (W) Maxumum
4.0 3.5 Forward
Voltage (V) 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 25 50 75 100 125 Lead Temperature Temperature (°C) (C) 150 175 0.0
TYPICAL FORWARD
VOLTAGE VS. FORWARD CURRENT AT 25°C
35.0 30.0...