Datasheet
EARTH LEAKAGE CURRENT DETECTOR
EARTH LEAKAGE CURRENT DETECTOR IC
BD9582F, BD9582N
●General Description
BD9582F/BD9582N integrates leakage detector and amplifier. Especially, it is suitable for high sensitivity and a highspeed operation use, and since the operating temperature range is wide, it can be used for various uses.
●Key Specifications
■ Operating supply voltage range:
12V to 22V
■ Operating temperature range: -20°C to +95°C
■ Supply current:
330μA(typ. )
■ Trip voltage:
4. 92mV to 11. 06mV
■ Output current ability(Ta=-20℃): -200μA~(min. )
●Features
■ Small temperature fluctuation and high input sensitivity
■ Wide operating temperature range
●Packages
SOP8 SIP8
W(Typ. ) x D(Typ. ) x H(Max. )
5. 00mm x 6. 20mm x 1. 71mm 19. 30mm x 10. 50mm x 3. 00mm
●Applications
■ Earth leakage circuit breaker ■ Earth leakage circuit relay
●Typical Application Circuit Example RVS CVS VZ
8 VS
SCR COS
7 OS
6 NR
5 SC
Referenc...