www.DataSheet4U.com
Bulletin PD-21047 05/05
IRUD400CW60
FRED TM
Features • Ultrafast Recovery • Lead-Free Benefits • •...
www.DataSheet4U.com
Bulletin PD-21047 05/05
IRUD400CW60
FRED TM
Features Ultrafast Recovery Lead-Free Benefits Reduced RFI and EMI Higher Frequency Operation Reduced Snubbing Reduced Parts Count
LUG TERMINAL ANODE 1 LUG TERMINAL ANODE 2
Ultrafast, Soft Recovery Diode
VR = 600V IF(AV) = 400A
BASE COMMON CATHODE
Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are significant portion of the total losses.
Absolute Maximum Ratings Parameters (*)
VR IF(AV) Cathode-to-Anode
Voltage Continuous Forward Current @ TC = 25°C @ TC = 85°C @ TC = 97°C IFSM PD Single Pulse Forward Current Maximum Power Dissipation @ TC = 25°C @ TC = 97°C
Max
600 330 230 200 1200 660 280
Units
V A
W
Case Styles
IRUD400CW60
TO-244
(*) Per Leg unless otherwise specified
1
IRUD400CW60
Bulletin PD-21047 05/05
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameters
VBR VFM Breakdown
Voltage, Forward
Voltage
Min Typ Max Units Test Conditions
600 1.45 1.67 1.13 1.39 0.3 5 2.0 2.3 1.4 1.8 1.38 mA nH V IR = 100µA IF = 200A IF = 400A IF = 200A @ TJ = 150°C IF = 400A @ TJ = 150°C TJ = 150°C, VR = VR Rated from top of terminal hole to mounting plane
IRM LS
Reverse Leakage Current Series ...