Deuterium-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition rates, in parallel for switching higher powers, or for switching long pulses. A reservoir operating from the cathode heater supply is incorporated. The tube is flange mounted with flexible lead connections. Peak forward anode
voltage ............................. 33 kV max Peak anode current (see page 2) ....................... 1.0 kA max Average anode current ....................................... 1.25 A max
GENERAL
Electrical
Cathode (connected internally to mid-point of heater) ..................................oxide coated + 0.2 Heater
voltage ...............................................6.3 V − 0.3 Heater current................................................... 22 A Tube heating time (minimum) ............................. 5.0 min Inter-electrode capacitances (approximate): anode to grid 2 (grid 1 and cathode not connected) ............................ 13 pF anode to grid 1 (grid 2 and cathode not connected) .............................. 7.5 pF anode to cathode (grid 1 and grid 2 not connected)................................ 26 pF
Mechanical
Overall length........................301.0 mm (11.850 inches) max Overall diameter .....................84.12 mm (3.312 inches) max Net weight................................... 0....