Home >> OA5669 Search >> ETC OA5669 Datasheet

OA5669 Datasheet

Safety relay

No Preview Available !

OA5669 pdf
Safety relay
OA / OW 5669
according to EN 50 205, IEC/EN 60 255,
IEC 60 664-1
with positively driven contacts
wash proof model as option
double and reinforced insultaion between
contact sets according to EN 50 178
low rated power consumption
high mechanical service life
compact size, small height
Approvals: UL, CSA,
TÜV approval: R 9012316
Applications:
ZH1/457 press controls
Switchgear for safety technology
OA / OW 5669
Technical data
Relay type
1. 0 Relay coil
1. 1 Nominal voltage
1. 2 Nominal consumption
DC V
W
OA 5669
5, 6, 12, 20, 24, 48, 60, 110
0,7
2. 0 Contacts
2. 1 Contact arrangement
1 NC / 1NO
2 changeover contacts, 1 No and 1 changeover contact
2. 2 Contact material
AgCdO + 0,2 µm Au; AgNi 10 + 0,2 µm Au optionally + 5 µm Au
2. 3 Rated insulation voltage
AC V
250
Switching voltage min./max.
V
AC/DC 10 / DC 250, AC 400 (AC/DC 100 mV / 60 V) 1)
2. 4 Limiting continuous current
A
2 x 5 (see operating voltage limit curve)
Switching current min./max.
A
10mA3) / 8 (1 mA / 0,3 A)1)
2. 5 Switching power min./max.
VA
3 / 2 000 (1 mVA / 7 VA)1)
www.DataSheetS4Uw.ictcohming power min./max.
2. 6 Switching capacity
W
3 / 200 (1 mW / 7 W) 1) (s. limit curve for arc-free operation)
to IEC/EN 60 947-5-1 AC 15 AC V/A
NC: 230 / 1
NO: 230 / 3
DC 13 DC V/A
NC: 24 / 2
NO: 24 / 2
2. 7 Electrical life 2)
at 1 s On, 1 s Off (s. contacts service life)
AC 230 V 6 A cos ϕ = 1 switching cycles
> 1 x 105 AgNi 10 > 2 x 105 AgCdO
2. 8 Switching frequency max. switching cycles / s
10
2. 9 Response time / Release time ms
15 / 12
2.10 Contact force NO / NC
cN
10 / 8
3. 0 Other
3. 1 Mechanical life
switching cycles
3. 2 Temperature range
°C
3. 3 Degree of protection, housing
3. 4 Housing
3. 5 Vibration resistance
3. 6 Climate resistance
3. 8 Insolation according to IEC 60 664-1, EN 50 178
Rated insulation voltage
AC V
Contamination level
Overvoltage category
50 x 106
- 40 ... + 60 mounted without distance (Ith = 2 x 5 A)
IP40 / IP67 IEC/EN 60 529 wash proof
Thermoplast GF, PA
10 ... 55 Hz; 0,35 mm amplitude; 5 g max. IEC/EN 60 068-2-6
40 / 060 / 04 (climate category); A/B/D IEC/EN 60 068-1
double and reinforced insulation
250
2
III
1) Values for AgNi 10-contacts + 5 µm Au
2) 10 A total current at t = 20°C and coil voltage UN
All technical data in this list relate to the state at the moment of edition.
We reserve the right for technical improvements and changes at any time.
3) Typical values
OA/ OW 5669 / 25.02.03 d
ETC
ETC



   PDF Click to Download PDF File

   PDF View for Mobile





Related Start with OA566*

[ OA5669 ETC ]     [ OA5611 ETC ]     [ OA5612 ETC ]     [ OA5669 ETC ]    


Searches related to OA5669 part

Find Chips CBC RS online RUTRONIK 24
Component Distributors NexGen Digital Richardson RFPD ICC
Beyond Components NAC PEI-Genesis Powell Electronics
TME Ameya 360 Power & Signal Datasheets360
Freelance Electronics Sager Electronics Terminals & Connectors TTI

0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z
@ 2014 :: DatasheetsPDF.com :: Semiconductors Datasheet Search & Download Site