FAST RECOVERY GLASS PASSIVATED RECTIFIER (VOLTAGE RANGE 50 to 800 Volts CURRENT 8.0 Amperes) - Rectron
Description
RECTRON
SEMICONDUCTOR
TECHNICAL SPECIFICATION
FR801S THRU FR806S
FAST RECOVERY GLASS PASSIVATED RECTIFIER
VOLTAGE RANGE 50 to 800 Volts CURRENT 8.
0 Amperes
FEATURES
* * * * * * Fast switching Low leakage Low forward voltage drop High current capability High surge capability High reliability
D2PAK
.
05 (1.
27 REF.
)
MECHANICAL DATA
* * * * * * Case: D2PAK molded plastic Epoxy: Device has UL flammability classification 94V-O Lead: MIL-STD-202E method 208C guaranteed Mounting position: Any Weight: 2.
2 grams Polarity: As marking
.
185 (4.
70) .
177 (4.
50) .
051 (1.
29) .
049 (1.
25)
.
343 (8.
70) .
335 (8.
50)
.
624 (15.
84) .
576 (14.
64)
.
151 (3.
84) .
143 (3.
64)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
o
.
200 (5.
08)
.
401 (10.
19) .
399 (10.
13)
.
015 (0.
381)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25 oC unless otherwise noted) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T C = 75oC Peak Forward Surge Current 8.
3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 3) Typical Junction Capacitance (Note 2) Operating and Storage Temperature Range SYMBOL VRRM VRMS VDC IO I FSM RθJC CJ T J , T STG FR801S 50 35 50 FR802S 100 70 100 FR803S 200 140 200 8.
0 200 3 50 -65 to + 150 FR804S 400 280 400 FR805S 600 420 600 FR806S 800 560 800 UNITS Volts Volts Volts Amps Amps
0
.
065 (1.
65)
.
052 (1.
32) .
048 (1.
22) .
032 (0.
81)
.
043 (1.
10)
C/ W pF
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 8.
0A DC Maximum DC Reverse Current at Rated DC Blocking Voltage TA = 25 oC Maximum Full Load Reverse Current Average, Full Cycle at T C = 100 oC Maximum Reverse Recovery Time (Note 1) NOT...
Similar Datasheet