25W Single Output AC Dimmable LED Power Supply Features : PCD-25 series AC phase-cut dimming Work with leading edge and trailing edge TRIAC dimmers 115VAC or 230VAC models available Built-in active PFC function Constant current design Protections: Short circuit / Over temperature Cooling by free air convection Fully isolated plastic case IP30 design Class power unit, no FG Class 2 power unit Suitable for indoor LED lighting applications 100% full load burn-in test Low cost High reliability 3 years warranty F 110 ( for B type only) ( for B type only) SELV IP30 ( for A type only) ( for PCD-25-350/700 ) ( except PCD-25-350/700 ) ( for B type only) PCD-25-350 A A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC.
SPECIFICATION MODEL RATED CURRENT CURRENT RANGE OUTPUT CURRENT ACCURACY RATED POWER PCD-25-350 350mA 0 ~ 350mA 5.
0% 20.
3W 25.
2W 2.
7Vp-p 50V www.
DataSheet.
co.
kr PCD-25-700 700mA 24 ~ 36V 0 ~ 700mA PCD-25-1050 1050mA 16 ~ 24V 0 ~ 1050mA 25.
2W 2.
2Vp-p 35V PCD-25-1400 1400mA 12 ~ 18V 0 ~ 1400mA 25.
2W 2Vp-p 25V OPERATING VOLTAGE RANGE 40 ~ 58V RIPPLE & NOISE (max.
) Note.
1 4.
6Vp-p NO LOAD OUTPUT VOLTAGE (max.
) 63V SETUP TIME FREQUENCY RANGE POWER FACTOR (Typ.
) INPUT EFFICIENCY (Typ.
) AC CURRENT (Typ.
) INRUSH CURRENT(max.
) LEAKAGE CURRENT SHORT CIRCUIT PROTECTION OVER TEMPERATURE WORKING TEMP.
WORKING HUMIDITY ENVIRONMENT STORAGE TEMP.
, HUMIDITY TEMP.
COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 1000ms / 230VAC 2000ms / 115VAC at full load 47 ~ 63Hz PF>0.
9/115VAC, PF>0.
9/230VAC, PF>0.
9/277VAC at full load (Please refer to "Power Factor Characteristic" curve) 82% 0.
6A/115VAC 40A/230VAC 0.
3A/230VAC 81% 80.
5% 80% <0.
5mA / 240VAC Hiccup mode, recovers automatically after fault condition is removed.
95 10 (RTH1) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +60 -40 ~ +80 0.
03%/ (Refer to "Derating Curve") , 10 ~ 95% R...