Detailed Description ZMPT101B(ZMPT107) voltage transformer operating guide 1、Wiring diagram FigureⅠ Figure Ⅱ 2、Determination of maximum ou...
Datasheet PDF File ZMPT107 PDF File

ZMPT107
ZMPT107


Overview
ZMPT101B(ZMPT107) voltage transformer operating guide 1、Wiring diagram FigureⅠ Figure Ⅱ 2、Determination of maximum output rms voltage Umax: Umax is decided by the AD peak voltage in the sampling loop in principle.
Peakvoltag e As for Bipolar AD,Umax= 2 peak voltage As for unipolar AD,Umax= 2 2 for example: As for ± 5V AD,the maximum rms voltage of the transformer: Umax = 5V / 2 =3.
53V As for 0~3.
3V AD,the maximum rms voltage of the transformer:V max = 3.
3V / 2 2 =1.
16V 3、Determination of input current-limiting resistor R′ Current-limiting resistor R′= V I V:Rated input voltage I : Rated operating current ( when Coil resistance is compared with current-limiting resistor R′ , it can ...